BACKGROUNDChina has not yet incorporated routine human T‐lymphotropic virus (HTLV)‐1/2 blood donor screening, even though HTLV has been reported in the southeastern coastal region. This study was conducted to investigate the prevalence of HTLV in five major regions across of China.METHODSFrom January 2016 to December 2017, blood samples were collected in 20 blood centers located in different regions of China. These samples were screened for HTLV‐1/2 antibodies using enzyme‐linked immunosorbent assay (ELISA). If the test samples were reactive, the samples were confirmed with a western blot (WB) assay. If the results of WB were indeterminate, the donor was interviewed after a minimum lapse of 8 weeks. All follow‐up samples from donors were tested for anti–HTLV‐1/2 with ELISA and WB.RESULTSThere were 875,453 donor samples tested for anti–HTLV‐1/2 by ELISA. In all, 365 samples tested negative, 22 samples tested positive by WB, and 14 samples with HTLV status undetermined due to being lost to follow‐up. The prevalences were 11.09, 5.96, 3.16, 2.88 and 0.98 per 100,000 in Xiamen, Changsha, Beijing, Shenzhen, and Nanjing blood center, respectively. The prevalences were 0 per 100,000 for all 15 other blood centers. There was significant differences in the prevalence of HTLV in different regions of China (p = 0.0011).CONCLUSIONIn China, HTLV‐1 confirmed positive donors are mainly from southeastern coastal areas. It may be necessary to conduct HTLV screening in these areas to reduce the risk of transfusion‐transmitted HTLV.
OBJECTIVE To evaluate the necessity and suitability of the anti-HCV ELISA teot gray zone setted up by 7 blood station laboratories. METHODS 7 blood station laboratories were coded as 1, 2, 3, 4, 5, 6 and 7 respectively; 8 kinds of ELISA reagents were coded as A, B, C, D, E, F, G and H respectively. 1 or 2 of 8 ELISA reagents produced by different manufactories were used to detect the anti-HCV in specimens of same group by 7 blood station laboratories; the Westen blot was used to detect the specimens with difference of detected results so as to difine the serological status of specimens. The true positive rate of specimens detected by laboratories and gray zone-comfirined positive rate of specimens were accounted so as to analyze the necessity of setting up the gray zone for anti-HCV ELISA test of 7 blood station laboratories; the optimal cut-off value for anti-HCV ELISA test was determined in 7 blood station laborafories by ROC curve and the changes of sensitivity and specificity of 3 different cut-off value(laboratory work cut-off value, manifactory-recommended cun-off value and optimal cut-off value) were compared so as to analyze the suitability of gray zone for anti-HCV ELISA test in 7 blood station laboratories. RESULTS The true positive rate detected by 7 blood station laboratories, out of which coded 1 laboratory used 2 kinds of coded A, B reagents was 95.40%(1A), 99.23% (1B), 94.25% (2C), 96.17% (3D), 98.08% (4E), 96.93% (5F), 97.32%(6G) and 93.10%(7H). Except for 2C(94.25%) and 7H(93.10%), the true positive rate detected by laboratoies which not sutted up gray zone, the gray zone-con-firmed positive rate in 6 blood station laboratories setted up gray zone: was 0.00%, 0.00%, 21.43%, 0.00%, 0.00%, 0.00% and 38.89%. The comparison of 3 different cut-off valuces by ROC curve showed that the anti-HCV cut-off values in 5 laboratories(1B, 2C, 4E, 5F and 6G) were as follows: optimal cut-off value>manufactory recommeded cut-off value>laboratory work cut-off value, thus use of manufactory-recommeded cut-off value abreadly has reached the high sensitivity requinements for laboratory screening; however, the optimal cut-off value in laboratories 1A, 3B and 7H, thas the appropriate gray zone should be used. In 6 laboratories setting up gray zone, the gensitivity in 3D, 7H laboratories only a little improved (1.60% and 2.70% raspectively) in Eamparison between laboratory work cut-off value and manufactorg-recommeded cut-off value; moreover, the sensitivity in other laboratories not is changed, but the specificity decreased (0.20%-0.50%). CONCLUSION In addition to setting up the appropriate gray zone in laboratories 1A, 3D and 5H, the gray zone in other laboratories may be cancelled. Even in the same laboratory, the setting up the gray zone also should be scientifically assessed, the same scale cannot be blindly used, thus appropniate strategies should be established.
•We reviewed literatures and conducted study among blood donors in 9 provinces.•HTLV screen in China can be divided into three ten-year periods.•We also found an inner family transmission case.•China is a low HTLV-1 endemic area with however some regions with a higher rate.•Urgent to perform more investigations to develop strategies toward HTLV infection.