The performance of a sequencing batch biofilter granular reactor (SBBGR), followed by a dual media granular activated carbon (GAC) column, was evaluated in terms of its ability to remove selected per- and polyfluoroalkyl substances (PFAS) from landfill leachate. The results show that the SBBGR achieved an overall reduction of 51%, with the preferential removal of long-chain PFAS, while short-chain PFAS were only partially removed. Subsequent GAC treatment exhibited compound-specific breakthrough behavior, which was governed by chain length. Short-chain PFAS (e.g., perfluorobutanoic acid) exhibited rapid bed volumes at 50% breakthrough (BV50 ≈ 88), whereas long-chain PFAS (e.g., perfluorooctanoic acid and perfluorooctanesulfonic acid) were substantially more retained (BV50 ≈ 446 and 361, respectively), with perfluorohexanesulfonic acid and perfluorodecanoic acid failing to reach BV50 within the monitored period. Mass balance analysis showed that the hybrid GAC column captured ~73% of the influent PFAS mass. This resulted in >80–95% retention of long-chain PFAS and <40% retention of short-chain PFAS. Although long-chain PFAS were preferentially adsorbed, mobile short-chain species dominated residual effluent loads. These findings highlight the need for optimized contact times or dual-media strategies to control the breakthrough of short-chain PFAS.
This study evaluates the long-term performance of the MULESL (MUch LEss SLudge) system for treating municipal wastewater intended for agricultural reuse, with particular focus on contaminants of emerging concern (CECs). The system showed stable removal of conventional pollutants under variable hydraulic loads, achieving 94% and 90% reductions in total and soluble COD, respectively, with residual BOD5 of 9 mg L-1. High removal efficiencies were also observed for TSS (>94%), VSS (>93%), TN (83%), TKN (91%), and NH3 (92%), while pH and conductivity remained within regulatory limits. From a database of over 40 000 compounds, 46 CECs were selected as the most abundant in influent wastewater; metformin, caffeine, and 1,7-dimethylxanthine were the most prevalent. The MULESL system achieved up to 85% overall CEC removal. Post-treatment significantly improved microbiological quality: UV disinfection (20 s) reduced E. coli to <10 CFU/100 mL, meeting stringent European reuse standards, while peracetic acid (2-3 mg L-1) provided slightly lower but effective results. The high efficiency is attributed to the biofilm-granular structure, long solids retention time, and enhanced sorption and biodegradation processes, highlighting the MULESL system as a compact and resilient solution for safe wastewater reuse.
This study compared the effectiveness of the Sequencing Batch Biofilter Granular Reactor (SBBGR) plant with and without the integration of ozone (BIO-CHEM process) in the remediation of medium-aged landfill leachate. Special attention is given to the removal of per- and polyfluoroalkyl substances (PFAS) as a group of bioaccumulative and persistent pollutants. The findings highlight the high SBBGR performance under biological process only for key wastewater contaminants, with 82% for chemical oxygen demand (COD), 86% for total nitrogen, and 98% for ammonia. Moderate removal was observed for total (TSS) and volatile (VSS) suspended solids (41% and 44%, respectively), while phosphorus and colour removal remained limited. Remarkably, the SBBGR process achieved complete removal of long-chain PFAS, while its performance declined for shorter-chain PFAS. BIO-CHEM process significantly improved COD (87.7%), TSS (84.6%), VSS (86.7%), and colour (92–96%) removal. Conversely, ozonation led to an unexpected increase in the concentrations of several PFAS in the effluent, suggesting ozone-induced desorption from the biomass. SBBGR treatment was characterised by a low specific sludge production (SSP) value, i.e., 5–6 times less than that of conventional biological processes. SSP was further reduced during the application of the BIO-CHEM process. A key finding of this study is a critical challenge for PFAS removal in this combined treatment approach, different from other ozone-based methods.
The present study investigated a Sequencing Batch Biofilter Granular Reactor (SBBGR) for treating four landfill leachate stocks with varying per- and poly-fluoroalkyl substances (PFAS) concentrations. The SBBGR, characterized by a very long sludge retention time, effectively removed conventional pollutants: 5 days-biochemical oxygen demand (99.93 %-100 %), total nitrogen (44 %-88 %), ammonia (64 %-99.8 %), and total/volatile suspended solids (70-96 % and 75-95 % respectively). However, chemical oxygen demand removal was moderate due to the high content of biorefractory compounds in all leachate stocks. The analysis showed that total PFAS,2 concentration, calculated as the sum of concentrations of the 12 analysed PFAS, varied across the four leachate stocks, with stock 4 having the highest concentration (about 5.5 mg L-1). The removal efficiency of total PFAS,2 significantly improved over the course of SBBGR operation, increasing from 32 % to 94 % when treating stock 4. This improvement was attributed to continuous microbial consortium selection and increased biomass age. A notable strength of the SBBGR was its efficacy in removing long-chain PFASs, which exhibit greater hydrophobicity and a higher tendency for bioaccumulation compared to short-chain PFASs, which are more water-soluble. The SBBGR system offers a promising approach for PFASs removal due to its effective microbial consortium, high salinity resistance, and potential cost-effectiveness. Environmental implication: PFASs have great relevance in the context of the urban integrated water cycle since they are compounds present in many daily uses in the civil and industrial fields. An important source of PFAS release into the environment is through the leachates, usually disposed at municipal wastewater treatment plants, which are not designed to remove PFAS. The system proposed and tested in the present study offers a promising approach for PFASs removal due to its effective microbial consortium, thereby reducing PFAS release into the environment.
Contaminants of emerging concern, such as pharmaceuticals (PhACs), are continuously introduced into agro-ecosystems through irrigation with treated wastewater (TWW). While this practice is increasingly common in drought regions, only limited information is available on the fate of PhACs within the soil–plant system. For this purpose, a two-year study was conducted by irrigating artichokes, non-inoculated and inoculated with different arbuscular mycorrhizal fungi, with water containing PhACs at different concentrations. The experiment, conducted in both open field and pot conditions, aimed to evaluate their potential accumulation in the soil and plant tissues. Results showed that PhACs concentrations varied according to the physicochemical properties of the compounds and the duration of irrigation. The study revealed minimal accumulation of contaminants in the soil and non-edible plant parts. This was observed only at the end of the second growing cycle, when the plants were irrigated with TWW containing trace PhAC levels. In contrast, during both pot cultivation cycles, PhACs accumulated in the soil were translocated into plant organs when irrigated with water enriched to 200 μg L−1 with eight PhACs. At the end of the trial, climbazole had the highest concentration in soil, while carbamazepine and fluconazole showed greater accumulation across all plant organs compared to other PhACs. In both trials, plants inoculated with Septoglomus viscosum absorbed less PhACs compared to those inoculated with Rhizophagus irregularis + Funneliformis mosseae. These results suggest that, while the long-term use of TWW containing PhACs may improve artichoke yield, it could present different degrees of risk to both environmental and human health, depending on the concentration levels of contaminants.
Per-polyfluoroalkyl substances (PFASs) are a class of persistent organic pollutants that have been detected in several environmental matrices. Photoelectrocatalysis (PEC) was employed to remove PFASs contained in natural groundwater collected in the Veneto region (Italy), where a massive PFAS contamination was present. Nine PFASs were detected and monitored throughout the process. By varying the magnitude of the applied cell voltage (no bias and 4, 6, and 8 V) the optimal condition was assessed to be 4 V, resulting in a total PFAS removal of about 87%. The presence of H2O2 was ineffective on the reaction kinetic, while NaCl inhibited the oxidation of PFASs. The EEO (Electrical Energy per Order of Magnitude) analysis revealed that PEC is more energy-efficient than both traditional photolysis and most advanced oxidation techniques discussed in published research.
Photoelectrocatalysis (PEC) was applied for the degradation of PFASs in natural groundwater collected from two wells located in the Veneto Region (Italy) where a massive contamination of the aquifer was discovered. Out of 48 monitored species, up to 9 PFASs were detected. On average, the degradation rate followed the order: PFOA>PFHpA>PFHxA approximate to PFPeA>PFBA and PFOS>PFHpS; the concentration of PFBS and PFHxS did not change during the tests. The overall PFASs concentration decreased by 63 % in well 1 and by 65 % in well 2. PEC tests of PFOA solutions ([PFOA] = 2 mu g/l; [K2SO4] = 4 mM] induced the transient formation of PFHpA, followed by PFHxA, PFPeA and PFBA, confirming the reaction pathway consisting of decarboxylation followed by a stepwise losing of CF2 units, transiently forming shorter chain intermediates. PEC efficiency was compared to photolysis. According to electrical energy per order of magnitude, PEC outperforms conventional photolysis and most of the other advanced oxidation processes reported in literature.
Nontargeted screening (NTS) utilizing liquid chromatography electrospray ionization high-resolution mass spectrometry (LC/ESI/HRMS) is increasingly used to identify environmental contaminants. Major differences in the ionization efficiency of compounds in ESI/HRMS result in widely varying responses and complicate quantitative analysis. Despite an increasing number of methods for quantification without authentic standards in NTS, the approaches are evaluated on limited and diverse data sets with varying chemical coverage collected on different instruments, complicating an unbiased comparison. In this interlaboratory comparison, organized by the NORMAN Network, we evaluated the accuracy and performance variability of five quantification approaches across 41 NTS methods from 37 laboratories. Three approaches are based on surrogate standard quantification (parent-transformation product, structurally similar or close eluting) and two on predicted ionization efficiencies (RandFor-IE and MLR-IE). Shortly, HPLC grade water, tap water, and surface water spiked with 45 compounds at 2 concentration levels were analyzed together with 41 calibrants at 6 known concentrations by the laboratories using in-house NTS workflows. The accuracy of the approaches was evaluated by comparing the estimated and spiked concentrations across quantification approaches, instrumentation, and laboratories. The RandFor-IE approach performed best with a reported mean prediction error of 15x and over 83% of compounds quantified within 10x error. Despite different instrumentation and workflows, the performance was stable across laboratories and did not depend on the complexity of water matrices.
Abstract Background Prioritisation of chemical pollutants is a major challenge for environmental managers and decision-makers alike, which is essential to help focus the limited resources available for monitoring and mitigation actions on the most relevant chemicals. This study extends the original NORMAN prioritisation scheme beyond target chemicals, presenting the integration of semi-quantitative data from retrospective suspect screening and expansion of existing exposure and risk indicators. The scheme utilises data retrieved automatically from the NORMAN Database System (NDS), including candidate substances for prioritisation, target and suspect screening data, ecotoxicological effect data, physico-chemical data and other properties. Two complementary workflows using target and suspect screening monitoring data are applied to first group the substances into six action categories and then rank the substances using exposure, hazard and risk indicators. The results from the ‘target’ and ‘suspect screening’ workflows can then be combined as multiple lines of evidence to support decision-making on regulatory and research actions. Results As a proof-of-concept, the new scheme was applied to a combined dataset of target and suspect screening data. To this end, > 65,000 substances on the NDS, of which 2579 substances supported by target wastewater monitoring data, were retrospectively screened in 84 effluent wastewater samples, totalling > 11 million data points. The final prioritisation results identified 677 substances as high priority for further actions, 7455 as medium priority and 326 with potentially lower priority for actions. Among the remaining substances, ca. 37,000 substances should be considered of medium priority with uncertainty, while it was not possible to conclude for 19,000 substances due to insufficient information from target monitoring and uncertainty in the identification from suspect screening. A high degree of agreement was observed between the categories assigned via target analysis and suspect screening-based prioritisation. Suspect screening was a valuable complementary approach to target analysis, helping to prioritise thousands of substances that are insufficiently investigated in current monitoring programmes. Conclusions This updated prioritisation workflow responds to the increasing use of suspect screening techniques. It can be adapted to different environmental compartments and can support regulatory obligations, including the identification of specific pollutants in river basins and the marine environments, as well as the confirmation of environmental occurrence levels predicted by modelling tools. Graphical Abstract
In the last decades particular attention is being paid to the efficient and effective removal of compounds of emergingconcern (CECs) present in wastewater before their eventual reuse or disposal. Several technologies have been devel-oped for the degradation of CECs in aqueous matrix, in this regard advanced oxidation processes (AOPs) represent anascent technological solution developed on a laboratory scale with applications on a prototype scale. The experimen-tal evidences have shown that AOPs processes can oxidize numerous organic compounds in a much faster and moreefficient way than that of the most common disinfection processes. The most common AOPs processes are thosethat involve the use of H2O2/UV, O3/UV, H2O2/O3,H2O2/O3/UV, Fenton and photo-Fenton. The aim of this work isto illustrate the results of a comparative LCA study of a laboratory scale UV-C photoreactor for the tertiary treatmentof urban wastewater of three treatment systems (UV-C, UV-C + H2O2e UV-C + TiO2). In particular, the specificobjective is to evaluate, fromanenvironmentalpoint ofview, aninnovative advanced oxidation system based on nano-structures TiO2immobilized on a stainless steel mesh. Compared to the UV-C photolysis reference system, the additionof hydrogen peroxide reduces the total environmental impact of the system by almost 75 %, while the use of thestainless-steel mesh coated by the nanostructures titanium dioxide reduces the UV-C environmental impact by 30 %. These results are due to the lower energy consumption of these last treatments compared to photolysis alone.The main impacts of the three systems are related to the electric power consumption of the centrifugal pump(63-64 %) and of the UV-C lamp (32-33 %). The LCA applied to these systems has shown that TiO2assistedphotocatalysis is not yet advantageous from an environmental point of view and that, therefore, the efficiency ofthe system needs to be improved
Two advanced oxidation processes (AOPs), namely ozone/H2O2 and UV/H2O2, were tested at pilot scale as zero-liquid-discharge alternative treatments for the removal of microbiological (bacteria and viruses), chemical (compounds of emerging concern (CECs)) and genotoxic responses from tertiary municipal wastewater for indirect potable reuse (IPR). The AOP treated effluents were further subjected to granular activated carbon (GAC) adsorption and UV disinfection, following the concept of multiple treatment barriers. As a reference, a consolidated advanced wastewater treatment train consisting of ultrafiltration, UV disinfection, and reverse osmosis (RO) was also employed. The results showed that, for the same electrical energy applied, the ozone/H2O2 treatment was more effective than the UV/H2O2 treatment in removing CECs. Specifically, the ozone/H2O2 treatment, intensified by high pressure and high mixing, achieved an average CECs removal efficiency higher than UV/H2O2 (66.8% with respect to 18.4%). The subsequent GAC adsorption step, applied downstream the AOPs, further improved the removal efficiency of the whole treatment trains, achieving rates of 98.5% and 96.8% for the ozone/H2O2 and UV/H2O2 treatments, respectively. In contrast, the ultrafiltration step of the reference treatment train only achieved a removal percentage of 22.5%, which increased to 99% when reverse osmosis was used as the final step. Microbiological investigations showed that all three wastewater treatment lines displayed good performance in the complete removal of regulated and optional parameters according to both national and the European Directive 2020/2184. Only P. aeruginosa resulted resistant to all treatments with a higher removal by UV/H2O2 when higher UV dose was applied. In addition, E. coli STEC/VTEC and enteric viruses, were found to be completely removed in all tested treatments and no genotoxic activity was detected even after a 1000-fold concentration. The obtained results suggest that the investigated treatments are suitable for groundwater recharge to be used as a potable water source being such a procedure an IPR. The intensified ozone/H2O2 or UV/H2O2 treatments can be conveniently incorporated into a multi-barrier zero-liquid-discharge scheme, thus avoiding the management issues associated with the retentate of the conventional scheme that uses reverse osmosis. By including the chemical cost associated with using 11-12 mg/L of H2O2 in the cost calculations, the overall operational cost (energy plus chemical) required to achieve 50% average CECs removal in tertiary effluent for an hypothetical full-scale plant of 250 m3/h (or 25,000 inhabitants) was 0.183 €/m3 and 0.425 €/m3 for ozone/H2O2 and UV/H2O2 treatment train, respectively.
The fluctuation in the number of people in tourist areas affects the wastewater quality and quantity. Constructed wetlands (CWs) aim to simulate physical, chemical, and biological processes occurring in natural environments for wastewater treatment and are considered a sustainable system. The current study aimed at evaluating the effectiveness of in-vessel CWs for supporting the wastewaters treatment plants in periods of overloading. Such approach can be quickly implementable, economic, and the CWs can be fast regenerated in the framework of sustainable good practices. Three pilot scale CWs were prepared in as many containers layering 10 cm of gravel, 60 cm of sand and 10 cm of gravel, and placing pieces of giant reed rhizomes in the upper layers. The bottom of each CW had a tap, and CWs were irrigated with a real municipal sewage three times a week. Before each new irrigation, the tap was opened, and the effluent collected for determining gross parameters, elemental composition, and contaminants of emerging concern (CECs). CWs significantly reduced almost all gross parameters considered and half the CECs, except for a couple of metabolites of corresponding parental compounds. With regards to the potentially toxic elements, all reduced their concentration from the influents to the effluents. The results of this study were promising and highlighted good efficiency of constructed wetlands as pre-treatment of real municipal sewage to reduce the overloading of the wastewater treatment plant.
In the present study natural deep eutectic solvents (NADES) were investigated as green and sustainable approach for the extraction of Polyfluoroalkyl Substances (PFAS) from aqueous solutions. NADES, derived from natural products, offer environmentally friendly, low-cost, and biodegradable properties. A hydrophobic NADES, menthol-acetic acid, was shown to be able to extract perfluoroheptanoic acid (PFHpA) from water. The extraction efficiency was about 90 % and was not affected by the PFHpA concentration (0.23-350 mg/L) and by the initial pH of the aqueous solution at the tested conditions. After extraction the pH of the aqueous solution dropped to 2.2, due to a partial dissolution of the acetic acid from the NADES. The mechanism of interaction between the PFHpA and the NADES was unraveled using Density Functional Theory (DFT) calculations. These findings highlight the potential of NADES as a green and sustainable solution for PFAS remediation.
The irrigation with treated wastewater is among the main anthropogenic sources for the release of pharmaceuticals (PhACs) into the soils and their translocation into crops, with possible toxic and adverse effects on humans. The arbuscular mycorrhizal fungi (AMF) can be employed for the reduction of organic soil pollutants, even if their efficiency depends on the mycorrhizal fungi, the plant colonized, and the type and concentration of the contaminant. This study aimed to evaluate the uptake of PhACs from wastewaters of different qualities used for the irrigation of mycorrhizal artichoke plants, the presence in their edible parts and the role of the arbuscular mycorrhizal fungi. The research was carried out on artichoke plants not inoculated and inoculated with two different AMF and irrigated with treated wastewater (TW), groundwater (GW) or GW spiked with different and selected PhACs (SGW). The inocula were a crude inoculum of Septoglomus viscosum (MSE) and a commercial inoculum of Glomus intraradices and Glomus mosseae (MSY). The results of the present study showed that carbamazepine and fluconazole were found in the artichoke only with SGW irrigation. The mycorrhizal plants showed a reduction of the pharmaceutical's uptake, and within the AMF, MSE was more effective in preventing their absorption and translocation.
This study explored process synergies attainable by integrating a vacuum ultraviolet-based advanced oxidation process with biofiltration. A comparison using granular activated carbon or granular zeolite as filtration media were examined in context of advanced wastewater treatment for potable reuse. Six biofiltration columns, three with granular activated carbon and three with granular zeolite, were operated in parallel and batch-fed daily with nitrified secondary effluent. After achieving a pseudo-steady state through the filter columns, vacuum ultraviolet treatment was applied as pre-treatment or as post-treatment, at two different applied energies (i.e., VUV-E1=1 kWh/m(3) and VUV-E10=10 kWh/m(3)). Once granular activated carbon had transitioned to biologically activated carbon, as determined based on soluble chemical oxygen demand removal, adsorption was still observed as the main mechanism for contaminants of emerging concern and nitrate removal. Vacuum ultraviolet pre-treatment markedly improved contaminants of emerging concern removal through the integrated system, achieving 40% at VUV-E1 and 90% at VUV-E10. When applied as post-treatment to zeolite column effluents, VUV-E1 and VUV-E10 further increased contaminants of emerging concern removal by 20% and 90%, respectively. In the zeolite system, vacuum ultraviolet pre-treatment also increased soluble chemical oxygen demand removal efficiency, indicating that higher energy vacuum ultraviolet increased biodegradability. Total prokaryotes were two-fold more abundant in biologically activated carbon than in zeolite, with vacuum ultraviolet pretreatment markedly affecting microbial diversity, both in terms of richness and composition. Media type only marginally affected microbial richness in the biofilters but showed a marked impact on structural composition. No clear relationship between compositional structure and depth was observed.
The photocatalytic efficiency of an innovative UV-light catalyst consisting of a mesoporous TiO2 coating on glass fibers was investigated for the degradation of pharmaceuticals (PhACs) in wastewater effluents. Photocatalytic activity of the synthesized material was tested, for the first time, on a secondary wastewater effluent spiked with nine PhACs and the results were compared with the photolysis used as a benchmark treatment. Replicate experiments were performed in a flow reactor equipped with a UV radiation source emitting at 254 nm. Interestingly, the novel photocatalyst led to the increase of the degradation of carbamazepine and trimethoprim (about 2.2 times faster than the photolysis). Several transformation products (TPs) resulting from both the spiked PhACs and the compounds naturally occurring in the secondary wastewater effluent were identified through UPLC-QTOF/MS/MS. Some of them, produced mainly from carbamazepine and trimethoprim, were still present at the end of the photolytic treatment, while they were completely or partially removed by the photocatalytic treatment.
This study evaluated whether some chemical and microbial contaminants in treated sewage effluents from two wastewater treatment plants (WWTP) reached the groundwater when they drained through a fractured karst vadose zone (WWTP-K) and a porous vadose zone (WWTP-P). Forty-five samples of sewage water (SW), treated water (TW), and monitoring well (MW), collected from WWTP-P (24) and WWTP-K (21), were analyzed for a range of microbiological and chemical properties. The E. coli and Salmonella counts were below the limits outlined in the Legislative Decree 152/06 in effluents from both types of WWTP. Enteric viruses were found in 37.5% and 12.5% of the SW and TW from WWTP-P, respectively. The percentages of Pepper mild mottle virus isolated were higher in TW (62.5% in WWTP-P, 85.7% in WWTP-K) than in SW and MW. The residual concentrations of contaminants of emerging concern (CEC) of each drug category were higher in the MW downstream of WWTP-K than of WWTP-P. Our results showed that the porous vadose zone was more effective at reducing the contaminant loads than the fractured karst one, especially the CEC, in the effluent. The legislation should include other parameters to minimize the risks from treated effluent that is discharged to soil.
We examined the temporal profiles of many organic micropollutants analysed in a sediment core sampled from a highly anthropized tributary of the Po River, the Lambro River. Analysed for extractable organic halogens (EOX), total petroleum hydrocarbons (C10-C40TPH), polycyclic aromatic hydrocarbons (PAHs), common legacy pollutants (DDTs, PCBs), halogenated flame retardants (PBDEs, DBDPE, TBBPA-bis, TCBPA, TBBPA, HBCDs), organotins (TBT, TPhT), antimicrobials (TCS, TCC), fragrances (AHTN, HHCB) and phthalates (DMP, DEP, DnBP, BBP, DEHP, DnOP), the dated sediment core revealed the historical record of 50 years of chemical contamination discharged into the Lambro and thereby the Po River. In this regard, the peak levels of PCBs and DDTs found in Lambro sediments were also identified in other sediment cores collected from the Po River prodelta in the Adriatic Sea, thus hundreds of kilometres downstream (Combi et al., 2020). The highest risk to aquatic organisms was associated with decades of high levels of C10-C40 TPH, PBDEs, PCBs, PAHs, DDTs, EOX, TCC, AHTN and DEHP, which in different periods of the contamination history, showed exceedances of guideline/threshold values. C10-C40 TPH and TCC, for example, were very high in the 1960s, whereas PCBs, DDTs, and PBDEs, peaked from the 1980s onward. The corresponding sums of PEC quotients ranged between 0.48 and 28.63, with a mean value (±SD) for the entire recording period of 10.62 ± 9.83. Environmental legislations and improved wastewater treatments were the main drivers of the recent downward trends observed for most of the chemicals investigated. Floods in turn resulted in macroscopic yet temporary improvements in the chemical quality of the tributary, conveying contaminated sediments into the Po River.
Endocrine disrupting compounds (EDCs) in the environment are considered a motif of concern, due to the widespread occurrence and potential adverse ecological and human health effects. The natural estrogen, 17β-estradiol (E2), is frequently detected in receiving water bodies after not being efficiently removed in conventional wastewater treatment plants (WWTPs), promoting a negative impact for both the aquatic ecosystem and human health. In this study, the biodegradation of E2 by Rhodococcus sp. ED55, a bacterial strain isolated from sediments of a discharge point of WWTP in Coloane, Macau, was investigated. Rhodococcus sp. ED55 was able to completely degrade 5 mg/L of E2 in 4 h in a synthetic medium. A similar degradation pattern was observed when the bacterial strain was used in wastewater collected from a WWTP, where a significant improvement in the degradation of the compound occurred. The detection and identification of 17 metabolites was achieved by means of UPLC/ESI/HRMS, which proposed a degradation pathway of E2. The acute test with luminescent marine bacterium Aliivibrio fischeri revealed the elimination of the toxicity of the treated effluent and the standardized yeast estrogenic (S-YES) assay with the recombinant strain of Saccharomyces cerevisiae revealed a decrease in the estrogenic activity of wastewater samples after biodegradation.
Syngas purification via wet-scrubbing processes generates a relevant amount of wastewater, which requires proper treatments before its disposal or reuse. Integrating chemical with cost-saving biological approaches represent a valuable alternative to traditional chemical-physical treatments. This study investigated the effectiveness of the BIO&CHEM treatment scheme for the treatment and reuse of wastewater collected from a wet-scrubber unit (chemical oxygen demand, COD = 2600 mg/L) containing several hazardous pollutants such as phenol (110 mg/L) and xylene (64 mg/L). The BIO&CHEM system included a sequencing batch biofilter granular reactor (SBBGR) and an ozonation unit that were operated at different hydraulic retention times (HRTs, from 5 to 1 day) and transferred ozone doses (TODs, 400, 280 and 250 mg/Linf), respectively. When a 4 d-HRT was selected, biologically treated wastewater was characterized by a COD of 140 mg/L and its toxicity on Daphnia magna was decreased from 100% to 5%. The integration between the biological SBBGR-based treatment (HRT = 1.5 d) and the ozonation (TOD = 280 mg/Linf) lowered effluent COD to 33 mg/L and erased toxicity on Daphnia magna. This operating condition resulted the most sustainable enabling multiple wastewater reuse and a significant reduction of plant size comparing with the biological treatment. Furthermore, the investigated aromatic and polyaromatic hydrocarbons (PAHs) and volatile organic compounds (VOCs; including benzene, toluene, xylene and phenol) were completely removed. The analysis of the reactor biomass, performed at the end of the experimental trial, excluded also their mere accumulation within the reactor due to absorption or adsorption on the sludge.