Correction to: European Journal of Clinical Nutrition (2015) 69, 309–313; doi: 10.1038/ejcn.2014.261; published online 14 January 2015 Since the publication of this article, the authors have noticed that several of the author names were published incorrectly. The correct author names are listed above.
PURPOSE:Cardiopulmonary bypass is still a major cause of lung injury and delay in pulmonary recovery after cardiac surgery. Although it has been shown that pulsatile flow induced by intra-aortic balloon pumping is beneficial for preserving lung function, it is not clear if the same beneficial effect can be accomplished with pulsatile flow generated in the extracorporeal circuit. Therefore, we investigated the effect of pulsatile flow, produced by a centrifugal pump, on lung function in elderly patients.METHODS:Serial measurements of lung biomarkers Clara cell 16 kD protein, surfactant protein D, and elastase were performed on blood samples from 37 elderly patients (≥75 years) who underwent elective aortic valve replacement surgery with CPB, either with pulsatile perfusion or continuous perfusion. Pulmonary function was assessed by postoperative ventilation time, the arterial blood oxygenation (PaO2/FiO2), the alveolar-arterial oxygen gradient (Aa-O2 gradient) and the pulmonary vascular resistance indexed by body surface area (PVRi).RESULTS:There was no difference in lung function between both groups, as assessed by the postoperative ventilation time, the PaO2/FiO2 ratio, and the Aa-O2 gradient. The PVRi, however, was significantly lower in the pulsatile perfusion group 15 mins after the administration of protamine (p<0.05). The plasma concentrations of the lung biomarkers increased during surgery and peaked at 1 h ICU, there were however no differences between groups.CONCLUSIONS:Pulsatile flow does not seem beneficial to postoperative lung function in elderly patients. Moreover, pulsatile flow does not affect lung function on a subclinical level as assessed by lung biomarkers.
Chronic kidney disease (CKD), especially in its end stage, is marked by extremely high cardiovascular rates of morbidity and mortality; hemodialysis patients have a five-fold shorter life expectancy than healthy subjects of the same age. In CKD the metabolic products that accumulate in the body are so-called uremic toxins. These include advanced glycation end-products (AGE). AGE levels are markedly increased in CKD patients not only because of impaired excretion but also because of increased production. AGE formation has initially been described as a non-enzymatic reaction between proteins and glucose in the so-called Maillard reaction, but they are also more rapidly formed during oxidative stress and subsequent formation of reactive carbonyl compounds like (methyl) glyoxal. AGE accumulate in tissue where they cross-link with proteins, e. g., collagen, inducing tissue stiffening of blood vessels and skin. They may also interact with receptor of AGE (RAGE) and other receptors, which lead to activation of intracellular transduction mechanisms resulting in cytokine release and further tissue damage in CKD. The accumulation of AGE in the skin can be measured non-invasively using autofluorescence. The skin autofluorescence is a strong marker of cardiovascular mortality in CKD. The focus of this review is on the role of tissue and plasma AGE, and of skin autofluorescence as a proxy of tissue AGE accumulation, in the increase in cardiovascular disease in end stage renal disease (ESRD). This review will also present the possibility of reducing the AGE accumulation in ESRD patients using the following five methods: 1) use of low AGE peritoneal dialysis solutions; 2) use of advanced hemodialysis techniques; 3) use of AGE reducing drugs; 4) optimizing the nutrition of hemodialysis patients; and 5) renal transplantation.
Abstract Chronic kidney disease (CKD), especially in its end stage, is marked by extremely high cardiovascular rates of morbidity and mortality; hemodialysis patients have a five-fold shorter life expectancy than healthy subjects of the same age. In CKD the metabolic products that accumulate in the body are so-called uremic toxins. These include advanced glycation end-products (AGE). AGE levels are markedly increased in CKD patients not only because of impaired excretion but also because of increased production. AGE formation has initially been described as a non-enzymatic reaction between proteins and glucose in the so-called Maillard reaction, but they are also more rapidly formed during oxidative stress and subsequent formation of reactive carbonyl compounds like (methyl)glyoxal. AGE accumulate in tissue where they cross-link with proteins, e.g., collagen, inducing tissue stiffening of blood vessels and skin. They may also interact with receptor of AGE (RAGE) and other receptors, which lead to activation of intracellular transduction mechanisms resulting in cytokine release and further tissue damage in CKD. The accumulation of AGE in the skin can be measured non-invasively using autofluorescence. The skin autofluorescence is a strong marker of cardiovascular mortality in CKD. The focus of this review is on the role of tissue and plasma AGE, and of skin autofluorescence as a proxy of tissue AGE accumulation, in the increase in cardiovascular disease in end stage renal disease (ESRD). This review will also present the possibility of reducing the AGE accumulation in ESRD patients using the following five methods: 1) use of low AGE peritoneal dialysis solutions; 2) use of advanced hemodialysis techniques; 3) use of AGE reducing drugs; 4) optimizing the nutrition of hemodialysis patients; and 5) renal transplantation.
Background: Despite continuous improvements in materials and perfusion techniques, cardiac surgery still causes lung injury and a delay of pulmonary recovery. Currently, there is no gold standard for quantifying cardiac surgery induced lung injury and dysfunction. Adding objective measures, such as plasma biomarkers, could be of great use here. In this study the utility of lung epithelium specific proteins as biomarkers for lung dysfunction was evaluated.Methods: Serial measurements of plasma concentrations of Clara cell 16 kD (CC16) protein, Surfactant protein D (SP-D), Elastase and Myeloperoxidase were performed on blood samples from 40 patients who underwent coronary artery bypass grafting with cardiopulmonary bypass (CABG, n = 20) or without cardiopulmonary bypass (OPCAB, n = 20).Results: The increase of SP-D and CC16 between pre-operative concentrations and concentrations at the end of cardiopulmonary bypass, correlated with the Aa-O-2 gradient at 1 hour on the ICU (R-s = 0.409, p = .016 and R-s = 0.343, p = .043, respectively). Furthermore, SP-D and CC16 were higher in CABG than in OPCAB at the end of surgery [8.96 vs. 4.91 ng/mL, p = .042 and 92 vs. 113%, p = .007, respectively]. After 24 h both biomarkers returned to their baseline values.Conclusions: Our results show that increases in plasma of SP-D and CC16 correlate with clinical lung injury after coronary artery bypass surgery. Therefore, lung epithelium specific proteins seem to be a useful biomarker for measuring lung injury in the setting of cardiac surgery.
Donations after circulatory death (DCD) lung grafts are an alternative to extend the donor pool in lung transplantation. This study investigates the use of an in situ lung perfusion system (ISLP) in the donor to evaluate category I–II lungs. Pigs were sacrificed by ventricular fibrillation. All animals underwent 20 min of cardiopulmonary resuscitation and 5 min hands‐off period after which heparin was administered. In group [WI‐1], this was followed by 1 h of warm ischemia (WI) and 2 h of topical cooling (TC). In group [WI‐2], 2 h of WI was followed by 1 h of TC. In group [WI‐0], there was a minimal period of WI and no TC. In all three groups, the lungs were then evaluated during 60 min with ISLP. [WI‐0] lungs showed a significantly higher compliance and Δ PO2/FiO2 compared with [WI‐1] and [WI‐2]. PaCO2 and lactate production were higher in [WI‐2] versus [WI‐0]. Wet/Dry weight ratio was significantly higher in [WI‐2] compared with [WI‐0] in two lung biopsy locations. A high W/D weight ratio was correlated with a lower compliance, higher lactate production, and a higher PaCO2. ISLP is an effective way to assess the quality of lungs from category I–II DCD donors.
Advanced glycation end-products (AGEs) are uremic toxins that accumulate progressively in hemodialysis (HD) patients. The aim of this study was to assess the 1-year increase in skin autofluorescence (ΔAF), a measure of AGEs accumulation and plasma markers, as predictors of mortality in HD patients. One hundred sixty-nine HD patients were enrolled in this study. Skin autofluorescence was measured twice, 1 year apart using an AGE Reader (DiagnOptics Technologies BV, Groningen, The Netherlands). Besides routine blood chemistry, additional plasma markers including superoxide dismutase, myeloperoxydase, intercellular adhesion molecule 1 (ICAM-1), C-reactive protein (hs-CRP), heart-type fatty acid binding protein (H-FABP), and von Willebrand factor were measured at baseline. The mortality of HD patients was followed for 36 months. Skin autofluorescence values of the HD patients at the two time points were significantly higher (P < 0.001) than those of healthy subjects of the same age. Mean 1-year ΔAF of HD patients was 0.16 ± 0.06, which was around seven- to ninefold higher than 1-year ΔAF in healthy subjects. Multivariate Cox regression showed that age, hypertension, 1-year ΔAF, hs-CRP, ICAM-1, and H-FABP were independent predictors of overall mortality. Hypertension, 1-year ΔAF, hs-CRP, and H-FABP were also independent predictors of cardiovascular mortality. One-year ΔAF and plasma H-FABP, used separately and in combination, are strong predictors of overall and cardiovascular mortality in HD patients.
Skin autofluorescence (AF) is related to the accumulation of advanced glycation end products (AGEs) and is one of the strongest prognostic markers of mortality in hemodialysis (HD) patients. The aim of this pilot study was to investigate whether changes in skin AF appear after a single HD session and if they might be related to changes in plasma AF. Skin and plasma AF were measured before and after HD in 35 patients on maintenance HD therapy (nine women and 26 men, median age 68 years, range 33-83). Median dialysis time was 4 h (range 3-5.5). Skin AF was measured noninvasively with an AGE Reader, and plasma AF was measured before and after HD at 460 nm after excitation at 370 nm. The HD patients had on average a 65% higher skin AF value than age-matched healthy persons (P < 0.001). Plasma AF was reduced by 14% (P < 0.001), whereas skin AF was not changed after a single HD treatment. No significant influence of the reduced plasma AF on skin AF levels was found. This suggests that the measurement of skin AF can be performed during the whole dialysis period and is not directly influenced by the changes in plasma AF during HD.
Current clinical lung preservation techniques have not eliminated ischaemia-reperfusion (I/R) injury, despite many improvements. The optimal combination of flush and storage temperatures remain unclear in lung preservation. This is the first study to investigate a range of temperatures with 24-h inflated storage using consistent state-of-the-art preservation techniques. A rat lung transplant model was used to investigate the optimal combination of flush and storage temperatures. In six groups, rat lungs were flushed at 4 °C, 10 °C or room temperature (F(4) /F(10) /F(Rt)) with Perfadex and stored inflated for 24 h in Perfadex on melting ice or at 10 °C (S(ice) /S(10)). Left donor lungs were transplanted for analysis. During 2-h reperfusion, the lung graft function was measured (blood gases, maximum ventilation pressure and static compliance) and lung graft injury was also assessed (W/D ratio, total lung protein, Tryptase, Myeloperoxidase). Right donor lungs were assessed for W/D ratio only after flush and storage. For baseline measurements, left lungs without intervention were used. The combination of F(Rt) -S(ice) showed a significantly higher pO(2), lower P(max), low W/D ratios and total protein levels of left lungs after reperfusion when compared with F(4) -S(ice) and baseline. Storage at 10 °C did not improve preservation. We conclude that F(Rt) -S(ice) creates the best lung graft preservation.
TransfusionVolume 52, Issue 10 p. 2272-2273 Does modern combat still need fresh whole blood transfusions? Sandra Henkelman PhD, Sandra Henkelman PhD e-mail: Sandra.Henkelman@gmail.comSearch for more papers by this authorGerhard Rakhorst PhD, Gerhard Rakhorst PhD Department of Surgery, University Medical Center Groningen, University of Groningen, Groningen, The NetherlandsSearch for more papers by this author Sandra Henkelman PhD, Sandra Henkelman PhD e-mail: Sandra.Henkelman@gmail.comSearch for more papers by this authorGerhard Rakhorst PhD, Gerhard Rakhorst PhD Department of Surgery, University Medical Center Groningen, University of Groningen, Groningen, The NetherlandsSearch for more papers by this author First published: 30 October 2012 https://doi.org/10.1111/j.1537-2995.2012.03749.xCitations: 1Read the full textAboutPDF ToolsRequest permissionExport citationAdd to favoritesTrack citation ShareShare Give accessShare full text accessShare full-text accessPlease review our Terms and Conditions of Use and check box below to share full-text version of article.I have read and accept the Wiley Online Library Terms and Conditions of UseShareable LinkUse the link below to share a full-text version of this article with your friends and colleagues. Learn more.Copy URL Share a linkShare onFacebookTwitterLinked InRedditWechat No abstract is available for this article.Citing Literature Volume52, Issue10October 2012Pages 2272-2273 RelatedInformation
Aggregation of human red blood cells (RBC) remains of biological and clinical interest. Replacement of plasma proteins by polymers to induce RBC aggregation may help to unravel the fundamentals of the aggregation process. Two theories exist to explain RBC aggregation mechanisms: a depletion and a bridging theory. RBC aggregation induced by hydroxyethyl starch (HES) increases with polymer size, which suggests that aggregation is induced via the bridging theory. In this study, the electrophoretic mobility (EPM) was measured to investigate RBC aggregation induced by 200 kDa HES polymers. Also, we evaluated if these polymers were useful for demonstrating aggregation differences between RBCs from healthy and type-1 diabetes mellitus (T1DM) subjects. Our results demonstrate that EPM values of RBCs in 200 kDa HES solutions were less negative than could be predicted by the viscosity of the suspension, supporting the bridging theory. Furthermore, aggregation analysis using the LORCA demonstrated that 200 kDa HES solution enhanced RBC aggregation of healthy and diabetic subjects similarly as standard 500 kDa dextran solutions. In conclusion: our data supports the bridging mechanism underlying 200 kDa HES induced RBC aggregation. In addition, both polymers are useful for demonstrating cellular induced aggregation differences between RBCs from healthy and T1DM subjects.
Although the centrifugal pump has been widely used as a nonpulsatile pump for cardiopulmonary bypass (CPB), little is known about its performance as a pulsatile pump for CPB, especially on its efficacy in producing hemodynamic energy and its clinical effectiveness. We performed a study to evaluate whether the Rotaflow centrifugal pump produces effective pulsatile flow during CPB and whether the pulsatile flow in this setting is clinically effective in adult patients undergoing cardiac surgery. Thirty-two patients undergoing CPB for elective coronary artery bypass grafting were randomly allocated to a pulsatile perfusion group (n = 16) or a nonpulsatile perfusion group (n = 16). All patients were perfused with the Rotaflow centrifugal pump. In the pulsatile group, the centrifugal pump was adjusted to the pulsatile mode (60 cycles/min) during aortic cross-clamping, whereas in the nonpulsatile group, the pump was kept in its nonpulsatile mode during the same period of time. Compared with the nonpulsatile group, the pulsatile group had a higher pulse pressure (P < 0.01) and a fraction higher energy equivalent pressure (EEP, P = 0.058). The net gain of pulsatile flow, represented by the surplus hemodynamic energy (SHE), was found much higher in the CPB circuit than in patients (P < 0.01). Clinically, there was no difference between the pulsatile and nonpulsatile groups with regard to postoperative acute kidney injury, endothelial activation, or inflammatory response. Postoperative organ function and the duration of hospital stay were similar in the two patient groups. In conclusion, pulsatile CPB with the Rotaflow centrifugal pump is associated with a small gain of EEP and SHE, which does not seem to be clinically effective in adult cardiac surgical patients.
K1 (EI0154) AGES IN HEMODIALYSIS: TISSUEAND PLASMAAUTOFLUORESCENCE R. Graaff1, S. Arsov1, L. Trajceska4, P. Dzekova4, G.E. Engels1, M. Koetsier1, W. van Oeveren1, L Lundberg5, S. Assa2, C.F.M. Franssen2, A.J. Smit3, G. Rakhorst1, A. Sikole2, B. Stegmayr5 1Dept. of Biomedical Engineering, 2Internal Medicine, Div. Nephrology and 3Div. Vascular Medicine, University Medical Center Groningen, Groningen, The Netherlands; 4Department of Nephrology, University Clinic of Nephrology, Skopje, R. Macedonia; 5Department of Internal Medicine, University Hospital, Umea, Sweden