Antibody combination therapies have become viable therapeutic treatment options for certain severe diseases such as cancer. The co-formulation production approach is intrinsically associated with more complex drug product variant profiles and creates more challenges for analytical control of drug product quality. In addition to various individual quality attributes, those arising from the interactions between the antibodies also potentially emerge through co-formulation. In this study, we describe the development of a widely applicable multi-dimensional liquid chromatography coupled to tandem mass spectrometry method for antibody homo- versus hetero-aggregate characterization. The co-formulation of trastuzumab and pertuzumab was used, a challenging model system, comprising two monoclonal antibodies with very similar physicochemical properties. The data presented demonstrate the high stability of the co-formulation, where only minor aggregate formation is observed upon product storage and accelerated temperature or light-stress conditions. The results also show that the homo- and hetero-aggregates, formed in low and comparable proportions, are only marginally impacted by the formulation and product storage conditions. No preferential formation of hetero-aggregates, in comparison to the already existing pertuzumab and trastuzumab homo-aggregates, was observed.
Poloxamer 188 (P188) is formulated in proteinaceous therapeutics as an alternative surfactant to polysorbate because of its good chemical stability and surfactant properties, which enable interfacial protection, preventing visible and sub-visible particle formation. However, due to the nature of polymer heterogeneity and limited analytical approaches to resolve the superimposed components of P188, the impact of its quality variance on protein stability is still not well understood. In this study, we developed an analytical method to evaluate the components of P188 as a function of the length of polypropylene oxide (PPO), by maintaining polyethylene oxide (PEO) at the critical point of adsorption (CPA) to eliminate its chromatographic interference. The effectiveness of the separation was confirmed by nuclear magnetic resonance (NMR) spectroscopy and mass spectroscopy (MS) of the individual fractions corresponding to each peak. Additionally, a design of experiments (DoE) and method qualification were carried out to identify and optimize the key operation parameters, including column temperature and evaporative light scattering detector (ELSD) settings that need to be strictly controlled for reliable analytical results. In conclusion, this method is sensitive and reliable to compare the quality variance of commercial P188 and is suitable for routine quality control purposes. The application of this method could help in further understanding the Critical Material Attributes (CMA) that may affect the quality attributes of proteins in formulations.