Precise genome editing via homology-directed repair (HDR) after double-stranded DNA (dsDNA) cleavage facilitates functional genomic research and holds promise for gene therapy. However, HDR efficiency remains low in some cell types, including some of great research and clinical interest, such as human induced pluripotent stem cells (iPSCs).
The objective of this study was to develop a novel microcomposite implant to be used in the treatment of osteomyelitis following total joint arthroplasty, with the dual purpose of releasing high local concentrations of antibiotic to eradicate the infection while providing adequate mechanical strength to maintain the dynamic or static spacer. Vancomycin‐loaded microcomposite implants were fabricated by incorporating drug‐loaded microparticles comprised of mesoporous silica into commonly employed polymethylmethacrylate (PMMA) bone cement, to yield a final drug loading of 10% w/w. In vitro release kinetics at 37°C were monitored by reverse‐phase high‐performance liquid chromatography, and compared to the release kinetics of current therapy implants consisting of drug alone incorporated at 10% w/w directly into PMMA bone cement. Results demonstrated a sevenfold improvement in the elution profile of microcomposite systems over current therapy implants. In vivo delivery of vancomycin to bone from microcomposite implants (70% of payload) was significantly higher than that from current therapy implants (approx. 22% of payload) and maintained significantly higher bone concentrations for up to 2 weeks duration. The elastic modulus showed no statistical difference between microcomposite implants and current standard therapy implants before drug elution, and maintenance of acceptable strength of microcomposite implants postdrug elution. These results demonstrate that we have developed a novel microcomposite spacer that will release continuously high antibiotic concentrations over a prolonged period of time, offering the possibility to eliminate infection and avoid the emergence of new resistant bacterial strains, while maintaining the requisite mechanical properties for proper space maintenance and joint fixation.
We have developed an improved episomal vector system for efficient generation of integration-free induced pluripotent stem cells (iPSCs) from peripheral blood mononuclear cells. More recently, we reported that the use of an optimized CRISPR-Cas9 system together with a double-cut donor increases homology-directed repair-mediated precise gene knockin efficiency by 5- to 10-fold. Here, we report the integration of blood cell reprogramming and genome editing in a single step. We found that expression of Cas9 and KLF4 using a single vector significantly increases genome editing efficiency, and addition of SV40LT further enhances knockin efficiency. After these optimizations, genome editing efficiency of up to 40% in the bulk iPSC population can be achieved without any selection. Most of the edited cells show characteristics of iPSCs and genome integrity. Our improved approach, which integrates reprogramming and genome editing, should expedite both basic research and clinical applications of precision and regenerative medicine.
Genome editing of human induced pluripotent stem cells (iPSCs) is instrumental for functional genomics, disease modeling, and regenerative medicine. However, low editing efficiency has hampered the applications of CRISPR-Cas9 technology in creating knockin (KI) or knockout (KO) iPSC lines, which is largely due to massive cell death after electroporation with editing plasmids. Here, we report that the transient delivery of BCL-XL increases iPSC survival by similar to 10-fold after plasmid transfection, leading to a 20- to 100-fold increase in homology-directed repair (HDR) KI efficiency and a 5-fold increase in non-homologous end joining (NHEJ) KO efficiency. Treatment with a BCL inhibitor ABT-263 further improves HDR efficiency by 70% and KO efficiency by 40%. The increased genome editing efficiency is attributed to higher expressions of Cas9 and sgRNA in surviving cells after electroporation. HDR or NHEJ efficiency reaches 95% with dual editing followed by selection of cells with HDR insertion of a selective gene. Moreover, KO efficiency of 100% can be achieved in a bulk population of cells with biallelic HDR KO followed by double selection, abrogating the necessity for single cell cloning. Taken together, these simple yet highly efficient editing strategies provide useful tools for applications ranging from manipulating human iPSC genomes to creating gene-modified animal models.
This article reports the degradation and biological properties of as-drawn Mg-4Zn-1Sr (designated as ZSr41) and pure Mg (P-Mg) wires as bioresorbable intramedullary pins for bone repair. Specifically, their cytocompatibility with bone marrow derived mesenchymal stem cells (BMSCs) and degradation in vitro, and their biological effects on peri-implant tissues and in vivo degradation in rat tibiae were studied. The as-drawn ZSr41 pins showed a significantly faster degradation than P-Mg in vitro and in vivo. The in vivo average daily degradation rates of both ZSr41 and P-Mg intramedullary pins were significantly greater than their respective in vitro degradation rates, likely because the intramedullary site of implantation is highly vascularized for removal of degradation products. Importantly, the concentrations of Mg2+, Zn2+, and Sr2+ ions in the BMSC culture in vitro and their concentrations in rat blood in vivo were all lower than their respective therapeutic dosages, i.e., in a safe range. Despite of rapid degradation with a complete resorption time of 8 weeks in vivo, the ZSr41 intramedullary pins showed a significant net bone growth because of stimulatory effects of the metallic ions released. However, proportionally released OH- ions and hydrogen gas caused adverse effects on bone marrow cells and resulted in cavities in surrounding bone. Thus, properly engineering the degradation properties of Mg-based implants is critical for harvesting the bioactivities of beneficial metallic ions, while controlling adverse reactions associated with the release of OH- ions and hydrogen gas. It is necessary to further optimize the alloy processing conditions and/or modify the surfaces, for example, applying coatings onto the surface, to reduce the degradation rate of ZSr41 wires for skeletal implant applications.
Induced Pluripotent Stem Cells (iPSCs) hold great promise for disease modeling and regenerative therapies. We previously reported the use of Episomal Vectors (EV) to generate integration-free iPSCs from peripheral blood mononuclear cells (PB MNCs). The episomal vectors used are DNA plasmids incorporated with oriP and EBNA1 elements from the Epstein-Barr (EB) virus, which allow for replication and long-term retainment of plasmids in mammalian cells, respectively. With further optimization, thousands of iPSC colonies can be obtained from 1 mL of peripheral blood. Two critical factors for achieving high reprogramming efficiencies are: 1) the use of a 2A "self-cleavage" peptide to link OCT4 and SOX2, thus achieving equimolar expression of the two factors; 2) the use of two vectors to express MYC and KLF4 individually. Here we describe a step-by-step protocol for generating integration-free iPSCs from adult peripheral blood samples. The generated iPSCs are integration-free as residual episomal plasmids are undetectable after five passages. Although the reprogramming efficiency is comparable to that of Sendai Virus (SV) vectors, EV plasmids are considerably more economical than the commercially available SV vectors. This affordable EV reprogramming system holds potential for clinical applications in regenerative medicine and provides an approach for the direct reprogramming of PB MNCs to integration-free mesenchymal stem cells, neural stem cells, etc.
The use of cobalt chrome (CoCr) implants in spinal surgery has become increasingly popular. However, there have been no studies specifically comparing biofilm formation on CoCr with that of titanium-alloy spinal implants. The objective of this study was to compare the difference in propensity for biofilm formation between these two materials, as it specifically relates to spinal rods. Staphylococcus aureus subsp. Aureus (ATCC 6538) were incubated with two different types of spinal rods composed of either CoCr or titanium-alloy. The spinal rods were then subject to a trypsin wash to allow for isolation of the colonized organism and associated biofilms. The associated optical density values (OD) from the bacterial isolates were obtained and the bacterial solutions were plated on brain-heart infusion agar plates and the resultant colony-forming units (CFU) were counted. The OD values for the titanium-alloy rods were 1.105±0.096nm (mean±SD) and 1.040±0.026nm at 48hours and 96hours, respectively. In contrast, the OD values for the CoCr rods were 1.332±0.161nm and 1.115±0.207nm at 48 and 96hours, respectively (p<0.05). The CFU values were 1481±417/100mm(2) and 745±159/100mm(2) at 48 and 96hours, respectively for the titanium-alloy group. These values were significantly lower than the CFU values obtained from the CoCr group which were 2721±605/100mm(2) and 928±88/100mm(2) (p<0.001) at both 48 and 96hours respectively. Our findings, evaluating both the OD and CFU values, indicate that implants composed of CoCr had a higher proclivity towards biofilm formation compared to titanium-alloy implants.