The almost-two-centuries history of spectrochemical analysis has generated a body of literature so vast that it has become nearly intractable for experts, much less for those wishing to enter the field. Authoritative, focused reviews help to address this problem but become so granular that the overall directions of the field are lost. This broader perspective can be provided partially by general overviews but then the thinking, experimental details, theoretical underpinnings, and instrumental innovations of the original work must be sacrificed. In the present compilation, this dilemma is overcome by assembling the most impactful publications in the area of analytical atomic spectrometry. Each entry was proposed by at least one current expert in the field and supported by a narrative that justifies its inclusion. The entries were then assembled into a coherent sequence and returned to contributors for a round-robin review. A total of 48 scientists participated in this endeavor, contributing a combined list of 1055 individual articles spanning 17 sub-disciplines of spectrochemical analysis into what the current community views as "key" publications. Of these cited articles, 60 received nominations from four or more scientists, establishing them as the most indispensable reading materials. The outcome of this collaborative effort is intended to serve as a valuable resource not only for current practitioners in atomic spectroscopy but also for present and future students who represent coming generations of analytical atomic spectroscopists.
The low-temperature plasma (LTP) probe is a common plasma-based source used for ambient desorption-ionization mass spectrometry (MS). While the LTP probe has been characterized in detail with MS, relatively few studies have used optical spectroscopy. In this paper, two-dimensional (2D) imaging at selected wavelengths is used to visualize important species in the LTP plasma jet. First, 2D steady-state images of the LTP plume for N2+ (391.2 nm), He I (706.5 nm), and N2 (337.1 nm) emissions were recorded under selected plasma conditions. Second, time-resolved 2D emission maps of radiative species in the LTP plasma jet were recorded through the use of a 200 ns detection gate and varying gate delays with respect to the LTP trigger pulse. Emission from He I, N2+, and N2 in the plasma jet region was found to show a transient behavior (often referred to as plasma bullets) lasting only a few microseconds. The N2+ and He I maps were highly correlated in spatial and temporal structure. Further, emission from N2 showed two maxima in time, one before and one after the maximum emission for N2+ and He I, due to an initial electronic excitation wave and ion-electron recombination, respectively. Third, the interaction of the LTP probe with a sample substrate and an electrically grounded metallic needle was studied. Emission from a fluorophore on the sample substrate showed an initial photon-induced excitation from plasma-generated photons followed by electronic excitation by other plasma species. The presence of a grounded needle near the plasma jet significantly extended the plasma jet lifetime and also generated a long-lived corona discharge on the needle. The effect of LTP operating parameters on emission spectra was correlated with mass-spectral results including reagent-ion signals. Lastly, five movies provide a side-by-side comparison of the temporal behavior of emitting species and insights into the interactions of the emission clouds with a sample surface as well as an external needle. Temporally and spatially resolved imaging provided insights into important processes in the LTP plasma jet, which will help improve analyte ion sampling in LTP-MS. Graphical AbstractThis is a visual representation of the abstract.
Guest Editors Gary M. Hieftje and Joanna Szpunar introduce this themed collection in honor of Ramon M. Barnes.
The mass of the hydrogen isotope in micrometer-sized aqueous droplets introduced into an ICP has been found to affect the degree of resulting plasma perturbation. Studied plasma perturbations include local plasma cooling, plasma shrinkage due to thermal pinching, and changes in plasma impedance. The local cooling effect caused by a vaporizing aerosol droplet was found to be similar between H2O and D2O. This finding is likely a result of the similar heat capacities and vaporization rates of H2O and D2O droplets and of the comparable thermal conductivities and dissociation kinetics of H2O and D2O vapor. In contrast, a clear isotope effect was observed for plasma shrinkage and impedance change, with H2O causing a considerably stronger effect. Plasma shrinkage, gauged by the reduction in Ar emission at the edge of the plasma, was detected at all observation heights within the load-coil region, with D2O droplets causing as much as 30% less of an effect than H2O. Likewise, D2O droplets induce significantly less change in plasma impedance than H2O droplets. Depending on experimental conditions and the probing method, changes in plasma impedance caused by monodisperse D2O droplets were only 52%-80% that of H2O. The lower influence on plasma shrinkage and impedance change for D2O droplets is believed to be related to the much lower thermal conductivity of atomic deuterium, around 70% that of atomic hydrogen (protium). The time required for the plasma impedance to return to its original steady-state value was comparatively long (similar to 10 ms) and similar for H2O and D2O droplets.
Matrix effects caused by Na and Al in the nitrogen Microwave-sustained, Inductively Coupled, Atmospheric pressure Plasma (MICAP) were investigated. Easily ionizable elements, such as Na, can suppress or enhance the analyte signal; Al is shown here to produce a similar effect. The influence of these matrices was examined for 18 emission lines of 8 analyte atoms and ions having a wide range of excitation and ionization energies. The plasma operating conditions were fixed during all experiments at a total nitrogen flow of 19.4 L min(-1) and a microwave power of 1.5 kW. An Fe solution was used to determine the excitation temperature of the plasma by the Boltzmann plot method at selected matrix concentrations. In addition, vertical emission profiles of the plasma were measured. The matrix effect becomes worse at higher concentrations of an easily ionizable element. The effect is caused not only by a shift in ionization equilibrium but also by a possible change in plasma ionization temperature. Correction methods to reduce the matrix effects were tested and are discussed.
Journal of Physics D: Applied Physics published the first Plasma Roadmap in 2012 consisting of the individual perspectives of 16 leading experts in the various sub-fields of low temperature plasma science and technology. The 2017 Plasma Roadmap is the first update of a planned series of periodic updates of the Plasma Roadmap. The continuously growing interdisciplinary nature of the low temperature plasma field and its equally broad range of applications are making it increasingly difficult to identify major challenges that encompass all of the many sub-fields and applications. This intellectual diversity is ultimately a strength of the field. The current state of the art for the 19 sub-fields addressed in this roadmap demonstrates the enviable track record of the low temperature plasma field in the development of plasmas as an enabling technology for a vast range of technologies that underpin our modern society. At the same time, the many important scientific and technological challenges shared in this roadmap show that the path forward is not only scientifically rich but has the potential to make wide and far reaching contributions to many societal challenges.
A new direct-current microplasma-based flowing atmospheric pressure afterglow (FAPA) source was developed for use in ambient desorption-ionization mass spectrometry. The annular-shaped microplasma is formed in helium between two concentric stainless-steel capillaries that are separated by an alumina tube. Current-voltage characterization of the source shows that this version of the FAPA operates in the normal glow-discharge regime. A glass surface placed in the path of the helium afterglow reaches temperatures of up to approximately 400 °C; the temperature varies with distance from the source and helium flow rate through the source. Solid, liquid, and vapor samples were examined by means of a time-of-flight mass spectrometer. Results suggest that ionization occurs mainly through protonation, with only a small amount of fragmentation and adduct formation. The mass range of the source was shown to extend up to at least m/z 2722 for singly charged species. Limits of detection for several small organic molecules were in the sub-picomole range. Examination of competitive ionization revealed that signal suppression occurs only at high (mM) concentrations of competing substances.
The flowing atmospheric-pressure afterglow (FAPA) source was used for the mass-spectrometric analysis of vapor samples introduced between the source and mass spectrometer inlet. Through interrupted operation of the plasma-supporting helium flow, helium consumption is greatly reduced and dynamic gas behavior occurs that was characterized by schlieren imaging. Moreover, mass spectra acquired immediately after the onset of helium flow exhibit a signal spike before declining and ultimately reaching a steady level. This initial signal appears to be due to greater interaction of sample vapor with the afterglow of the source when helium flow resumes. In part, the initial spike in signal can be attributed to a pooling of analyte vapor in the absence of helium flow from the source. Time-resolved schlieren imaging of the helium flow during on and off cycles provided insight into gas-flow patterns between the FAPA source and the MS inlet that were correlated with mass-spectral data. Graphical Abstract ᅟ.
Gary Hieftje and Maria Montes-Bayon emphasize Joe’s impact on the community, as reflected in a collection of articles published in JAAS and Metallomics.
A zoom–time-of-flight mass spectrometer has been coupled to an inductively coupled plasma (ICP) ionization source. Zoom–time-of-flight mass spectrometry (zoom-TOFMS) combines two complementary types of velocity-based mass separation. Specifically, zoom-TOFMS alternates between conventional, constant-energy acceleration (CEA) TOFMS and energy-focused, constant-momentum acceleration (CMA) (zoom) TOFMS. The CMA mode provides a mass-resolution enhancement of 1.5-1.7× over CEA-TOFMS in the current, 35-cm ICP-zoom-TOFMS instrument geometry. The maximum resolving power (full-width at half-maximum) for the ICP-zoom-TOFMS instrument is 1200 for CEA-TOFMS and 1900 for CMA-TOFMS. The CMA mode yields detection limits of between 0.02 and 0.8 ppt, depending upon the repetition rate and integration time—compared with single ppt detection limits for CEA-TOFMS. Isotope-ratio precision is shot-noise limited at approximately 0.2% relative-standard deviation (RSD) for both CEA- and CMA-TOFMS at a 10 kHz repetition rate and an integration time of 3–5 min. When the repetition rate is increased to 43.5 kHz for CMA, the shot-noise limited, zoom-mode isotope-ratio precision is improved to 0.09% RSD for the same integration time.
Together with the former Chairs, I have the pleasure to introduce the first 2016 issue of JAAS to you. All of our past/present Chairs have contributed to the content of this themed issue to commemorate that in 2015, JAAS celebrated its 30th anniversary! To introduce the issue a number of our Chairs have written a few words. We hope that you enjoy their recollections and the papers that have been included in this themed issue.
Our research group earlier used dispersion that occurs during flow injection to detect and reduce matrix interference in inductively coupled plasma–time-of-flight mass spectrometry (ICP-TOFMS). In the absence of a matrix interference, the ratio of signals from any two sample constituents should remain constant, independent of the dilution, over the course of a flow-injection transient. However, when an interferent is present, the signal ratio from different analytes will change with dilution, owing to the difference in severity of the interference on specific analytes. As a result, matrix interference can be recognized (flagged) by monitoring the signal ratios of two analytes over the course of a flow-injection transient; a ratio that changes over time indicates the presence of an interferent. The drawback of this earlier method was that dispersion, and therefore dilution, was somewhat element-specific, causing the ratios to wander even when no interference existed. Here, a gradient HPLC pump is used to overcome this drawback by creating a longer, better-controlled dilution. Under these conditions, variation in dispersion between elements is negligible and difficulties associated with it are reduced or eliminated. Further, when an interference exists, the optimal dilution factor to reduce the interference to an acceptable level can be found from the gradient-dilution curve as the point where the signal ratio between two elements becomes constant.
A novel inductively coupled plasma (ICP), termed the microwave-sustained, inductively coupled, atmospheric-pressure plasma (MICAP), has been developed that operates at microwave frequency (2.45 GHz).