Experimental binding free energies of 27 adamantyl amines against the influenza M2(22-46) WT tetramer, in its closed form at pH 8, were measured by ITC in DPC micelles. The measured Kd's range is -44 while the antiviral potencies (IC50) range is -750 with a good correlation between binding free energies computed with Kd and IC50 values (r = 0.76). We explored with MD simulations (ff19sb, CHARMM36m) the binding profile of complexes with strong, moderate and weak binders embedded in DMPC, DPPC, POPC or a viral mimetic membrane and using different experimental starting structures of M2. To predict accurately differences in binding free energy in response to subtle changes in the structure of the ligands, we performed 18 alchemical perturbative single topology FEP/MD NPT simulations (OPLS2005) using the BAR estimator (Desmond software) and 20 dual topology calculations TI/MD NVT simulations (ff19sb) using the MBAR estimator (Amber software) for adamantyl amines in complex with M2(22-46) WT in DMPC, DPPC, POPC. We observed that both methods with all lipids show a very good correlation between the experimental and calculated relative binding free energies (r = 0.77-0.87, mue = 0.36-0.92 kcal mol-1) with the highest performance achieved with TI/MBAR and lowest performance with FEP/BAR in DMPC bilayers. When antiviral potencies are used instead of the Kd values for computing the experimental binding free energies we obtained also good performance with both FEP/BAR (r = 0.83, mue = 0.75 kcal mol-1) and TI/MBAR (r = 0.69, mue = 0.77 kcal mol-1).
AbstractMehrdimensionale Trenntechniken sowie Kopplungstechniken verbessern weiter die Auflösung in der Analytik. In der Elementanalytik beeindrucken neue Entwicklungen der Massenspektrometrie mit induktiv gekoppeltem Plasma, in der Archäometrie zerstörungsfreie In‐situ‐Analysen. Der 3‐D‐Druck treibt die elektroanalytische Forschung voran, und die Prozessanalytik setzt auf Lab‐on‐a‐Chip und vermeldet Neues bei der Raman‐Spektroskopie mit Flüssigkernlichtleitern.
A new method to transfer the standard addition procedure for concentration determination to immunoassays with non-linear calibration curves was developed. The new method was successfully applied to simulated data and benchmarked against a state-of-the-art algorithm, showing a significantly improved performance with improvement factors between 2 and 192. The logit function was used to transform the immunoassay signal response of test samples spiked with known analyte concentrations. The relationship between logit(signal) and log-transformed estimated total analyte concentration is linear if the estimated total analyte concentration is correct. Finally, the new method was validated experimentally using different assays in varying, relevant complex matrices, such as serum, saliva, and milk. Different concentrations of testosterone and amitriptyline between 0.05 and 3.0 µg L−1 were quantified using a binding inhibition assay in combination with reflectometric interference spectroscopy (RIfS) as the transduction principle. The sample concentration was calculated using a numerical method. Samples could be quantified with recoveries between 70 and 118%. The standard addition method accounts for individual matrix interference on the immunoassay by spiking the test sample itself. Although the experiments were carried out using RIfS, the method can be applied to any immunoassay that meets the analytical requirements.
Antibody gold nanoparticle conjugates as recognition elements are essential for the overall performance of lateral flow assays. When immobilizing antibodies on gold nanoparticles, the challenge is to prevent aggregation and to ensure that the antibodies are correctly oriented so that they remain functional and their paratopes remain accessible. There are many methods available, and it is difficult to decide which one to use. To help selecting the most appropriate conjugate production method, different synthetic routes of binding antibodies to gold nanoparticles are systematically investigated for the purpose of a quantitative lateral flow test for small molecules. The direct comparison of different conjugate syntheses shows how to select a suitable conjugate for a lateral flow assay. The syntheses examined are direct adsorption of antibody, direct adsorption of reduced antibody, covalent binding to polyethylene glycol linker, and binding via biotin-streptavidin interaction. The conjugates are characterized using UV-Vis spectroscopy and dynamic light scattering to determine their stability. Their performance on structured lateral flow test strips is examined using calibrations for different amitriptyline concentrations. It was shown that the best conjugate for quantification of amitriptyline was realized by direct adsorption of an UV-light irradiated antibody to gold nanoparticles. The methods employed can serve as a guide for selecting the most appropriate conjugate for an application and enhance the performance of lateral flow assays.
Label-free biosensing has developed from niche application to state of the art biosensing technique throughout the past decades. The reason for the raise of acceptance for this technology is the fact, that it generates valuable kinetic data (on-and off-rates), does not require complicated sample-pre-treatment, and can be used in direct test formats. As the acceptance increased, label-free advanced and many different approaches with the same underlying principles have evolved. This review will take a brief look at the history, and explore the reflectometry family tree, which includes ellipsometry as the main ancestor, Reflectometric Interference Spectroscopy (RIfS), Biolayer Interferometry (BLI), Total Reflectometric Interference Spectroscopy (TRIS), Spectral Reflectance Imaging Biosensor (SRIB or also IRIS), 1 & x28e; Reflectometry, Arrayed Imaging Reflectometry (AIR), and Oblique-Incidence Reflectivity Difference microscopy (OI-RD) and highlight extraordinary examples of recent developments and their impact in biomolecular interaction analysis.
The present paper describes a compact point of care (POC) optical device for therapeutic drug monitoring (TDM). The core of the device is a disposable plastic chip where an immunoassay for the determination of immunosuppressants takes place. The chip is designed in order to have ten parallel microchannels allowing the simultaneous detection of more than one analyte with replicate measurements. The device is equipped with a microfluidic system, which provides sample mixing with the necessary chemicals and pumping samples, reagents and buffers into the measurement chip, and with integrated thin film amorphous silicon photodiodes for the fluorescence detection. Submicrometric fluorescent magnetic particles are used as support in the immunoassay in order to improve the efficiency of the assay. In particular, the magnetic feature is used to concentrate the antibody onto the sensing layer leading to a much faster implementation of the assay, while the fluorescent feature is used to increase the optical signal leading to a larger optical dynamic change and consequently a better sensitivity and a lower limit of detection. The design and development of the whole integrated optical device are here illustrated. In addition, detection of mycophenolic acid and cyclosporine A in spiked solutions and in microdialysate samples from patient blood with the implemented device are reported.
In order to perform good kinetic experiments, not only the experimental conditions have to be optimized, but the evaluation procedure as well. The focus of this work is the in-depth comparison of different approaches and algorithms to determine kinetic rate constants for biomolecular interaction analysis (BIA). The different algorithms are applied not only to flawless simulated data, but also to real-world measurements. We compare five mathematical approaches for the evaluation of binding curves following pseudo-first-order kinetics with different noise levels. In addition, reflectometric interference spectroscopy (RIfS) measurements of two antibodies are evaluated to determine their binding kinetics. The advantages and disadvantages of the individual approach will be investigated and discussed in detail. In summary, we will raise awareness on how to evaluate and judge results from BIA by using different approaches rather than having to rely on "black box" closed (commercial) software packages.
Fibronectin coating increases implant biocompatibility by enhancing surface endothelialization via integrin-mediated binding. Surface properties determine the fibronectin orientation and conformation, dictating which ligands are presented, and therefore altering the bioactivity of an implant surface. In this study, polyurethane was treated with oxygen plasma, which allowed for a simultaneous modification of the surface chemistry and topography to modulate fibronectin adsorption. By varying the parameters of the treatment, human plasma fibronectin adsorbed on the surfaces in different conformations, orientations, and binding affinities, which was investigated by atomic force microscopy, fluorescence microscopy, monoclonal and polyclonal antibody staining and reflectometric interference spectroscopy. Apart from the most hydrophilic rough surfaces, the adsorbed fibronectin showed a lower binding affinity and less conformational change on the more hydrophilic surfaces. A large amount of exposed fibronectin-cell binding was detected on the rough treated and the smooth untreated surfaces. Primary isolated human umbilical vein and human microvascular endothelial cells showed a significantly higher cell adherence on the absorbed fibronectin with a low binding affinity and low conformational changes. Significant differences in the formation of mature focal adhesions and the reorganization of F-actin were identified on the rough treated and the smooth untreated surfaces. Our data suggest that oxygen plasma treatment is a reliable technique for the modulation of fibronectin adsorption in order to adjust fibronectin bioactivity and impact cell responses to implant surfaces.
The demand of rapid and robust diagnostic tools in clinical and non-clinical environments has boosted the use of Point of Care Devices (POC) for measurement and control of a wide spectrum of health parameters and related therapeutic decisions. We have developed a paper-based POC device to be used for amitriptyline (AMT) measurement in serum. We designed a nitrocellulose test strip, structured with channels by femtosecond laser ablation which conduct the sample into the reaction zones. The very small size of the AMT molecule requires microfluidic circuits for binding inhibition test which are more complex than assays used in typical lateral flow tests. The aim of this work is, first, to determine suitable laser scan procedures allowing to adjust the local energy distributions and second, to develop a stripe design for a controlled fluid transport without crosstalk between the microchannels.
The understanding of the initial cell adhesion to biomaterials is crucial for the survival of implants. The manifold possibilities to tailor an implant surface and the diverse requirements for different implant applications necessitate a timesaving and highly parallelized analytical methodology. Due to its intrinsic advantages (label-free, time-resolved, robust against temperature fluctuations, and particularly the multiplexing possibilities), single colour reflectometry (SCORE) is used for the first time to investigate cell adhesion to different extracellular matrix protein-coated surfaces. The excellent correlation between the novel SCORE technology and well-established reference methods proves that the results obtained by using this direct optical method are able to reflect the cell binding processes at the transducer surface. Additionally, the high time resolution of SCORE revealed the differences in the adhesion behaviour of the cells on the different extracellular matrix protein-coated glass slides during the initial adsorption phase and during the spreading of the cells on the surfaces. Therefore, we conclude that SCORE is a perfectly suited methodology for studying the entire cell adsorption process, including morphological changes, and shows great potential for other cell-based sensing applications.
In contrast to other analytical chemistry journals, Analytical and Bioanalytical Chemistry (ABC) has not only a publisher but it also has a number of European chemistry societies as coowners.One reason for the multiple owners is the origin of ABC, which was originally founded as Zeitschrift für Analytische Chemie (Journal for Analytical Chemistry) by Karl Remigius Fresenius nearly 160 years ago.In 1990, Wilhelm Fresenius changed the journal's name to Fresenius' Journal of Analytical Chemistry to emphasize the international reputation of the journal, which received its first submissions in English in the 1950s [1].In the mid-1990s, ten European chemical societies and two commercial publishers established a collaboration "to provide a combination of excellent scientific quality, reasonable subscription rates and high commercial efficiency… with the intention of publishing the best chemistry from Europe and the rest of the world, while promoting and preserving the desirable and necessary diversity of the scientific publications" [2].When Fresenius' Journal of Analytical Chemistry was sold in