Conclusions: Since FIF technique was simple and achieved reasonable dosimetric results, it is recommended for treating right breast cancer.Because of the highly conformal and homogenous target dose, HTis recommended for breast cancer patients with SCF lymph nodes involvement and patients with chest wall target crossed midline and/or with concave chest wall.Both tomotherapy techniques were more favourable for left breast cancer as good target dosimetry was maintained.The advantages of TomoDirect might outweigh its inferior treatment delivery efficiency and provide an alternative treatment strategy only for patients require maximum sparing of OARs.
The reproducibility of 3-dimensional (3D) conformal therapy in localized prostate cancer was studied in 14 patients, based on retrospective analysis of 196 anteroposterior-posteroanterior (AP/PA) and lateral portal images. The patients were treated supine without rigid immobilization using six isocentric coplanar conformal fields. Three different observers independently compared the portal and simulation images, determining the deviation of each portal film from the corresponding simulation film. No significant deviations were observed in the cephalo-caudal or lateral axes (0 mm median values). However, a systematic median shift of 5 mm (0 to +10, range) was observed in the anteroposterior direction, presumably as a consequence of a sagging in the treatment couch under the patient's weight. After modification of the treatment couch, no further systematic anteroposterior shifts have been observed. These results demonstrate that the daily setup of conformal prostate irradiation fields can be performed with acceptable reproducibility without the use of special immobilization devices.
We have studied the value of additional immune suppression in BMT conditioning regimens in 45 patients with leukemia and 4 with myelodysplastic syndrome allografted between 1984 and 1991. A dose of 6 Gy total lymphoid irradiation (TLI) was delivered to 12 of 24 and 15 of 25 patients conditioned with 10 Gy and 12 Gy total body irradiation (TBI), respectively. Thirteen patients also received methylprednisolone (MP) before BMT to enhance immunosuppression. Differences in immunosuppression between the TBI with or without TLI or MP regimens and the influence of different levels of graft T cell depletion were measured in terms of transplant rejection, and complete versus mixed chimerism. The treatment-related complications were evaluated in terms of GVHD and incidence of pneumonitis. The overall transplant rejection rate was 6% (3 of 49). Complete chimerism was not significantly modified by increasing the TBI dose or by additional TLI (p > 0.10) but was more often seen in patients receiving MP given as pre-transplant immunosuppressor booster (p = 0.01). The incidence of GVHD was only influenced by the level of T cell depletion (p = 0.003). All 49 patients received a TBI lung dose in the range 9.5-10 Gy. A crude pneumonitis range of 19% (9 of 47 evaluable patients) was found. Neither the addition of TLI, MP nor the T cell depletion influenced the lung toxicity rate (p > 0.10) but pneumonitis was more frequent in patients with GVHD (p = 0.005).