Background Substrate mapping has highlighted the importance of targeting diastolic conduction channels and late potentials during ventricular tachycardia (VT) ablation. State-of-the-art multipolar mapping catheters have enhanced mapping capabilities. The purpose of this study was to investigate whether long-term outcomes were improved with the use of a HD Grid mapping catheter combining complementary mapping strategies in patients with structural heart disease VT. Methods Consecutive patients underwent VT ablation assigned to either HD Grid, Pentaray, Duodeca, or point-by-point (PbyP) RF mapping catheters. Clinical endpoints included recurrent anti-tachycardia pacing (ATP), appropriate shock, asymptomatic non-sustained VT, or all-cause death. Results Seventy-three procedures were performed (33 HD Grid, 22 Pentaray, 12 Duodeca, and 6 PbyP) with no significant difference in baseline characteristics. Substrate mapping was performed in 97% of cases. Activation maps were generated in 82% of HD Grid cases (Pentaray 64%; Duodeca 92%; PbyP 33% ( p = 0.025)) with similar trends in entrainment and pace mapping. Elimination of all VTs occurred in 79% of HD Grid cases (Pentaray 55%; Duodeca 83%; PbyP 33% ( p = 0.04)). With a mean follow-up of 372 ± 234 days, freedom from recurrent ATP and shock was 97% and 100% respectively in the HD Grid group (Pentaray 64%, 82%; Duodeca 58%, 83%; PbyP 33%, 33% (log rank p = 0.0042, p = 0.0002)). Conclusions This study highlights a step-wise improvement in survival free from ICD therapies as the density of mapping capability increases. By using a high-density mapping catheter and combining complementary mapping strategies in a strict procedural workflow, long-term clinical outcomes are improved.
Implantable cardiac defibrillators (ICDs) can prevent sudden cardiac death, but the risk of recurrent ventricular arrhythmia (VA) and ICD shocks persist. Strategies to minimise such risks include medication optimisation, device programming and ventricular tachycardia (VT) ablation. Whether the choice of these interventions at follow-up are influenced by factors such as the type of arrhythmia or ICD therapy remains unclear. To investigate this, we evaluated ICD follow-up strategies in a real-world population with primary and secondary prevention ICDs. REFINE-VT (Real-world Evaluation of Follow-up strategies after Implantable cardiac-defibrillator therapies in patients with Ventricular Tachycardia) is an observational study of 514 ICD recipients recruited between 2018 and 2019. We found that 77 patients (15%) suffered significant VA and/or ICD therapies, of whom 26% experienced a second event; 31% received no intervention. We observed an inconsistent approach to the choice of strategies across different types of arrhythmias and ICD therapies. Odds of intervening were significantly higher if ICD shock was detected compared with anti-tachycardia pacing (odds ratio [OR] 8.4, 95% confidence interval [CI] 1.7 to 39.6, p=0.007). Even in patients with two events, the rate of escalation of antiarrhythmics or referral for VT ablation were as low as patients with single events. This is the first contemporary study evaluating how strategies that reduce the risk of recurrent ICD events are executed in a real-world population. Significant inconsistencies in the choice of interventions exist, supporting the need for a multi-disciplinary approach to provide evidence-based care to this population.