Obesity is a major risk factor for the incidence and progression of atrial fibrillation (AF), negatively impacting AF ablation outcomes. Weight loss in obese patients prior to AF ablation may improve quality of life (QoL) and AF ablation success rates.
Indications for atrial fibrillation (AF) ablation in current ACC/HRS and ESC guidelines are different for paroxysmal and persistent AF patients. Although previous research has established that the recurrence rate after AF ablation is lower in paroxysmal AF patients, there is little data on differences in post-ablation improvement of quality of life (QoL) and AF-related symptoms.
INTRODUCTION:Radiofrequency (RF) atrial fibrillation (AF) ablation using a catheter dragging technique may shorten procedural duration and improve durability of pulmonary vein isolation (PVI) by creating uninterrupted linear ablation lesions. We compared a novel AF ablation approach guided by Grid annotation allowing for "drag lesions" with a standard point-by-point ablation approach in a single-center randomized study.METHODS:Eighty-eight paroxysmal or persistent AF patients were randomized 1:1 to undergo RF-PVI with either a catheter dragging ablation technique guided by Grid annotation or point-by-point ablation guided by Ablation Index (AI) annotation. In the Grid annotation arm, ablation was visualized using 1 mm³ grid points coloring red after meeting predefined stability and contact force criteria. In the AI annotation arm, ablation lesions were created in a point-by-point fashion with AI target values set at 380 and 500 for posterior/inferior and anterior/roof segments, respectively. Patients were followed up for 12 months after PVI using ECGs, 24-h Holter monitoring and a mobile-based one-lead ECG device.RESULTS:Procedure time was not different between the two randomization arms (Grid annotation 71 ± 19 min, AI annotation 72 ± 26 min, p = .765). RF time was significantly longer in the Grid annotation arm compared with the AI annotation arm (49 ± 8 min vs. 37 ± 8 min, respectively, p < .001). Atrial tachyarrhythmia recurrence was documented in 10 patients (23%) in the Grid annotation arm compared with 19 patients (42%) in the AI annotation arm with time to recurrence not reaching statistical significance (p = .074).CONCLUSIONS:This study shows that a Grid annotation-guided dragging approach provides an alternative to point-by-point RF-PVI using AI annotation.
BACKGROUND:A significant number of patients experience recurrent atrial fibrillation (AF) after ablation. Various risk scores have been described that may predict outcomes after AF ablation. In this study, we aimed to compare ten previously described risk scores with regard to their predictive value for post-ablation AF recurrence and procedural complications. METHODS:A total of 482 AF patients (63% paroxysmal AF, 66% male, mean age 62 ± 9 years) undergoing initial radiofrequency pulmonary vein isolation (PVI) were included in the present analysis. Prior to ablation, all patients underwent both transthoracic echocardiography (TTE) and either cardiac CT imaging or CMR imaging. The following risk scores were calculated for each patient: APPLE, ATLAS, BASE-AF2, CAAP-AF, CHADS2, CHA2DS2-VASc, DR-FLASH, HATCH, LAGO and MB-LATER. RESULTS:Median follow-up was 16 (12-31) months. AF recurrence after a 90-day blanking period was observed in 199 patients (41%), occurring after a median of 183 (124-360) days. AF recurrence was less frequent in paroxysmal AF patients compared to non-paroxysmal AF patients (34% vs. 54%, p < 0.001). Overall periprocedural complication rate was 6%. All scores, except the HATCH score, demonstrated statistically significant but poor predictive value for recurrent AF after ablation (area under curve [AUC] 0.553-0.669). CHA2DS2-VASc and CAAP-AF were the only risk scores with predictive value for procedural complications (AUC 0.616, p = 0.043; AUC 0.615, p = 0.044; respectively). CONCLUSIONS:Currently available risk scores perform poorly in predicting outcomes after AF ablation. These data suggest that the utility of these scores for clinical decision-making is limited.
BACKGROUND:Although Ablation Index (AI)-guided ablation facilitates creation of lesions of consistent depth, pulmonary vein (PV) reconnection is still commonly observed after AI-guided pulmonary vein isolation (PVI). The present study aimed to investigate the impact of local left atrial wall thickness on the incidence of acute PV reconnection after AI-guided atrial fibrillation (AF) ablation.METHODS AND RESULTS:Seventy patients (63% paroxysmal AF, 67% male, mean age 63 ± 8 years) who underwent preprocedural CT imaging and AI-guided AF ablation were studied. Occurrence of acute PV reconnection after initial PVI was assessed after a 30-minute waiting period. Ablation procedures were retrospectively analyzed and each ablation circle was subdivided into 8 segments. Minimum AI, force-time integral, contact force, ablation duration, power, impedance drop and maximum interlesion distance were determined for each segment. PV antrum wall thickness was assessed for each segment on reconstructed CT images based on patient-specific thresholds in Hounsfield Units. Acute reconnection occurred in 27/1120 segments (2%, 15 anterior/roof, 12 posterior/inferior) in 19/140 ablation circles (14%). Reconnected segments were characterized by a greater local atrial wall thickness, both in anterior/roof (1.87 ± 0.42 vs. 1.54 ± 0.42 mm; p < 0.01) and posterior/inferior (1.43 ± 0.20 vs. 1.16 ± 0.22 mm; p < 0.01) segments. Minimum AI, force-time integral, contact force, ablation duration, power, impedance drop and maximum interlesion distance were not associated with acute reconnection.CONCLUSIONS:Local atrial wall thickness is associated with acute pulmonary vein reconnection after AI-guided PVI. Individualized AI targets based on local wall thickness may be of use to create transmural ablation lesions and prevent PV reconnection after PVI.
BACKGROUND:During pulmonary vein isolation (PVI), nonisolation after initial encircling of the pulmonary veins (PVs) may be due to gaps in the initial ablation line, or alternatively, earliest PV activation may occur on the intervenous carina and ablation within the wide-area circumferential ablation (WACA) circle is needed to eliminate residual conduction. This study investigated prognostic implications and predictors of gap-related persistent conduction (gap-RPC) and carina-related persistent conduction (carina-RPC) during PVI.METHODS AND RESULTS:Two hundred fourteen atrial fibrillation (AF) patients (57% paroxysmal, 61% male, mean age 62 ± 9 years) undergoing first contact force-guided radiofrequency PVI were studied. Preprocedural cardiac computed tomography imaging was used to assess left atrial and PV anatomy. PVI was assessed directly after initial WACA circle creation, after a minimum waiting period of 30 minutes, and after adenosine infusion. Persistent conduction was targeted for additional ablation and classified as gap-RPC or carina-RPC, depending on the earliest activation site. The 1-year AF recurrence rate was higher in patients with gap-RPC (47%) compared to patients without gap-RPC (28%; P = .003). No significant difference in 1-year recurrence rate was found between patients with carina-RPC (37%) and patients without carina-RPC (31%; P = .379). Multivariate analyses identified paroxysmal AF and WACA circumference as independent predictors of gap-RPC, whereas carina width and WACA circumference correlated with carina-RPC.CONCLUSIONS:Gap-RPC is associated with increased AF recurrence risk after PVI, whereas carina-RPC does not predict AF recurrence. Moreover, gap-RPC and carina-RPC have different correlates and may thus have different underlying mechanisms.