The outbreak of severe acute respiratory syndrome (SARS) was caused by a newly identified coronavirus (SARS-CoV) in 2003. To detect early SARS-CoV infection, a one-step, real-time quantitative reverse transcription-polymerase chain reaction (RT-PCR) assay was developed that could simultaneously detect nucleocapsid (N), membrane M, and spike (S) genes of SARS-CoV with the same PCR condition using either Applied Biosystems (ABI) Prism 7700 Sequence Detection System or Roche LightCycler. The sensitivity of this assay was evaluated using cell culture-derived viruses, in vitro transcribed viral RNA, and clinical specimens. The SARS-S, -M, and -N primer/probe sets described in this paper could detect one to ten copies of in vitro transcribed S, M, and N RNA per test using both the ABI and Roche assay systems. The relative sensitivities for detecting cell culture-derived SARS-CoV were 0.01, 0.01, and 0.001 PFU/test, respectively. It showed that SARS-N has comparable detection efficiencies to SARS2 and SARS3 which are primers sets designed by Centers for Disease Control and Prevention. In addition, SARS-S and SARS-M also demonstrated equivalent sensitivity to the commercially available RealArt HPA-Coronavirus reagents (Artus). The relative sensitivity of these primer/probe sets was also examined using human sera spiked viruses and clinical specimens from four confirmed SARS patients. Similar results as above were obtained. Specificity tests and sequence alignment showed that these primer/probe sets annealed perfectly to 31 isolates of SARS-CoV; and there was no cross detection with other coronaviruses and human respiratory tract-associated viruses. Therefore, not only is it compatible with the ABI and Roche systems, this multiple-gene detection assay also has the merit of being a rapid, safe, sensitive, and specific tool for accurate diagnosis of SARS-CoV infection.
A rapid, sensitive, and accurate laboratory diagnostic test is needed for distinguishing Japanese encephalitis virus (JEV) from other diseases featuring similar clinical symptoms and also for preventing potential outbreaks. In this study, a TaqMan reverse transcription (RT)‐polymerase chain reaction (PCR) assay was developed for rapid detection and quantification of the viral RNA of various JEV strains. A consensus JEV NS3 region was chosen to design the primers and the TaqMan probe. The JEV TaqMan assay used the EZ‐r TtH RT‐PCR system featuring advantages such as a one‐step, high‐temperature RT reaction modality and preventing carry‐over contamination. The sensitivity of the JEV TaqMan assay for detecting in vitro‐transcribed JEV NS3 RNA was estimated to be one to five copies of RNA per reaction. For cultured JE virions, less than 40 plaque forming unit (PFU)/ml of virus load (corresponding to 0.07 PFU/test) could be detected. In addition, the JEV TaqMan assay could detect all seven strains of JEV tested, but provided negative results for nine other flaviviruses and encephalitis viruses tested. The JEV TaqMan assay demonstrated greater sensitivity and specificity than traditional RT‐PCR methods as has been previously reported. The application of the JEV TaqMan assay herein has been shown to the sensitive detection of the JEV from both mosquito pools and also JEV‐spiking human blood. The assay should be of use in diagnostic laboratory conduct and could be used to replace or complement time‐consuming viral‐culture methods, thus achieving more rapid, sensitive, and highly specific identification of JEV infection. J. Med. Virol. 74:589–596, 2004. © 2004 Wiley‐Liss, Inc.