The Young-Koppel model (YK) describes comprehensively the interaction of slow neutrons with diatomic gases such as H_2 and D_2. This paper reports on the first experimental results of ultracold neutron (UCN) scattering over a wide temperature range vindicating the YK model for gaseous D_2 and showing an important difference in the temperature dependence to a low-energy low-temperature approximation (LETA). LETA is confirmed, however, to be valid for monoatomic gases such as Ne. Calculated cross sections for other noble gases were also confirmed for ultracold neutrons. Finally, the total cross section of UCNs in H_2 gas was measured and analyzed applying the Young-Koppel model, however, in a more limited temperature range, confirming the theoretical prediction.
High-precision searches for an electric dipole moment of the neutron (nEDM) require stable and uniform magnetic field environments. We present the recent achievements of degaussing and equilibrating the magnetically shielded room (MSR) for the n2EDM experiment at the Paul Scherrer Institute. We present the final degaussing configuration that will be used for n2EDM after numerous studies. The optimized procedure results in a residual magnetic field that has been reduced by a factor of two. The ultra-low field is achieved with the full magnetic-field-coil system, and a large vacuum vessel installed, both in the MSR. In the inner volume of ∼ 1.4 m^3 , the field is now more uniform and below 300 pT. In addition, the procedure is faster and dissipates less heat into the magnetic environment, which in turn, reduces its thermal relaxation time from 12 h down to 1.5 h .
We determined the ultracold neutron (UCN) production rate by superthermal conversion in the solid deuterium (sD$_2$) moderator of the UCN source at the Paul Scherrer Institute (PSI). In particular, we considered low amounts of less than $20\,$mol of D$_2$, deposited on the cooled moderator vessel surfaces in thin films of a few mm thickness. We measured the isotopic ($ c_\text{HD} < 0.2 \, \% $) and isomeric ($ c_\text{para} \le 2.7 \, \% $) purity of the deuterium to conclude that absorption and up-scattering at $5\,$K have a negligible effect on the UCN yield from the thin films. We compared the calculated UCN yield based on the previously measured thermal neutron flux from the heavy water thermal moderator with measurements of the UCN count rates at the beamports. We confirmed our results and thus demonstrate an absolute characterization of the UCN production and transport in the source by simulations.
We present a novel Active Magnetic Shield (AMS), designed and implemented for the n2EDM experiment at the Paul Scherrer Institute. The experiment will perform a high-sensitivity search for the electric dipole moment of the neutron. Magnetic-field stability and control is of key importance for n2EDM. A large, cubic, 5 m side length, magnetically shielded room (MSR) provides a passive, quasi-static shielding-factor of about 10^5 for its inner sensitive volume. The AMS consists of a system of eight complex, feedback-controlled compensation coils constructed on an irregular grid spanned on a volume of less than 1000 m ^3 around the MSR. The AMS is designed to provide a stable and uniform magnetic-field environment around the MSR, while being reasonably compact. The system can compensate static and variable magnetic fields up to ± 50 T (homogeneous components) and ± 5 T/m (first-order gradients), suppressing them to a few T in the sub-Hertz frequency range. The presented design concept and implementation of the AMS fulfills the requirements of the n2EDM experiment and can be useful for other applications, where magnetically silent environments are important and spatial constraints inhibit simpler geometrical solutions.
The ultracold neutron (UCN) source at the Paul Scherrer Institute (PSI) provides high intensities of storable neutrons for fundamental physics experiments. The neutron velocity spectrum parallel to the beamline axis was determined by time-of-flight spectroscopy using a neutron chopper. In particular, the temporal evolution of the spectrum during neutron production and UCN storage in the source storage volume was investigated and compared to Monte Carlo simulation results. A softening of the measured spectrum from a mean velocity of 7.7(1)–5.1(1) m s^-1 occurred within the first 30 s after the proton beam pulse had impinged on the spallation target. A spectral hardening was observed over longer time scales of one measurement day, consistent with the effect of surface degradation of the solid deuterium moderator.
Magnetic Johnson-Nyquist noise (JNN) originating from metal electrodes, used to create a static electric field in neutron electric-dipole-moment (nEDM) experiments, may limit the sensitivity of measurements. We present here the first dedicated study on JNN applied to a large-scale long-measurement-time experiment with the implementation of a co-magnetometry. In this study, we derive surface- and volume-averaged root-mean-square normal noise amplitudes at a certain frequency bandwidth for a cylindrical geometry. In addition, we model the source of noise as a finite number of current dipoles and demonstrate a method to simulate temporal and three-dimensional spatial dependencies of JNN. The calculations are applied to estimate the impact of JNN on measurements with the new apparatus, n2EDM, at the Paul Scherrer Institute. We demonstrate that the performances of the optically pumped 133 Cs magnetometers and 199 Hg co-magnetometers, which will be used in the apparatus, are not limited by JNN. Further, we find that in measurements deploying a co-magnetometer system, the impact of JNN is negligible for nEDM searches down to a sensitivity of 4 × 10 − 28 e · cm in a single measurement; therefore, the use of economically and mechanically favored solid aluminum electrodes is possible.