Background:Grab bars are a multi-function bathing tool. While grab bars are commonly recommended by rehabilitation professionals, existing literature regarding optimal grab bar locations is focused on preference rather than function. Objective:This study aimed to evaluate grab bar grasp location on 8 grab bar configurations during bathtub exit, with and without balance loss, and sit-to-stand (STS) from a bath seat. Methods:Motion capture was used to evaluate grasp location during bathing activities in 28 older (65+ years) and 37 younger (18-35 years) adults. Grasp location was compared between age groups and balance loss conditions using ANOVA, and correlated with body height. Results:Vertical grasp location varied from close to the bathtub rim to more than 1 meter above the bathtub rim (maximum 22.4 cm), while horizontal grasp location was close to the bathtub rim during bathtub exit, and close to the bath seat during STS. Young adult participants grasped 9.4% lower on vertical grab bars during perturbation trials than nonperturbation trials (P<.01). Body height was positively correlated with grasp height on a vertical grab bar during nonperturbation trials (r=0.67, P<.01), and negatively correlated with grasp distance on a low horizontal grab bar during STS (r=-0.37, P=.03). Conclusions:Grab bar grasp location varied between proactive and reactive grasp scenarios and was linked to user height for some situations. These findings may be used to guide the selection of a grab bar installation location to support multiple bathing tasks.
BackgroundSuction cup handholds are sometimes recommended by Occupational Therapists for bathing transfers when permanent grab bars are not feasible. The efficacy of suction cup handholds on typical bathroom surfaces is unknown.PurposeThis study evaluated the efficacy and failure characteristics of two brands of suction cup handholds on six typical bathtub wall surfaces, under environmental and loading conditions associated with bathing.MethodEighteen suction cup handholds underwent controlled longevity testing under wet and dry conditions in separate sessions. Handhold efficacy was evaluated through (a) visual inspection, (b) manual manipulation, and (c) controlled loading, with days to failure and other failure details as outcome measures.FindingsNo handhold-wall sample combinations were effective over the 28 day test period, with at least one handhold on each wall sample failing on day one. Handhold failure was most frequently due to sliding along the wall surface, and occurred most frequently during manual manipulation testing.ConclusionHandhold efficacy was poor in a controlled experimental environment. These results can inform clinicians of the risks suction cup handholds pose and assist in clinical recommendations against their use.
Grab bars facilitate bathing and reduce the risk of falls during bathing. Suction cup handholds and rim-mounted tub rails are an alternative to grab bars. The objective of this study was to determine whether older adults could install handholds and tub rails effectively to support bathing transfers. Participants installed rim-mounted tub rails and suction cup handholds in a simulated bathroom environment. Installation location and mechanical loading performance were evaluated. Participant perceptions during device installation and a bathing transfer were characterized. While 85% of suction cup handholds met loading requirements, more than half of participants installed the suction cup handhold in an unexpected location based on existing guidance documents. No rim-mounted tub rails were successfully installed. Participants were confident that the devices had been installed effectively. Suction cup handholds and rim mounted tub rails are easy to install, but clients may need additional guidance regarding where, and how to install them.
Background: Exploring the use of minimum marker sets is important for balancing the technical quality of motion capture with challenging data collection environments and protocols. While minimum marker sets have been demonstrated to be appropriate for evaluation of some motion patterns, there is limited evidence to support model choices for abrupt, asymmetrical, non-cyclic motion such as balance disturbance during a bathtub exit task. Research question: How effective are six models of reduced complexity for the estimation of centre of mass (COM) displacement and velocity, relative to a full-body model. Methods: Eight participants completed a bathtub exit task. Participants received a balance perturbation as they crossed the bathtub rim, stepping from a soapy wet bathtub to a dry floor. Six reduced models were developed from the full, 72-marker, 12 segment 3D kinematic data set. Peak displacement and velocity of the body COM, and RMSE (relative to the full-body model) for displacement and velocity of the body COM were determined for each model. Results: Main effects were observed for peak right, left, anterior, posterior, upwards and downwards motion, and peak left, anterior, posterior, upwards and downwards velocity. Time-varying (RMSE) was smaller for models including the thighs than models not containing the thighs. In contrast, inclusion of upper arm, forearm, and hand segments did not improve model performance. The model containing the sacrum marker only consistently performed the worst across peak and RMSE metrics. Significance: Findings suggest a simplified centre of mass model may adequately capture abrupt, asymmetrical, non-cyclic tasks, such as balance disturbance recovery during obstacle crossing. A reduced kinematic model should include the thighs, trunk and pelvis segments, although models that are more complex are recommended, depending on the metrics of interest.
Hip fractures are a severe health concern among older adults. While anthropometric factors have been shown to influence hip fracture risk, the low fidelity of common body composition metrics (e.g. body mass index) reduces our ability to infer underlying mechanisms. While simulation approaches can be used to explore how body composition influences impact dynamics, there is value in experimental data with human volunteers to support the advancement of computational modeling efforts. Accordingly, the goal of this study was to use a novel combination of subject-specific clinical imaging and laboratory-based impact paradigms to assess potential relationships between high-fidelity body composition and impact dynamics metrics (including load magnitude and distribution and pelvis deflection) during sideways falls on the hip in human volunteers. Nineteen females (<35 years) participated. Body composition was assessed via DXA and ultrasound. Participants underwent low-energy (but clinically relevant) sideways falls on the hip during which impact kinetics (total peak force, contract area, peak pressure) and pelvis deformation were measured. Pearson correlations assessed potential relationships between body composition and impact characteristics. Peak force was more strongly correlated with total mass (r = 0.712) and lean mass indices (r = 0.510-0.713) than fat mass indices (r = 0.401-0.592). Peak deflection was positively correlated with indices of adiposity (all r > 0.7), but not of lean mass. Contact area and peak pressure were positively and negatively associated, respectively, with indices of adiposity (all r > 0.49). Trochanteric soft tissue thickness predicted 59 % of the variance in both variables, and was the single strongest correlate with peak pressure. In five-of-eight comparisons, hip-local (vs. whole body) anthropometrics were more highly associated with impact dynamics. In summary, fall-related impact dynamics were strongly associated with body composition, providing support for subject-specific lateral pelvis load prediction models that incorporate soft tissue characteristics. Integrating soft and skeletal tissue properties may have important implications for improving the biomechanical effectiveness of engineering-based protective products.
Background. Grab bars are used to support bathing tasks. Sometimes, temporary rim-mounted grab bars may be preferred over permanent wall-mounted grab bars. Purpose. We compared postural requirements, applied loads, and user perceptions between two configurations of rim-mounted grab bars, a vertical wall-mounted grab bar, and a no-grab bar condition. Method. Ten adults entered and exited a simulated bathing environment. Trunk flexion was evaluated via 3D kinematics, while load cells mounted to the grab bars facilitated the evaluation of applied loads. Participants rated each condition on perceived safety, comfort, effectiveness, and ease of use. Findings. Rim-mounted grab bars resulted in greater trunk flexion and greater applied loads and were less favorably perceived. Implications. The rim-mounted grab bars included in this study may induce challenging postural demands and loading scenarios, and occupational therapists should consider whether they meet the needs of their clients.
Given the prevalence and severity of bathroom falls and injuries across age groups, there is growing interest in policy-level approaches to bathroom fall prevention. Grab bars reduce fall risk during bathing transfers and improve bathing accessibility for adults of all ages and abilities. However, they are frequently absent from bathing environments, even in the homes of individuals who have a specific need for a grab bar. While mandatory bathroom grab bar installation has been suggested, it is unclear whether this would be supported by Canadians. The purpose of this study was to characterize Canadian public perceptions on the installation and use of grab bars in home bathrooms. We surveyed 443 Canadians about whether they currently had a grab bar and their perspectives on grab bar policy. 65.4% of respondents did not have a grab bar. However, 88.5% of respondents would allow a grab bar to be installed in their bathroom at no cost to them, only 11.5% of respondents would object to grab bar installation becoming mandatory in new builds, and 85.6% of respondents would use a grab bar if it were installed in their bathroom. Responses were affected by age (in four groups: 18–39, 40–59, 60–79, and 80+ years), self-reported impairment, and home ownership status. Older adults, respondents who reported having impairments, and home owners were more likely to respond favorably toward grab bars. Based on these results, the majority of Canadians would respond positively to policy mandating bathroom grab bars in new homes.
Objective This study evaluated the hazard (risk of unrecovered balance loss and hazardous fall) and strategies associated with grab bar use, compared to no grab bar use, during unexpected balance loss initiated whilst exiting a bathtub. Background While independent bathing is critical for maintaining self-sufficiency, injurious falls during bathing transfer tasks are common. Grab bars are recommended to support bathing tasks, but no evidence exists regarding fall prevention efficacy. Method Sixty-three adults completed a hazardous bathtub transfer task, experiencing an unpredictable external balance perturbation while stepping from a slippery bathtub to a dry surface. Thirty-two were provided a grab bar, while 31 had no grab bar available. Slips and grab bar use were recorded via four video cameras. Slip occurrence and strategy were identified by two independent video coders. Results Participants who had a grab bar were 75.8% more likely to recover their balance during the task than those who did not have a grab bar. Successful grab bar grasp was associated with balance recovery in all cases. Attempts to stabilize using other environmental elements, or using internal strategies only, were less successful balance recovery strategies. Grab bar presence appeared to cue use of the environment for stability. Proactive grasp and other strategies modified grasping success. Conclusion Grab bars appear to provide effective support for recovery from unexpected balance loss. Grab bar presence may instigate development of fall prevention strategies prior to loss of balance. Application Bathroom designs with grab bars may reduce frequency of fall-related injuries during bathing transfer tasks.
In-vivo fall simulations generally evaluate hip fracture risk through differences in impact force magnitude; however, the distribution of force over the hip likely modulates loading and subsequent injury risk of the underlying femur. The current study characterized impact force distribution over the hip during falls, and the influence of biological sex and trochanteric soft tissue thickness (TSTT). Forty young adults completed fall simulation protocols (FSP) including highly controlled vertical pelvis and more dynamic kneeling and squat releases. At the instant of peak force, percentage of impact force applied in a circular region (r = 5 cm) centered over the greater trochanter (FGT%) was determined to characterize force localization. To assess the need for anatomically aligned pressure analysis, this process was repeated utilizing peak pressure location as a surrogate for the greater trochanter (FPP%). FGT% was 10.8 and 21.9% greater in pelvis release than kneeling and squat releases respectively. FGT% was 19.1 and 30.4% greater in males and low-TSTT individuals compared to females and high-TSTT individuals. TSTT explained the most variance (43.7-55.3%) in FGT% across all protocols, while sex explained additional variance (5.3-19.0%) during dynamic releases. In all FSP, TSTT-groups and sexes, average peak pressure location was posterior and distal to the GT. FPP% overestimated FGT% by an average of 15.7%, highlighting the need for anatomically aligned pressure analysis. This overestimation was FSP and sex dependent, minimized during pelvis release and in males. The data have important implications from clinical and methodological perspectives, and for implementation in tissue-level computational models.
Stair design can influence the risk of stair falls. Stair nosings are intended to provide greater foot accommodation, although to date little is known about how the nosing shape can affect foot trajectory during stair ambulation. This study investigates the impact of different nosing shapes (round, square, tapered, and no nosing) on foot clearance and overhang measures during stair ascent and descent among healthy and post-stroke older adults. Slower cadence in ascent and descent, and greater foot overhang during descent highlighted the increased risk of stair falls for persons with chronic stroke. For both healthy and post-stroke participants, the tapered and round nosing shapes resulted in the largest horizontal foot clearance, and smallest foot overhang, respectively. However, given the greater step-to-step variability detected with round nosings, the tapered nosing presents as the safest choice among all evaluated designs. The results of this work can be used to inform architectural and accessible design standards for a safer built environment.
Fall simulations provide insight into skin-surface impact dynamics but have focused on vertical force magnitude. Loading direction and location (relative to the femur) likely influence stress generation. The current study characterized peak impact vector magnitude, orientation, and center of pressure over the femur during falls, and the influence of biological sex and trochanteric soft tissue thickness (TSTT). Forty young adults completed fall simulations including a vertical pelvis release, as well as kneeling and squat releases, which incorporate lateral/rotational motion. Force magnitude and direction varied substantially across fall simulations. Kneeling and squat releases elicited 57.4 and 38.8% greater force than pelvis release respectively, with differences accentuated in males. With respect to the femoral shaft, kneeling release had the most medially and squat release the most distally directed loading vectors. Across all fall simulations, sex and TSTT influenced force magnitude and center of pressure. Force was 28.0% lower in females and was applied more distally than in males. Low-TSTT participants had 16.8% lower force, applied closer to the greater trochanter than high-TSTT participants. Observed differences in skin-surface impact dynamics likely interact with underlying femur morphology to influence stress generation. These data should serve as inputs to tissue-level computational models assessing fracture risk.
Falls during stair descent are dangerous and costly. Contrasting tread edge highlighters improve measures of stair safety, however the necessary contrast level of these interventions has not been investigated. Thirteen older adults (67.7 ± 5.5 years) completed stair descent trials under normal (300lx) and low (30lx) lighting conditions, blurred and normal vision, and four different contrast levels (0%, 30%, 50%, 70%) between the tread edge highlighter and the neighbouring tread surface. Cadence and heel clearance decreased for 0% contrast compared to 50% and 70% contrast conditions, but contrast had no effect on foot overhang. Blurred vision was observed to be a greater factor influencing biomechanical measures of fall risk than low ambient lighting. Results suggest higher contrast highlighters improve measures of safety, even more so during simulated vision impairment, and that at least 50% contrast difference provides adequate visual information for safer stair ambulation.
Introduction: Clinical femoral geometry elements has been linked to epidemiological hip fracture risk [1]. The underlying mechanisms have been attributed to fracture strength [1], however, geometry also influences peak stress magnitude and location [2]. The primary goal of this project was to determine whether clinical femoral geometry elements, previously related to femur fracture tolerance, correlate with simple beam model femoral stresses during a simulated lateral fall. We hypothesized that peak stress would correlate with femur geometry, particularly the angle between the femoral neck and shaft and the femoral neck length.
Hip fractures are a substantive public health issue. Simple mass-spring or mass-spring-damper systems have been utilized to model lateral fall on the hip. However, the biofidelity of these models is questionable as the femur/pelvis system is comprised of complex interactions between biological soft and skeletal tissues. This study investigated how increasing the complexity of contact models (from geometric and damping perspectives) influenced the accuracy of impact dynamics predictions during sideways falls, and the biomechanical sources of errors for each model. Fortysix participants (<35 years) underwent simulated sideways falls which involved their pelvis impacting a force plate with a low (but clinically relevant) velocity of 1 m/s. Simulations implementing five contact models (mass-spring(MS), Voigt(VG), Hertzian (HZ), HuntCrossley(HC), and volumetric(VO)) estimated normal force during impact. Subject-specific input parameters (mass, stiffness, and damping) were incorporated using previouslyderived regression equations. Model predictions were evaluated against subject-specific experimental data to determine five error metrics including: peak force magnitude (Errmax), loading duration (ErrTTP), RMSE error over the impact period (ErrRMSE), impulse (Errimp), and prediction within an experimental corridor (Errcorr)). Peak force estimates were substantively over-predictive for MS and VO, substantively under-predictive for VG, and best for HZ and HC. Timetopeak force and impulse predictions were best for models with damping components (i.e. VG and HC, VO) but significantly over-predictive for MS and HZ. Errcorr and ErrRMSE were substantially improved for HC compared to all other models. Model errors were primarily linked to body composition, particularly body fat, overall body size, and floor-pelvis contact profile. Overall model performance was best for HC compared to all other models. Future model iterations should focus on characterizing the influence of body fat and adjusting contact geometry assumptions approximate shape and size of the floor-pelvis contact profile.
While metrics of pelvis and femur geometry have been demonstrated to influence hip fracture risk, attempts at linking geometry to underlying mechanisms have focused on fracture strength. We investigated the potential effects of femur and pelvis geometry on applied loads during lateral falls on the hip. Fifteen female volunteers underwent DXA imaging to characterize two pelvis and six femur geometric features. Additionally, participants completed low-energy sideways falls on the hip; peak impact force and pressure, contact area, and moment of force applied to the proximal femur were extracted. No geometric feature was significantly associated with peak impact force. Peak moment of force was significantly associated with femur moment arm (p = 0.005). Peak pressure was positively correlated with pelvis width and femur moment arm (p < 0.05), while contact area was negatively correlated with metrics of pelvis width and femur neck length (p < 0.05). This is the first study to link experimental measures of impact loads during sideways falls with image-based skeletal geometry from human volunteers. The results suggest that while skeletal geometry has limited effects on overall peak impact force during sideways falls, it does influence how impact loads are distributed at the skin surface, in addition to the bending moment applied to the proximal femur. These findings have implications for the design of protective interventions (e.g. wearable hip protectors), and for models of fall-related lateral impacts that could incorporate the relationships between skeletal geometry, external load magnitude/distribution, and tissue-level femur loads.
Muscle activation has been demonstrated to influence impact dynamics during scenarios including running, automotive impacts, and head impacts. This study investigated the effects of targeted muscle activation magnitude on impact dynamics during low energy falls on the hip with human volunteers. Fifteen university-aged participants (eight females, seven males) underwent 12 lateral pelvis release trials. Half of the trials were muscle-'relaxed'; in the remaining 'contracted' trials participants isometrically contracted their gluteus medius to 20-30% of maximal voluntary contraction before the drop was initiated onto a force plate. Peak force applied to the femur-pelvis complex averaged 9.3% higher in contracted compared to relaxed trials (F = 6.798, p = .022). Muscle activation effects were greater for females, resulting in (on average) an 18.5% increase in effective pelvic stiffness (F = 5.838, p = .046) and a 23.4% decrease in time-to-peak-force (F = 5.109, p = .042). In the relaxed trials, muscle activation naturally increased during the impact event, reaching levels of 12.8, 7.5, 11.1, and 19.1% MVC at the time of peak force for the gluteus medias, vastus lateralis, erector spinae, and external oblique, respectively. These findings demonstrated that contraction of trunk and hip musculature increased peak impact force across sexes. In females, increases in the magnitude and rate of loading were accompanied (and likely driven) by increases in system stiffness. Accordingly, incorporating muscle activation contributions into biomechanical models that investigate loading dynamics in the femur and/or pelvis during lateral impacts may improve estimate accuracy.
A wide variety of accelerometer systems, with differing sensor characteristics, are used to detect impact loading during physical activities. The study examined the effects of system characteristics on measured peak impact loading during a variety of activities by comparing outputs from three separate accelerometer systems, and by assessing the influence of simulated reductions in operating range and sampling rate. Twelve healthy young adults performed seven tasks (vertical jump, box drop, heel drop, and bilateral single leg and lateral jumps) while simultaneously wearing three tri-axial accelerometers including a criterion standard laboratory-grade unit (Endevco 7267A) and two systems primarily used for activity-monitoring (ActiGraph GT3X+, GCDC X6-2mini). Peak acceleration (gmax) was compared across accelerometers, and errors resulting from down-sampling (from 640 to 100Hz) and range-limiting (to ±6g) the criterion standard output were characterized. The Actigraph activity-monitoring accelerometer underestimated gmax by an average of 30.2%; underestimation by the X6-2mini was not significant. Underestimation error was greater for tasks with greater impact magnitudes. gmax was underestimated when the criterion standard signal was down-sampled (by an average of 11%), range limited (by 11%), and by combined down-sampling and range-limiting (by 18%). These effects explained 89% of the variance in gmax error for the Actigraph system. This study illustrates that both the type and intensity of activity should be considered when selecting an accelerometer for characterizing impact events. In addition, caution may be warranted when comparing impact magnitudes from studies that use different accelerometers, and when comparing accelerometer outputs to osteogenic impact thresholds proposed in literature.
This study sought to compare a new head impact-monitoring device, which is not limited to specific helmet styles, against reference accelerometer measurements. Laboratory controlled impacts were delivered using a linear pneumatic impactor to a Hybrid III headform (HIII) fitted with a football helmet and the impact monitoring device (gForce Tracker-GFT) affixed to the inside of the helmet. Linear regression analyses and absolute mean percent error (MAPE) were used to compare the head impact kinematics measured by the GFT to a reference accelerometer located at the HIII’s center of mass. The coefficients of determination were strong for the peak linear acceleration, peak rotational velocity, and HIC 15 across all impact testing locations ( r 2 = 0.82, 0.94, and 0.70, respectively), but there were large MAPE for the peak linear acceleration and HIC 15 (MAPE = 49 ± 21% and 108 ± 58%). The raw GFT was accurate at measuring the peak rotational velocity at the center of mass of the HIII (MAPE = 9%). Results from the impact testing were used to develop a correction algorithm. The coefficients of determination for all impact parameters improved using the correction algorithm for the GFT ( r 2 > 0.97), and the MAPE were less than 14%. The GFT appears to be a suitable impact-monitoring device that is not limited to specific styles of football helmets, however, correction algorithms will need to be developed for each helmet style.
While underweight fallers suffer the greatest rate of hip and wrist fractures, obese fallers are also susceptible to lower leg and ankle fragility fractures. Differences in balance control mechanisms, control of body segments during a fall, and impact mechanics may help explain these differences. The goal of this study was to determine whether there were differences in fall cause and circumstances between low-body mass index (BMI) and high-BMI older adults who suffered falls. A validated questionnaire was used to analyze real-life fall videos of 25 low-BMI (lowest-available quartile, BMI <20.8) and 25 high-BMI (highest-available quartile, BMI >27.6) older-adult long-term care (LTC) residents to determine the cause and circumstances of each incident. Comparisons were made between BMI groups for the initiation, descent and impact stages of the fall. Low- and high-BMI groups did not differ in number of comorbidities, activity type, mobility aid use, attempts to grasp objects, falling direction, landing direction or impacting segments. Underweight fallers utilized larger stepping responses (X2=8.384, p=0.039). Overweight fallers were more likely to suffer fall due to tripping or stumbling than underweight fallers (X2=3.947, p=0.047). Smaller step responses in overweight fallers may be due to larger limb segment inertia or lower foot-floor clearance, and is less effective for preventing falls. Our results match experimental results and injury patterns reported in literature, with a greater rate of tripping by high-BMI than low-BMI fallers. Tripping falls and smaller step responses could contribute to the generation of larger moments at the ankle prior to impact which may increase ankle injury risk.