OBJECTIVES: This study aimed to evaluate the influence of two nonthermal atmospheric plasma (NTAP) application times and two storage times on the microtensile bond strength (μTBS) to dentin. The influence of NTAP on the mechanical properties of the dentin-resin interface was studied by analyzing nanohardness (NH) and Young's modulus (YM). Water contact angles of pretreated dentin and hydroxyapatite blocks were also measured to assess possible alterations in the surface hydrophilicity upon NTAP. METHODS AND MATERIALS: Forty-eight human molars were used in a split-tooth design (n=8). Midcoronal exposed dentin was flattened by a 600-grit SiC paper. One-half of each dentin surface received phosphoric acid conditioning, while the other half was covered with a metallic barrier and remained unetched. Afterward, NTAP was applied on the entire dentin surface (etched or not) for 10 or 30 seconds. The control groups did not receive NTAP treatment. Scotchbond Universal (SBU; 3M ESPE) and a resin-based composite were applied to dentin following the manufacturer's instructions. After 24 hours of water storage at 37°C, the specimens were sectioned perpendicular to the interface to obtain approximately six specimens or bonded beams (approximately 0.9 mm2 in cross-sectional area) representing the etch-and-rinse (ER) approach and another six specimens representing the self-etch (SE) approach. Half of the μTBS specimens were immediately loaded until failure, while the other half were first stored in deionized water for two years. Three other bonded teeth were selected from each group (n=3) for NH and YM evaluation. Water contact-angle analysis was conducted using a CAM200 (KSV Nima) goniometer. Droplet images of dentin and hydroxyapatite surfaces with or without 10 or 30 seconds of plasma treatment were captured at different water-deposition times (5 to 55 seconds). RESULTS: Two-way analysis of variance revealed significant differences in μTBS of SBU to dentin after two years of water storage in the SE approach, without differences among treatments. After two years of water aging, the ER control and ER NTAP 10-second groups showed lower μTBS means compared with the ER NTAP 30-second treated group. Nonthermal atmospheric plasma resulted in higher NH and YM for the hybrid layer. The influence of plasma treatment in hydrophilicity was more evident in the hydroxyapatite samples. Dentin hydrophilicity increased slightly after 10 seconds of NTAP, but the difference was higher when the plasma was used for 30 seconds. CONCLUSIONS: Dentin NTAP treatment for 30 seconds contributed to higher μTBS after two years of water storage in the ER approach, while no difference was observed among treatments in the SE evaluation. This result might be correlated to the increase in nanohardness and Young's modulus of the hybrid layer and to better adhesive infiltration, since dentin hydrophilicity was also improved. Although some effects were observed using NTAP for 10 seconds, the results suggest that 30 seconds is the most indicated treatment time.
Objective. Dentin biomodification using collagen cross-linkers has been proposed as one of the strategies to improve bond durability of adhesives to dentin. However, literature is not very consistent regarding their benefit, in particular when cross-linkers are applied in clinically realistic application times. This study investigated the effect of three cross-linkers on the mini-interfacial fracture toughness (mini-iFT) of four adhesives bonded to dentin following either etch&rinse (E&R) or self-etch (SE) modes. Methods. 60 molars were randomly divided in accordance with the three variables: crosslinker, adhesive and bonding mode (n = 5). The cross-linkers glutaraldehyde (5 wt%; GA), proanthocyanidin (6.5 wt%; PA), or UVA-activated riboflavin (0.5 wt%; RB), and distilled water(control) were applied on dentin for 60 s after acid-etching (E&R) or before self-etching (SE). The 3-step E&R adhesive (3E&Ra) OptiBond FL (Kerr), the 2-step SE adhesive (2SEa) Clearfil SE Bond 2 (Kuraray Noritake) and the universal adhesives G-Premio Bond (GC) and Prime&Bond Active (Dentsply), the latter two employed in both E&R and SE modes, were applied following the respective manufacturer's instructions. Composite buildups (8 x 8 x 8 mm) were made using Filtek Supreme XTE (3M) prior to 1-week storage in artificial saliva. After the teeth were sectioned into mini-specimens (1.5 x 2.0 x 18 mm), a single notch was prepared at the adhesive-dentin interface. Half of the specimens were immediately loaded until failure by 4-point bending to determine the mini-iFT, while the remaining specimen set was tested upon 6-month aging. Data were statistically analyzed with a linear model (p < 0.05). Results. No significant decrease in mini-iFT was noted only for PA (p < 0.05), while the mini-iFT decreased for both other cross-linkers and in quite a similar way as when solely water (Wa) was applied. Significance. The cross-linker proanthocyanidin (PA) applied in clinically relevant conditions was able to maintain a stable mini-iFT after 6-month aging. The incorporation of UVA-activated riboflavin (RB) and glutaraldehyde (GA) in the dentin-bonding protocol appeared not effective to improve the stability of adhesive-dentin interfaces. (C) 2018 The Academy of Dental Materials. Published by Elsevier Inc. All rights reserved.
OBJECTIVES:To evaluate the effect of different surface treatments on the bond strength to a composite and a polymer-infiltrated ceramic CAD/CAM block after six-month artificial aging.METHODS AND MATERIALS:Two types of CAD/CAM blocks (Cerasmart, GC; Enamic, Vita Zahnfabrik) were cut in slabs of 4-mm thickness, divided into six groups, and subjected to the following surface treatments: group 1: no treatment; group 2: sandblasting (SB); group 3: SB + silane (Si); group 4: SB + Si + flowable composite (see below); group 5: 5% hydrofluoric acid etching (HF) + Si; and group 6: 37% phosphoric acid etching (H3PO4) + Si. Sections of the same group were luted together (n=3: 3 sandwich specimens/group) using a dual-cure self-adhesive cement for all groups, except for the sections of group 4 that were luted using a light-curing flowable composite. After three weeks of storage in 0.5% chloramine at 37°C, the sandwich specimens were sectioned in rectangular microspecimens and trimmed at the interface to a dumbbell shape (1.1-mm diameter). One half of the specimens was subjected to a microtensile bond strength (μTBS) test, and the other half was tested after six months of water storage (aging). Data were statistically analyzed with a linear mixed-effects model for the factors surface treatment, material type, and aging, together with their first-degree interactions (α=0.05).RESULTS:The lowest bond strengths were obtained in the absence of any surface treatment (group 1), while the highest μTBSs were obtained when the surface was roughened by either SB or HF, this in combination with chemical adhesion through Si. Loss in bond strength was observed after six-month aging when either surface roughening or silanization, or both, were omitted.CONCLUSIONS:Both the composite and polymer-infiltrated ceramic CAD/CAM blocks appeared equally bonding-receptive regardless of the surface treatment used. Creating a microretentive surface by either SB or HF, followed by chemical adhesion using Si, is mandatory to maintain the bond strength after six months.
In response to the letter to the editor by Ruse (2016), we confirm that the finite element modeling dimensions were similar to those of the actually tested specimens; the depicted model in Figure 1 is shorter in order to detail the loaded part. During initial loading, stress was not entirely uniformly distributed but concentrated at the actual adhesive-dentin interface (Appendix Fig. 1c, d). Once the crack propagated, stress uniformly distributed (Appendix Fig. 1e, f). Scanning electron microscopy confirmed a parallel crack progression, also witnessed by the observed hackle. We assume that nonuniform stress distribution would have led to premature failures—and, hence, lower values—while our values are higher than those previously reported, though not that substantially, considering the range reported in the review by Söderholm (2010): 1–4 MPa·m and 1–2 MPa·m for dentin and interface specimens, respectively (standard deviations often exceeding 25%). Despite the strongly expressed urge for an interfacial fracture toughness (iFT) approach at the 2009 Academy of Dental Materials meeting (Portland, OR), the technical complexity of fracture toughness testing probably discouraged researchers from producing new fracture toughness data. Triggered by this symposium, we first developed a macro-iFT test (De Munck et al. 2013; De Munck et al. 2015). Here, we introduced a miniiFT version, which appeared almost as feasible as common microtensile bond strength testing; it caused specimens to fail at the actual interface with lower variation (Pongprueksa et al. 2016). We therefore encourage other researchers to pick up this novel approach. Meanwhile, further validation was conducted in the framework of the PhD thesis of Dr. Pongprueksa (2016). Bonding effectiveness can be measured in different ways— in this case, through common bond strength testing but also through an iFT approach. We use bonding effectiveness as a compilation term for the perceived effectiveness of an adhesive to bond. Acknowledgments
Secondary caries (SC) remains a very important problem with composite restorations. The objectives of this study were to test the acid-buffering ability of several restorative materials and to evaluate whether buffering of the restorative material has an impact on the microbial composition of the biofilm. Disk-shaped specimens of conventional composite, composite with surface prereacted glass-ionomer filler particles (so-called giomer), glass-ionomer cement (GIC), amalgam, and hydroxyapatite (HAp) (control) were exposed to aqueous solutions with pH 4, 5, 6, and 7 and to the medium containing bacteria-produced acids, and pH changes were recorded over several days. Next, material specimens were immersed in bacterial growth medium with pH adjusted to 5. After a 24-h incubation, the extracts were collected and inoculated with a cariogenic (Streptococcus mutans) and a noncariogenic (Streptococcus sanguinis) species. The bacterial growth was monitored both in a single-species model by spectrophotometry and in a dual-species model by viability quantitative polymerase chain reaction. Amalgam and HAp showed the strongest acid-buffering ability, followed by the GIC and the giomer, while the conventional composite did not exhibit any buffering capacity. Furthermore, due to the lack of acid-buffering abilities, composite was not able to increase the pH of the medium (pH 5), which, in the absence of antibacterial properties, allowed the growth of S. mutans, while the growth of S. sanguinis, a less aciduric species, was completely inhibited. A similar effect was observed when bacteria were cultured together: there was a higher percentage of S. mutans and lower percentage of S. sanguinis with the conventional composite than with other materials and HAp. In conclusion, conventional composites lack the ability to increase the local pH, which leads to the outgrowth of more acidogenic/aciduric bacteria and higher cariogenicity of the biofilm. Together with lack of antibacterial properties, lack of buffering may account for the higher susceptibility of composites to SC.
The interfacial interaction of veneering ceramic with zirconia is still not fully understood. This study aimed to characterize morphologically and chemically the zirconia–veneering ceramic interface. Three zirconia-veneering conditions were investigated: 1) zirconia–veneering ceramic fired on sandblasted zirconia, 2) zirconia–veneering ceramic on as-sintered zirconia, and 3) alumina–veneering ceramic (lower coefficient of thermal expansion [CTE]) on as-sintered zirconia. Polished cross-sectioned ceramic–veneered zirconia specimens were examined using field emission gun scanning electron microscopy (Feg-SEM). In addition, argon-ion thinned zirconia–veneering ceramic interface cross sections were examined using scanning transmission electron microscopy (STEM)–energy dispersive X-ray spectrometry (EDS) at high resolution. Finally, the zirconia–veneering ceramic interface was quantitatively analyzed for tetragonal-to-monoclinic phase transformation and residual stress using micro-Raman spectroscopy (µRaman). Feg-SEM revealed tight interfaces for all 3 veneering conditions. High-resolution transmission electron microscopy (HRTEM) disclosed an approximately 1.0-µm transformed zone at sandblasted zirconia, in which distinct zirconia grains were no longer observable. Straight grain boundaries and angular grain corners were detected up to the interface of zirconia– and alumina–veneering ceramic with as-sintered zirconia. EDS mapping disclosed within the zirconia–veneering ceramic a few nanometers thick calcium/aluminum-rich layer, touching the as-sintered zirconia base, with an equally thick silicon-rich/aluminum-poor layer on top. µRaman revealed t-ZrO2-to- m-ZrO2 phase transformation and residual compressive stress at the sandblasted zirconia surface. The difference in CTE between zirconia– and the alumina–veneering ceramic resulted in residual tensile stress within the zirconia immediately adjacent to its interface with the veneering ceramic. The rather minor chemical elemental shifts recorded in the veneering ceramic did not suffice to draw definitive conclusions regarding potential chemical interaction of the veneering ceramic with zirconia. Sandblasting damaged the zirconia surface and induced phase transformation that also resulted in residual compressive stress. Difference in CTE of zirconia versus that of the veneering ceramic resulted in an unfavorable residual tensile stress at the zirconia–veneering ceramic interface.
Measurement of interfacial fracture toughness (iFT) is considered a more valid method to assess bonding effectiveness as compared with conventional bond strength testing. Common fracture toughness tests are, however, laborious and require a relatively bulky specimen size. This study aimed to evaluate a new simplified and miniaturized iFT (mini-iFT) test. Four dentin adhesives, representing the main adhesive classes, and 1 glass ionomer cement were applied onto flat dentin. Mini-iFT (1.5 × 2.0 × 16 to 18 mm) and microtensile bond strength (µTBS; 1.5 × 1.5 × 16 to 18 mm) specimens were prepared from the same tooth. For the mini-iFT specimens, a single notch was cut at the adhesive-dentin interface with a 150-µm diamond blade under water cooling; the specimens were loaded until failure in a 4-point bending test setup. Finite element analysis was used to analyze stress distribution during mini-iFT testing. The correlation between the mean mini-iFT and µTBS was examined and found to be significant; a strong positive correlation was found (r2 = 0.94, P = 0.004). Weibull data analysis suggested the mini-iFT to vary less than the µTBS. Both the mini-iFT and the µTBS revealed the same performance order, with the 3-step etch-and-rinse adhesive outperforming the 2-step self-etch and 2-step etch-and-rinse adhesive, followed by the 1-step SE adhesive and, finally, the glass ionomer cement. Scanning electron microscopy failure analysis revealed the adhesive-dentin interface to fail more at the actual interface with the mini-iFT test, while µTBS specimens failed more within dentin and composite. This finding was corroborated by finite element analysis showing stress to concentrate at the interface during mini-iFT loading and crack propagation. In conclusion, the new mini-iFT test appeared more discriminative and valid than the µTBS to assess bonding effectiveness; the latter test nevertheless remains more versatile. Specimen size and workload were alike, making the mini-iFT test a valid alternative for the popular µTBS test.
Objective. The objective of this randomized controlled clinical trial was to evaluate the 13-year clinical performance of a mild two-step self-etch adhesive in non-carious cervical lesions with and without prior selective phosphoric acid-etching of the enamel cavity margins.Methods. A total of 100 non-carious cervical lesions in 29 patients were restored with Clearfil AP-X (Kuraray Noritake). The composite restorations were bonded following two different approaches: (1) application of Clearfil SE Bond (Kuraray Noritake) following a self-etch approach (CSE-NE); (2) selective phosphoric acid-etching of enamel cavity margins before application of Clearfil SE Bond (CSE-E). The restorations were evaluated after 6 months, 1, 2, 3, 5, 8 and 13 years of clinical service regarding retention, marginal integrity and discoloration, caries occurrence, preservation of tooth vitality and post-operative sensitivity.Results. The patient recall rate at 13 years was 62%. Six restorations, 4 of the CSE-NE group and 2 of the CSE-E group, were clinically unacceptable due to loss of retention (1 CSE-NE, 1 CSE-E), a severe marginal defect (2 CSE-NE, 1 CSE-E) and caries occurrence in combination with a severe marginal defect (1 CSE-NE) leading to a clinical success rate of 86% (CSE-NE) and 93% (CSE-E). Ageing of the restorations was characterized by a further increase in the percentage of restorations with a clinically acceptable small marginal defect (CSE-NE: 87%; CSE-E: 83%) and/or superficial marginal discoloration (CSE-NE: 53%; CSE-E: 56%). The presence of small marginal defects (CSE-NE: 86%; CSE-E: 68%) and superficial marginal discoloration (CSE-NE: 41%; CSE-E: 20%) at the incisal enamel side was more frequently noticed in the CSE-NE group than in the CSE-E group. The difference, however, was not statistically significant (McNemar, p >0.05).Signcance. After 13 years, the clinical effectiveness of Clearfil SE Bond in non-carious ClassV lesions remained excellent, with selective acid-etching of the enamel cavity margins only having some minor positive effect on marginal integrity and absence of marginal discoloration. (C) 2015 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.
Objectives: The purpose of this study was to evaluate how evaporation affects the shelf life of a one-bottle universal adhesive.Methods: Three different versions of Scotchbond Universal (SBU, 3M ESPE, Seefeld, Germany) were prepared using a weight-loss technique. SBU0 was left open to the air until maximal weight loss was obtained, whereas SBU50 was left open until 50% of evaporation occurred. In contrast, SBU100 was kept closed and was assumed to contain the maximum concentration of all ingredients. The degree of conversion (DC) was determined by using Fourier transform infrared spectroscopy on different substrates (on dentin or glass plate and mixed with dentin powder); ultimate microtensile strength and microtensile bond strength to dentin were measured as well.Results: DC of the 100% solvent-containing adhesive (SBU100) was higher than that of the 50% (SBU50) and 0% (SBU0) solvent-containing adhesives for all substrates. DC of the adhesive applied onto glass and dehydrated dentin was higher than that applied onto dentin. Even though the ultimate microtensile strength of SBU0 was much higher than that of SBU50 and SBU100, its bond strength to dentin was significantly lower.Conclusions: Evaporation of adhesive ingredients may jeopardize the shelf life of a one-bottle universal system by reducing the degree of conversion and impairing bond strength. However, negative effects only became evident after more than 50% evaporation.
Dental zirconia can no longer be considered un-bondable to tooth tissue. In literature, an increasing number of papers indeed report on the bonding effectiveness of different luting techniques to zirconia. We aimed to disclose general trends in bonding to zirconia by systematically collecting zirconia bond-strength data. A search in PubMed and EMBASE revealed 1,371 bond-strength tests reported on in 144 papers. A macro-shear bond-strength protocol was most frequently used; it revealed significantly lower bond strengths and was less discriminative than the other test methods. Regarding luting technique, the combination of mechanical and chemical pre-treatment appeared particularly crucial to obtain durable bonding to zirconia ceramics. The cement choice was not revealed as a determining factor after aging conditions, as long as composite cement was used. Regarding test protocol, a tensile test appeared more discriminative, particularly when combined with 'water storage' aging.
OBJECTIVES:Despite representing an important component of current dental adhesives, HEMA has been said to negatively influence the long-term stability of adhesion to dentine and enamel. The aim of this randomised clinical trial was to evaluate the 3-year clinical performance of two one-step self-etch adhesives. METHODS:Thirty patients had 175 non-carious cervical lesions restored with composite (Gradia Direct Anterior, GC) using either the HEMA-rich adhesive Clearfil Tri-S Bond (C3S; Kuraray) or the HEMA-free adhesive G-Bond (GB; GC). The restorations were evaluated by two examiners at baseline, 6, 12, 24 and 36 months regarding retention, caries recurrence, marginal integrity and discoloration and post-operative sensitivity. The data were statistically analysed with GEE and McNemar tests (p<0.05). RESULTS:The recall rate at 6 and 12 months was 100% and decreased to 96.7% at 24 and 36 months. At 3 years, the retention rate was 93.8% for C3S and 98.8% for GB (p=0.14). A pairwise comparison showed no significant differences between the two adhesives for all the parameters evaluated, irrespective of the recall (p>0.05). After 3 years, both adhesives presented an increase in the percentage of clinically acceptable marginal discoloration (C3S: 32.9% and GB: 26.8%) normally associated to clinically acceptable marginal defects (C3S: 35.8% and GB: 26.5%). Only 1 dentine margin of a GB restoration presented a severe marginal defect (1.2%) and 1 C3S restoration presented caries recurrence. The overall 3-year clinical success rate was 92.6% for C3S and 97.6% for GB (p=0.16). CONCLUSION:Both one-step self-etch adhesives presented an equally favourable clinical effectiveness at 3 years. CLINICAL SIGNIFICANCE:HEMA is a monomer frequently present in dental adhesives in order to increase their wettability and hydrophilicity. However, this monomer negatively influences hydrolytic stability and durability of the adhesive interface complex. In this 3-year clinical trial no significant difference in bonding effectiveness was noticed between a HEMA-rich and HEMA-free one-step adhesive.
OBJECTIVES:Polymerization shrinkage causes stress at the tooth-restoration interface. The magnitude of the stress depends upon several factors, such as the configuration factor (C-factor) of the cavity, the polymerization-conversion rate and filling technique. The aim of this study was to investigate the effect of curing time and filling method when high C-factor cavities were filled with low-shrinking composites. METHODS:Three low-shrinking (Filtek Silorane, 3M ESPE: FS; N'Durance, Septodont: N'D; Kalore, GC: Ka) and one conventional composite (Z100, 3M ESPE) were bonded into standardized occlusal Class-I cavities using either a two-step self-etch adhesive (Silorane System Adhesive, 3M ESPE: SSA) or a one-step self-etch adhesive (G-Bond, GC: GB). Five experimental groups were formed according to the employed adhesive/composite combination (SSA/FS, SSA/Z100, GB/N'D, GB/Ka, GB/Z100), and further divided into three subgroups conforming to curing time and filling technique (20 s/bulk; 80 s/bulk; 80 s/layered). For each subgroup, non-trimmed 1 mm×1 mm sticks were prepared from five teeth to measure the micro-tensile bond strength (μTBS) to cavity-bottom dentine. RESULTS:The two-step self-etch adhesive SSA generated higher bond strengths than the one-step self-etch adhesive GB, irrespective of the filling method. When GB was used, bulk filling with a low-shrinking composite revealed the highest bond strengths. For all composites, the layering method provided the highest bond strengths. SIGNIFICANCE:The two-step self-etch adhesive Silorane System Adhesive (3M ESPE) performed better than the one-step self-etch adhesive G-Bond (GC), regardless of the composite used. When the latter all-in-one adhesive was used, effects of shrinkage stress became more apparent.