Abstract Vijayalaxmi, Sasser, L. B., Morris, J. E., Wilson, B. W. and Anderson, L. E. Genotoxic Potential of 1.6 GHz Wireless Communication Signal: In Vivo Two-Year Bioassay. Radiat. Res. 159, 558–564 (2003). Timed-pregnant Fischer 344 rats (from nineteenth day of gestation) and their nursing offspring (until weaning) were exposed to a far-field 1.6 GHz Iridium wireless communication signal for 2 h/day, 7 days/week. Far-field whole-body exposures were conducted with a field intensity of 0.43 mW/cm2 and whole-body average specific absorption rate (SAR) of 0.036 to 0.077 W/kg (0.10 to 0.22 W/kg in the brain). This was followed by chronic, head-only exposures of male and female offspring to a near-field 1.6 GHz signal for 2 h/day, 5 days/week, over 2 years. Near-field exposures were conducted at an SAR of 0.16 or 1.6 W/kg in the brain. Concurrent sham-exposed and cage control rats were also included in the study. At the end of 2 years, all rats were necropsied. Bone marrow smears were examined for the extent of genotoxicity, assessed from the presence of micronuclei in polychromatic erythrocytes. The results indicated that the incidence of micronuclei/2000 polychromatic erythrocytes were not significantly different between 1.6 GHz-exposed, sham-exposed and cage control rats. The group mean frequencies were 5.6 ± 1.8 (130 rats exposed to 1.6 GHz at 0.16 W/kg SAR), 5.4 ± 1.5 (135 rats exposed to 1.6 GHz at 1.6 W/kg SAR), 5.6 ± 1.7 (119 sham-exposed rats), and 5.8 ± 1.8 (100 cage control rats). In contrast, positive control rats treated with mitomycin C exhibited significantly elevated incidence of micronuclei/2000 polychromatic erythrocytes in bone marrow cells; the mean frequency was 38.2 ± 7.0 (five rats). Thus there was no evidence for excess genotoxicity in rats that were chronically exposed to 1.6 GHz compared to sham-exposed and cage controls.
An animal model for large granular lymphocytic (LGL) leukemia in male Fischer 344 rats was utilized to determine whether magnetic field exposure can be shown to influence the progression of leukemia. We previously reported that exposure to continuous 60 Hz, 1 mT magnetic fields did not significantly alter the clinical progression of LGL leukemia in young male rats following injection of spleen cells from donor leukemic rats. Results presented here extend those studies with the following objectives: (a) to replicate the previous study of continuous 60 Hz magnetic field exposures, but using fewer LGL cells in the inoculum, and (b) to determine if intermittent 60 Hz magnetic fields can alter the clinical progression of leukemia. Rats were randomly assigned to four treatment groups (18/group) as follows: (1) 1 mT (10 G) continuous field, (2) 1 mT intermittent field (off/on at 3 min intervals), (3) ambient controls ( < 0.1 microT), and (4) positive control (5 Gy whole body irradiation from cobalt-60 four days prior to initiation of exposure). All rats were injected intraperitoneally with 2.2 x 10(6) fresh, viable LGL leukemic spleen cells at the beginning of the study. The fields were activated for 20 h per day, 7 days per week, and all exposure conditions were superimposed over the natural ambient magnetic field. The rats were weighed and palpated for splenomegaly weekly. Splenomegaly developed 9-11 weeks after transplantation of the leukemia cells. Hematological evaluations were performed at 6, 8, 10, 12, 14, and 16 weeks of exposure. Peripheral blood hemoglobin concentration, red blood cells, and packed cell volume declined, and total white blood cells and LGL cells increased dramatically in all treatment groups after onset of leukemia. Although the positive control group showed different body weight curves and developed signs of leukemia earlier than other groups, differences were not detected between exposure groups and ambient controls. Furthermore, there were no overall effects of magnetic fields on splenomegaly or survival in exposed animals. In addition, no significant and/or consistent differences were detected in hematological parameters between the magnetic field exposed and the ambient control groups.
A study of light, and mammary tumorigenesis was conducted in rats. One-hundred female Sprague–Dawley rats were divided by weight into two groups. One group was exposed to constant light (LL) from 26 days of age, and the second group was exposed to 8 h light and 16 h dark per day (LD). Both groups received an 8 mg dose of a chemical carcinogen, dimethylbenzanthracene (DMBA) at 52 days of age. At 13 weeks post-DMBA, there were significantly fewer mammary tumors in the LL group compared with the LD group. Constant light was clearly demonstrated to have a profound effect on mammary tissue development. Although virgin, the majority of the LL rats (29/50) had gross evidence of lactation at 141 days of age. None of the LD rats (0/50) showed evidence of milk production. These results suggest that constant light not only substantially accelerated mammary gland development, but pushed development of the tissue past the stage normally observed in virgin animals (to the lactation stage).
The purpose of this study was to determine if 60 Hz magnetic fields can alter the clinical progression of leukemia in an animal model. Large granular lymphocytic (LGL) leukemia cells from spleens of leukemic rats were transplanted into young male Fischer 344 rats, producing signs of leukemia in approximately 2–3 months. The animals were randomly assigned to 4 treatment groups (108/group) as follows: 1) 10 G (1.0 mT) linearly polarized 60 Hz magnetic fields, 2) sham exposed [null energized unit with residual 20 mG (2 μT) fields], 3) ambient controls [<1 mG (0.1 μT)], and 4) positive controls (a single 5 Gy whole body exposure to 60Co 4 days prior to initiation of exposure). All rats were injected intraperitoneally (ip) with 2.2 × 107 LGL leukemic cells at the initiation of exposure or sham exposure. The magnetic fields were activated for 20 h/day, 7 days/week, allowing time for animal care. The experimental fields were in addition to natural ambient magnetic fields. Eighteen rats from each treatment group were bled, killed, and evaluated at 5, 6, 7, 8, 9, and 11 weeks of exposure. Peripheral blood hematological endpoints, changes in spleen growth, and LGL cell infiltration into the spleen and liver were measured to evaluate the leukemia progression. No significant or consistent differences were detected between the magnetic field exposed groups and the ambient control group, although the clinical progress of leukemia was enhanced in the positive control animals. These data indicate that exposure to sinusoidal, linearly polarized 60 Hz, 10 G magnetic fields did not significantly alter the clinical progression of LGL leukemia. Furthermore, the data are in general agreement with previous results of a companion repeated-bleeding study in which animals were exposed for 18 weeks. Bioelectromagnetics 20:48–56, 1999. © 1999 Wiley-Liss, Inc.
It has been proposed that extremely low frequency magnetic fields may enhance tumorigenesis through a co-promotional mechanism. This hypothesis has been further tested using the two-stage model of mouse skin carcinogenesis, i.e. 12-O-tetradecanoylphorbol-13-acetate (TPA)-induced promotion of skin carcinogenesis in mice initiated by a single subcarcinogenic dose of 7,12-dimethylbenz[a]anthracene. Experimentation utilized three different doses of TPA within its dose-response range (0.85, 1.70 or 3.40 nmol) and examined the following early biomarkers of tumor promotion after 1, 2 and 5 weeks of promotion: increases in epidermal thickness and the labeling index of epidermal cells, induction of epidermal ornithine decarboxylase activity and down-regulation of epidermal protein kinase C activity, Mice exposed to a 60 Hz magnetic field having a flux density of 2 mT for 6 h/day for 5 days/week were compared with mice exposed to an ambient magnetic field. Within the sensitivity limits of the biomarker methodology and the exposure parameters employed, no consistent, statistically significant effects indicative of promotion or co-promotion by the magnetic field were demonstrated.
Experiments using the dwarf Siberian hamster Phodopus sungorus were carried out to determine possible neuroendocrine consequences of one-time and repeated exposures to 60 Hz magnetic fields (MF). Animals were maintained in either a short-light (SL, 8 h light:16 h dark) or long-light (LL, 16 h light:8 h dark) photoperiod. Acute (one-time, 15 min) exposure of male SL animals to a linearly polarized, horizontally oriented, 60 Hz MF (0.1 mT) gave rise to a statistically significant (P < .005) reduction in pineal melatonin content as determined 3 and 5 h after onset of darkness. In LL animals, acute exposure to 0.10 mT resulted in a significant decrease in pineal melatonin as measured 4 h after onset of darkness, whereas acute exposure to 50 μT showed no effect compared with sham exposure. In SL animals, an increase in norepinephrine was observed in the medial basal hypothalamus (including the suprachiasmatic nucleus) after acute exposure (P < .01). Daily MF exposure of SL animals to a combination of steady-state and on/off 60 Hz magnetic fields (intermittent exposure) at 0.1 mT for 1 h per day for 16 days was associated with a reduction in melatonin concentrations at 4 h after onset of darkness and an increase in blood prolactin concentrations (P < .05). Exposure of SL animals to a steady state 60 Hz MF for 3 h/day for 42 days resulted in a statistically significant reduction in body weight (ANOVA: P > .05), compared with sham-exposed SL animals. At 42 days, however, no significant changes in overnight melatonin or prolactin levels were detected. In both repeated exposure experiments, gonadal weights were lowest in the MF-exposed groups. This difference was statistically significant (P < .05) after 42 days of exposure. These data indicate that both one-time and repeated exposure to a 0.1 mT, 60 Hz MF can give rise to neuroendocrine responses in Phodopus. Bioelectromagnetics 20:224–232, 1999. © 1999 Wiley-Liss, Inc.
Associations between exposure to 60-Hz magnetic fields in residential and occupational environments and the incidence of leukemia and other cancers has been suggested by the results of a number of epidemiology studies. To address these potential associations, a study has been conducted to determine if 60-Hz magnetic fields can alter the clinical progression of leukemia. In the large granular lymphocytic (LGL) leukemia model, spleen cells from aged leukemic rats were transplanted into young, male Fischer 344 rats, producing leukemia in a relatively short period. A total of 72 animals were randomly assigned to four treatment groups (18/group) as follows: (1) 10 G; (2) sham exposed (null energized field) (approximately 20 mG); (3) ambient controls (<1 mG); and (4) positive controls (5 Gy whole body irradiation from Cobalt-60, 4 days before initiation of exposure). At the initiation of exposure or sham-exposure, all rats were injected (i.p.) with 2.2x10(7) fresh, viable, LGL leukemia cells. The magnetic fields were activated for 20 h per day, 7 days per week; all exposure conditions were superimposed over the natural ambient magnetic field. Eighteen rats from each treatment were bled at weeks 0, 2, 4, 5, 6, 7, 8 and 10 to monitor, in the same set of animals, the clinical progression of the LGL disease and survival of the animals. Peripheral blood hematological changes were monitored to evaluate the progression of the leukemia. In general, no significant or consistent differences were detected between the magnetic field exposed and the ambient field control groups, although some inconsistent and random differences were occasionally observed. These data indicate that the 10 G magnetic fields did not significantly alter the clinical progression of LGL leukemia in Fischer 344 rats.
A study was carried out to determine possible effects of 60‐Hz electromagnetic‐field exposure on pineal gland function in humans. Overnight excretion of urinary 6‐hydroxymelatonin sulfate (6‐OHMS), a stable urinary metabolite of the pineal hormone melatonin, was used to assess pineal gland function in 42 volunteers who used standard (conventional) or modified continuous polymer wire (CPW) electric blankets for approximately 8 weeks. Volunteers using conventional electric blankets showed no variations in 6‐OHMS excretion as either a group or individuals during the study period. Serving as their own controls, 7 of 28 volunteers using the CPW blankets showed statistically significant changes in their mean nighttime 6‐OHMS excretion. The CPW blankets switched on and off approximately twice as often when in service and produced magnetic fields that were 50% stronger than those from the conventional electric blankets. On the basis of these findings, we hypothesize that periodic exposure to pulsed DC or extremely low frequency electric or magnetic fields of sufficient intensity and duration can affect pineal gland function in certain individuals.