The characteristics of 22–40keV Kα x-ray sources are measured. These high-energy sources are produced by 100TW and petawatt high-intensity lasers and will be used to develop and implement workable radiography solutions to probe high-Z and dense materials for the high-energy density experiments. The measurements show that the Kα source size from a simple foil target is larger than 60μm, too large for most radiography applications. The total Kα yield is independent of target thicknesses, verifying that refluxing plays a major role in photon generation. Smaller radiating volumes emit brighter Kα radiation. One-dimensional radiography experiments using small-edge-on foils resolved 10μm features with high contrast. Experiments were performed to test a variety of small volume two-dimensional point sources such as cones, wires, and embedded wires, measured photon yields, and compared the measurements with predictions from hybrid-particle-in-cell simulations. In addition to high-energy, high-resolution backlighters, future experiments will also need imaging detectors and diagnostic tools that are workable in the high-energy range. An initial look at some of these detector issues is also presented.
We are developing a petawatt laser for use as a high-energy backlighter source in the 20-100 keV range on the National Ignition Facility (NIF). High-energy x-ray backlighters will be essential for radiographing high-energy-density experimental science (HEDES) targets, especially to probe implosions and high areal density planar samples. For these high energy backlighter imaging experiments, we are developing two types of detectors: a columnar grown CsI scintillator coupled to a 2 Kx2 K charge-coupled device camera, and a CdTe crystal with special application specific integrated circuit readout electronics in a 508x512 format array. We characterized these sensors using Cd-109 and Am-241 radioactive isotopes. In addition, we employed them to measure the Sm Kalpha source size generated by the short pulse laser, JanUSP, at Lawrence Livermore National Laboratory. The CsI camera performed well, allowing a measurement of the Sm Kalpha source size. Calibration of this camera has shown that it has low noise and good resolution. The new CdTe camera performed well, however the noise level was too high for single photon counting. Some modifications to the camera will also be necessary in order to meet the needs of future hard x-ray experiments. Both cameras showed considerable promise as diagnostic tools for future high-energy x-ray backlighters for NIF HEDES experiments. This article will present the results of our characterizations of these detectors, and initial results from the JanUSP experiments. (C) 2004 American Institute of Physics.
We are developing a petawatt laser for use as a high energy backlighter source in the 20{approx} 100 keV range. High energy x-ray backlighters will be essential for radiographing High-Energy- Density Experimental Science (HEDES) targets for NIF projects especially to probe implosions and high areal density planar samples. For these experiments we are employing two types of detectors: a columnar grown CsI scintillator coupled to a 2K x 2K CCD camera and a CdTe crystal with a special ASIC readout electronics in a 508 x 512 format array. We have characterized these sensors using radioactive sources. In addition, we utilized them to measure the Sm K{alpha} source size generated by the short pulse laser, JanUSP, at LLNL. This paper will present the results of our characterizations of these detectors.