Zwitterionic near infrared fluorescent agents were developed for non-invasive real-time transcutaneous assessment of kidney function.
Transcutaneous measurement of the glomerular filtration rate ((t)GFR) is now frequently used in animal studies. (t)GFR allows consecutive measurements on the same animal, including multiple measurements on a daily basis, because no blood sampling is required. Here we derive and validate a novel kinetic model for the description of transcutaneously measured FITC-Sinistrin excretion kinetics. In contrast to standard 1- to 3-compartment models, our model covers the complete kinetic, including injection and distribution of the tracer in the plasma compartment. Because the model describes the complete progression of the measurement, it allows further refinement by correcting for baseline shifts observed occasionally during measurement. Possible reasons for shifts in the background signal include photo bleaching of the skin, autofluorescence, changes of physiological state of the animals during the measurements, or effects arising from the attachment of the measurement device. Using the new 3-compartment kinetic model with modulated baseline ((t)GFR(3cp.b.m)), (t)GFR measurements in rats can reach comparable precision as those from GFR measurements assessed using a gold standard technique based on constant infusion of a tracer. Moreover, the variability of simultaneous (parallel) measurements, as well as repeated (t)GFR measurements in the same animals, showed higher precision when (t)GFR(3cp.b.m) was compared with the 1 compartment (t)GFR(1cp) model.
Evaluation of renal function is crucial for a number of clinical situations. Here, we reported a novel exogenous fluorescent marker (FITC-HPβCD) to real-time assess renal function by using a transcutaneous fluorescent detection technique. FITC-HPβCD was designed based on the principle of renal clearance of designed drugs. It displays favorable fluorescent properties, high hydrophilicity, low plasma protein binding, and high stability in porcine liver esterase as well as in plasma and nontoxicity. More importantly, FITC-HPβCD can be efficiently and rapidly filtered by glomerulus and completely excreted into urine without proximal tubular reabsorption or secretion in rat models. Additionally, the marker was well-tolerated, with nearly 100% urinary recovery of the given doses, and no metabolism were found. Relying on this novel kidney function marker and transcutaneous devices, we demonstrate a rapid, robust, and convenient approach for real-time assessing renal function without the need of time-consuming blood and urine sample preparation. Our work provides a promising tool for noninvasive real-time monitoring of renal function in vivo.
Glomerular filtration rate (GFR) is considered the best parameter for the assessment of renal function, being usually determined on the basis of urine or plasma clearance of exogenous renal markers. The common methodology is invasive, time consuming and cumbersome, with multiple blood and/or urine sampling and following laboratory assays required. The method detailed here allows to transcutaneously determine the renal function in awake animals, in a non-invasive and efficient manner by using an electronic device which detects the fluorescence emitted through the skin from the renal marker FITC-Sinistrin. A crucial target has been to improve the fixation of the device, which is dependent on the skin structure. For validation, the technique has been compared with the classical clearance method, and its robustness has been demonstrated in healthy and diseased murine models. Moreover, the method allows sequential measurements in the same individual. Thus progression and recovery of renal failure can be followed. Therefore, its future application in humans would allow an accurate and appropriate prediction and monitoring of patients with established kidney disease over time. Furthermore, it will be possible to observe those patients under other pathological conditions with associated risk of developing renal problems.
Measuring renal function in laboratory animals using blood and/or urine sampling is not only labor-intensive but puts also a strain on the animal. Several approaches for fluorescence based transcutaneous measurement of the glomerular filtration rate (GFR) in laboratory animals have been developed. They allow the measurement of GFR based on the elimination kinetics of fluorescent exogenous markers. None of the studies dealt with the reproducibility of the measurements in the same animals. Therefore, the reproducibility of a transcutaneous GFR assessment method was investigated using the fluorescent renal marker FITC-Sinistrin in conscious mice in the present study. We performed two transcutaneous GFR measurements within three days in five groups of mice (Balb/c, C57BL/6, SV129, NMRI at 3-4 months of age, and a group of 24 months old C57BL/6). Data were evaluated regarding day-to-day reproducibility as well as intra- and inter-strain variability of GFR and the impact of age on these parameters. No significant differences between the two subsequent GFR measurements were detected. Fastest elimination for FITC-Sinistrin was detected in Balb/c with significant differences to C57BL/6 and SV129 mice. GFR decreased significantly with age in C57BL/6 mice. Evaluation of GFR in cohorts of young and old C57BL/6 mice from the same supplier showed high consistency of GFR values between groups. Our study shows that the investigated technique is a highly reproducible and reliable method for repeated GFR measurements in conscious mice. This gentle method is easily used even in old mice and can be used to monitor the age-related decline in GFR.
Constant infusion clearance techniques using exogenous renal markers are considered the gold standard for assessing the glomerular filtration rate. Here we describe a constant infusion clearance method in rats allowing the real-time monitoring of steady-state conditions using an automated closed-loop approach based on the transcutaneous measurement of the renal marker FITC-sinistrin. In order to optimize parameters to reach steady-state conditions as fast as possible, a Matlab-based simulation tool was established. Based on this, a real-time feedback-regulated approach for constant infusion clearance monitoring was developed. This was validated by determining hourly FITC-sinistrin plasma concentrations and the glomerular filtration rate in healthy and unilaterally nephrectomized rats. The transcutaneously assessed FITC-sinistrin fluorescence signal was found to reflect the plasma concentration. Our method allows the precise determination of the onset of steady-state marker concentration. Moreover, the steady state can be monitored and controlled in real time for several hours. This procedure is simple to perform since no urine samples and only one blood sample are required. Thus, we developed a real-time feedback-based system for optimal regulation and monitoring of a constant infusion clearance technique. Kidney International (2012) 82, 314-320; doi:10.1038/ki.2012.117; published online 18 April 2012
Determination of glomerular filtration rate (GFR) in conscious mice is cumbersome for the experimenter and stressful for the animals. Here we report on a simple new technique allowing the transcutaneous measurement of GFR in conscious mice. This approach extends our previously developed technique for rats to mice. The technique relies on a miniaturized device equipped with an internal memory that permits the transcutaneous measurement of the elimination kinetics of the fluorescent renal marker FITC-sinistrin. This device is described and validated compared with FITC-sinistrin plasma clearance in healthy, unilaterally nephrectomized and pcy mice. In summary, we describe a technique allowing the measurement of renal function in freely moving mice independent of blood or urine sampling as well as of laboratory assays.
Determination of the urinary or plasma clearance of exogenous renal markers, such as inulin or iohexol, is considered to be the gold standard for glomerular filtration rate (GFR) measurement. Here, we describe a technique allowing determination of renal function based on transcutaneously measured elimination kinetics of fluorescein isothiocyanate (FITC)-sinistrin, the FITC-labeled active pharmaceutical ingredient of a commercially available marker of GFR. A low cost device transcutaneously excites FITC-sinistrin at 480 nm and detects the emitted light through the skin at 520nm. A radio-frequency transmission allows remote monitoring and real-time analysis of FITC-sinistrin excretion as a marker of renal function. Due to miniaturization, the whole device fits on the back of freely moving rats, and requires neither blood sampling nor laboratory assays. As proof of principle, comparative measurements of transcutaneous and plasma elimination kinetics of FITC-sinistrin were compared in freely moving healthy rats, rats showing reduced kidney function due to unilateral nephrectomy and PKD/Mhm rats with cystic kidney disease. Results show highly comparable elimination half-lives and GFR values in all animal groups. Bland-Altman analysis of enzymatically compared with transcutaneously measured GFR found a mean difference (bias) of 0.01 and a -0.30 to 0.33 ml/min per 100 g body weight with 95% limit of agreement. Thus, with this device, renal function can be reliably measured in freely moving rats eliminating the need for and influence of anesthesia on renal function. Kidney International (2011) 79, 1254-1258; doi:10.1038/ki.2011.31; published online 2 March 2011
BACKGROUND Inulin/sinistrin (I/S) clearance is a gold standard for an accurate assessment of glomerular filtration rate (GFR). Here we describe and validate an approach for a transcutaneous determination of GFR by using fluorescein-isothiocyanate-labelled sinistrin (FITC-S) in rats. METHODS Using a small animal imager, fluorescence is measured over the depilated ear of a rat after the injection of FITC-S. The decay curve of fluorescence is used for the calculation of half-life and GFR. The thus obtained transcutaneous data were validated by simultaneously performed enzymatic and fluorometric measurements in plasma of both FITC-S and sinistrin. RESULTS The results of enzymatic sinistrin determination versus transcutaneous half-life of FITC-S or plasma fluorescence correlated well with each other (R(2) > 0.90). Furthermore, Bland-Altman analyses proved a good degree of agreement of the three methods used. The measurements performed in healthy animals as well as different models of renal failure demonstrate its appropriateness in a wide range of renal function. CONCLUSIONS The transcutaneous method described offers a precise assessment of GFR in small animals. As neither blood and/or urine sampling nor time-consuming lab work is required, GFR can be determined immediately after the clearance procedure is finished. This method, therefore, simplifies and fastens GFR determinations in small lab animals compared to conventional bolus clearance techniques based on blood sampling. A low-cost device for the measurement of transcutaneous fluorescence intensity over time is under construction.
Determining true glomerular filtration rate (GFR) using an exogenous marker is time-consuming and cumbersome. Therefore, creatinine-based estimates of GFR are used. Recent papers using new population-specific/local parameters in their prediction equations, standardizing creatinine determination or adding other endogenous surrogate markers of GFR, like cystatin C, could demonstrate an improvement of bias inherent in the results of the prediction equations. Precision, however, is still poor. Currently, we have to accept a precision (as defined in the so-called Bland-Altman plot) of ±20% in adults and ±30–40% in children. This problem of poor precision/uncertainty is especially bothering in the higher, near normal GFR range. Caution should be exercised when applying prediction equations in individuals in need of an accurate GFR determination. In that case, a real clearance procedure has to be performed. In the long run, the true clearance procedure should be simplified using new exogenous GFR markers and developing new devices, allowing GFR measurements to be performed, for example, transcutaneously. Such a procedure would be more acceptable for both patients and physicians.