In vascular interventional radiology, procedures generally start with the Seldinger technique to access the vasculature, using a needle through which a guidewire is inserted, followed by navigation of catheters within the vessels. Visual and tactile skills are learnt in a patient apprenticeship which is expensive and risky for patients. We propose a training alternative through a new virtual simulator supporting the Seldinger technique: ImaGiNe (imaging guided interventional needle) Seldinger. It is composed of two workstations: (1) a simulated pulse is palpated, in an immersive environment, to guide needle puncture and (2) two haptic devices provide a novel interface where a needle can direct a guidewire and catheter within the vessel lumen, using virtual fluoroscopy. Different complexities are provided by 28 real patient datasets. The feel of the simulation is enhanced by replicating, with the haptics, real force and flexibility measurements. A preliminary validation study has demonstrated training effectiveness for skills transfer.
Computer-based simulation for interventional radiology training has attracted increasing attention in recent years because of its potential to train remotely from patients and to provide objective assessment of proficiency. Yet developing a high fidelity simulator with realistic tactile feedback requires accurate knowledge of forces exerted on medical devices during interventional radiology procedures. This paper presents the development and validation of a force sensor for the measurement of axial forces generated during needle, and combined cannula/trocar, puncture procedures in patients. In order to assess the performance of this sensor, in vitro measurements were obtained using needle penetration of porcine liver, kidney and muscle. The results were compared with forces measured by means of a tensile tester. Calibration results showed that the force sensor has high sensitivity and linearity. Comparison of the force profiles obtained from the sensor and the tensile tester shows that good agreement was achieved in the in vitro studies for all the tissues tested. Preliminary clinical force measurements during arterial puncture and liver biopsy procedures have been performed in patients. An example of force recording for each procedure type is presented.
Recent years have seen a significant increase in the use of Interventional Radiology (IR) as an alternative to open surgery. A large number of IR procedures commences with needle puncture of a vessel to insert guidewires and catheters: these clinical skills are acquired by all radiologists during training on patients, associated with some discomfort and occasionally, complications. While some visual skills can be acquired using models such as the ones used in surgery, these have limitations for I R which relies heavily on a sense of touch. Both patients and trainees would benefit from a virtual environment (VE) conveying touch sensation to realistically mimic procedures. The authors are developing a high fidelity VE providing a validated alternative to the traditional apprenticeship model used for teaching the core skills. The current version of the CRaIVE simulator combines home made software, haptic devices and commercial equipments.