Articular cartilage of weight-bearing joints restores its thickness after loading through viscoelastic recovery. Creep-recovery is a key parameter for assessing cartilage biomechanical properties and is relevant for osteoarthritis (OA) diagnosis and cartilage replacement development. This study aimed to evaluate creep-recovery in human osteoarthritic cartilage. Full-thickness osteochondral explants (n = 34) were obtained from tibial plateaus of 14 patients undergoing total knee replacement. Samples were graded histologically as normal (n = 6), mild (n = 18), moderate (n = 6), and severe OA (n = 4). Biomechanical testing was performed with a high-dynamic closed-loop indentation system using a porous indenter. Five creep-recovery cycles were applied under controlled load (0.01–0.196N); the third cycle was analyzed for creep, creep rate, recovery, recovery rate and stiffness. Normal and mild OA cartilage showed notably less creep strain than moderate OA (11.13 ± 3.84
Quantitative analysis of acetabular bone loss in hip revision surgery remains limited. This hinders evidence-based implant selection and the development of standardised defect models. We present a computational workflow to reconstruct patient-specific revision cases as three-dimensional (3D) defect volume models to derive intersections and multi-sphere models. A total of 47 acetabular revision cases (Paprosky IIA-IIIB) were processed retrospectively. The acetabular defect surface mesh was isolated using curvature-guided manual refinement (mean boundary error: 2.62 +/- 1.69 mm), followed by distortion-free scaling and weighted alignment to a statistical shape model (SSM) of the pelvis. Two strategies were implemented to define the defect volumes: a fast Alpha Method and a high-fidelity Hybrid Model, which supplements the defect model with interior points of the reference pelvis. Threshold-based intersections, spatial defect distribution, and multi-sphere approximations (up to 10 spheres) were generated and benchmarked. The Hybrid Models preserved 77.26 +/- 21.55 % of the original acetabular defect vertices (alpha radius 6.23 +/- 4.55 ), compared to 34.04 +/- 20.26 % for the Alpha Method (alpha radius 32.53 +/- 9.97 ). The intersection analyses revealed a relevant, continuous acetabular margin, which Alpha Method failed to detect. The representative multi-sphere defect models achieved a mean surface error of less than 5 mm. This workflow creates representative 3D volume models of acetabular defects and compact multi-sphere models using standard computed tomography (CT) data. It provides a reproducible, quantitative framework for the objective classification and analysis of defects. It can also support implant planning and provide a standardised defect model for use in experimental or finite element studies.
SummaryFemoral fractures are often considered lethal for adult horses because femur osteosynthesis is still a surgical challenge. For equine femur osteosynthesis, primary stability is essential, but the detailed physiological forces occurring in the hindlimb are largely unknown. The objective of this study was to create a numerical testing environment to evaluate equine femur osteosynthesis based on physiological conditions. The study was designed as a finite element analysis (FEA) of the femur using a musculoskeletal model of the loading situation in stance. Relevant forces were determined in the musculoskeletal model via optimization. The treatment of four different fracture types with an intramedullary nail was investigated in FEA with loading conditions derived from the model. The analyzed diaphyseal fracture types were a transverse (TR) fracture, two oblique fractures in different orientations (OB-ML: medial-lateral and OB-AP: anterior-posterior) and a ”gap” fracture (GAP) without contact between the fragments. For the native femur, the most relevant areas of increased stress were located distally to the femoral head and proximally to the caudal side of the condyles. For all fracture types, the highest stresses in the implant material were present in the fracture-adjacent screws. Maximum compressive (-348 MPa) and tensile stress (197 MPa) were found for the GAP fracture, but material strength was not exceeded. The mathematical model was able to predict a load distribution in the femur of the standing horse and was used to assess the performance of internal fixation devices via FEA. The analyzed intramedullary nail and screws showed sufficient stability for all fracture types.
In tendon transfer surgeries sufficient stability of the tenorrhaphy is essential. In addition to the choice of a suitable technique, adequate overlap of donor and recipient tendons must be ensured. The aim of this study was to investigate the tensile strength with regard to tendon overlap of a recently published tenorrhaphy, termed Woven-Fridén (WF) tenorrhaphy, which displayed higher tensile strength and lower bulk when compared to the established Pulvertaft technique. For this purpose, WF tenorrhaphies with 1.5 cm, 2 cm, and 3 cm tendon overlap were performed and subsequently tested for different biomechanical properties by tensile testing. Among others, the parameters of ultimate load and stiffness were collected. Native tendons served as controls. A formula was derived to quantify the relation between tendon overlap and ultimate load. We observed that sufficient tensile strength (mean ultimate load of 217 N) is already given with a 2 cm tendon overlap. In addition, with more than 3 cm overlap length only little additional tensile strength is to be expected as the calculated ultimate load of 4 cm overlap (397 N) is approaching the plateau of the maximal ultimate load of 435 N (native tendons).
This study aimed to develop and evaluate a costeffective Inertial Measurement Unit (IMU) system for gait analysis, comparing its performance with the Vicon system and the VideoPose3D algorithm. The system comprises five calibrated sensors and a mobile app to measure lower body orientation during gait and stair climbing. Eight healthy participants were involved in the experiment, each performing ten repetitions to analyze hip and knee flexion angles. The IMU system demonstrated significantly lower mean square error than deep learning-based approaches and comparable results to the Vicon system, indicating its potential for clinical and research applications.
Wound healing can be delayed if the biomechanical stability of the wound closure is inadequate. Therefore, it is necessary to investigate different suturing techniques for their biomechanical stability. In this study, suturing techniques suitable for the forehead area were investigated. For this application, a special test setup was developed to simulate the curvature of the forehead and the corresponding physiological configuration. The average forehead curvature is 62.24 ± 4.11 mm in radius. To simulate this curvature, the skin specimens are subjected to tensile stress over the spherical surface using a standard uniaxial testing machine. For the evaluation, an automated evaluation tool for MATLAB was also developed. Three different suturing techniques (Straight, Lazy-S, Zigzag) were investigated and tested for their biomechanical stability. Of the three suturing techniques, the Zigzag suture proved to be the most stable with the highest stiffness of 44.23 ± 8.18 % and the highest final failure of 32.60 ± 4.95 % (relative to the control sample without incision). The study has shown that the test setup can be used to investigate different forehead suture techniques.
Here we present the GyroTrainer, a bespoke mechatronic balance board system designed to trigger activation of the back muscles while the user engages in a balance-challenging game. The GyroTrainer uses admittance control coupled with an iterative learning approach so as to tailor the admittance control parameters, i.e. difficulty level, according to the user's skill. Our experimental evaluation demonstrated that an individualized admittance control stiffness could be identified for each user, which corresponds with a desired level of difficulty and increased back muscle activity. A first game implementation demonstrates the feasibility of utilizing the GyroTrainer system and the individually identified admittance control stiffness for gamification of back muscle training.
Ewing sarcomas are malignant neoplasm entities typically found in children and adolescents. Early detection is crucial for therapy and prognosis. Due to the low incidence the general experience as well as according data is limited. Novel support tools for diagnosis, such as deep learning models for image interpretation, are required. While acquiring sufficient data is a common obstacle in medicine, several techniques to tackle small data sets have emerged. The general necessity of large data sets in addition to a rare disease lead to the question whether transfer learning can solve the issue of limited data and subsequently support tasks such as distinguishing Ewing sarcoma from its main differential diagnosis (acute osteomyelitis) in paediatric radiographs. 42,608 unstructured radiographs from our musculoskeletal tumour centre were retrieved from the PACS. The images were clustered with a DeepCluster, a self-supervised algorithm. 1000 clusters were used for the upstream task (pretraining). Following, the pretrained classification network was applied for the downstream task of differentiating Ewing sarcoma and acute osteomyelitis. An untrained network achieved an accuracy of 81.5%/54.2%, while an ImageNet-pretrained network resulted in 89.6%/70.8% for validation and testing, respectively. Our transfer learning approach surpassed the best result by 4.4%/17.3% percentage points. Transfer learning demonstrated to be a powerful technique to support image interpretation tasks. Even for small data sets, the impact can be significant. However, transfer learning is not a final solution to small data sets. To achieve clinically relevant results, a structured and systematic data acquisition is of paramount importance.
For the development of new types of hip implants for acetabulum revision, it is beneficial to analyse the acetabular defects of the indication group in advance. In order to be able to specially compare the bone defects with each other, a normalisation and accompanying scaling of the pelvis is necessary. Uniform scaling is required so that the bone structures are not distorted. In the following study, three scaling methods based on the minimal bounding box and sphere principle are compared with a method using 14 landmarks on the pelvis.The landmark method is applied to determine the true scaling factor. For the comparison of the different methods, 40 female pelvic models with an acetabular defect are analysed. In the comparison of the scaling methods, the method using minimal bounding spheres shows the least deviation from the landmark method (mean difference 3.30 ± 2.17 %). Due to the fact that no preprocessing (definition of the landmarks) is required and the fast implementation of the algorithm, the minimal bounding sphere is to be preferred to the landmark method for a fast size estimation.
Dislocated tibial avulsions of the posterior cruciate ligament (PCL) require surgical intervention. Several arthroscopic strategies are options to fix the fragment and restore posterior laxity, including two types of suspension button devices: adjustable (self-locking) and rigid knotted systems. Our hypothesis was that a rigid knotted button construct has superior biomechanical properties regarding laxity restoration compared with an adjustable system. Both techniques were compared with standard screw fixation and the native PCL. Sixty porcine knees were dissected. The constructs were tested for elongation, stiffness, yield force, load to failure force, and failure mode in a material testing machine. Group N (native, intact PCL) was used as a control group. In group DB (Dogbone™), TR (Tightrope™), and S (screw), a standardized block osteotomy with the osteotomized fragment attached to the PCL was set. The DB and TR groups simulated using a suspension button system with either a rigid knotted (DB) or adjustable system (TR). These groups were compared to a screw technique (S) simulating antegrade screw fixation from posterior. Comparing the different techniques (DB, TR, S), no significant elongation was detected; all techniques achieved a sufficient posterior laxity restoration. Significant elongation in the DB and TR group was detected compared with the native PCL (N). In contrast, screw fixation did not lead to significant elongation. The stiffness, yield load, and load to failure force did not differ significantly between the techniques. None of the techniques reached the same level of yield load and load to failure force as the intact state. Arthroscopic suspension button techniques sufficiently restore the posterior laxity and gain a comparable construct strength as an open antegrade screw fixation.
Introduction: Osteosynthesis of the equine femur is still a challenge for veterinary medicine. Even though intramedullary fracture fixation is possible nowadays, the varying geometry of the medullary cavity along the bone axis is a critical factor. Limited contact area between implant and bone can cause insufficient primary stability. In this study, it was investigated whether the osteosynthesis stability can be improved with a form-adaptive reinforcement for the diaphyseal part of the proximal fragment. Material and Methods: Eight equine femora were fitted with intramedullary nail osteosynthesis and analyzed by 4-point bending. Virtual position planning of the ex-vivo implantation using CT-data increased comparability. For five femora the proximal fragment was reinforced with a flexible polymer mixture. Longterm stability was tested via cyclic loading. Bending stiffness and its development due to cyclic loading was evaluated before and after reinforcement procedure. Finally, load-to-failure was tested in the same setup. Results and Discussion: The application of the polymer reinforcement increased the maximum torque in the load-tofailure measurement by 26%. Bending stiffness was not affected in the measured loading range by the reinforcement. Cyclic loading increased bending stiffness for a conditioned state but showed to be reversible for the most part. Conclusion: The fracture adjacent reinforcement showed to be beneficial to the osteosynthesis stability, but further investigation is necessary for surgical application.
This paper presents the application of an adaptive exoskeleton for finger rehabilitation. The system consists of a force-controlled exoskeleton of the finger and wireless coupling to a mobile application for the rehabilitation of complex regional pain syndrome (CRPS) patients. The exoskeleton has sensors for motion detection and force control as well as a wireless communication module. The proposed mobile application allows to interactively control the exoskeleton, store collected patient-specific data, and motivate the patient for therapy by means of gamification. The exoskeleton was applied to three CRPS patients over a period of six weeks. We present the design of the exoskeleton, the mobile application with its game content, and the results of the performed preliminary patient study. The exoskeleton system showed good applicability; recorded data can be used for objective therapy evaluation.
BACKGROUND/AIM:Increasing economic pressure in modern healthcare necessitates an increase in efficiency in total knee arthroplasty (TKA) while maintaining high-quality outcomes. Removal of debris using pulsatile lavage (PL) during cement polymerization may considerably reduce the operative duration. However, water can penetrate the interface, resulting in impaired implant fixation. The aim of the present study was to investigate the impact of early-onset PL during bone cement polymerization on implant fixation and operative duration.MATERIALS AND METHODS:Cemented implantation of tibial trays was performed in 20 fresh-frozen human tibiae from 10 donors in a matched-pair study design in two groups: 1) PL during cement polymerization; and 2) PL after completion of the polymerization process. The cement penetration depth was analysed by computed tomography (CT), and the pull-out force was measured to evaluate primary implant fixation. The duration of the procedure was recorded for both groups.RESULTS:Comparable pull-out forces were observed in the experimental (2,213 N) and control groups (2,350 N; p=0.68). The mean depth of cement penetration was similar in both groups. PL during cement polymerization could decrease the operative duration by 10 min.CONCLUSION:The application of PL during cement polymerization could significantly reduce operative duration and had no adverse effect on the mechanical fixation of the tibial component.
In this study, top ology optimized, patient specific os teosynthesis plates (TOPOS-implants) are evaluated for the mandibular reconstruction using fibula segments. These shape optimized implants are compared to a standard treatment with miniplates (thickness: 1.0 mm, titanium grade 4) in biomechanical testing using human cadaveric specimen. Mandible and fibula of 21 body donors were used. Geometrical models were created based on automated segmentation of CT-scans of all specimens. All reconstructions, including cutting guides for osteotomy as well as TOPOS-implants, were planned using a custom-made software tool. The TOPOS-implants were produced by electron beam melting (thickness: 1.0 mm, titanium grade 5). The fibula-reconstructed mandibles were tested in static and dynamic testing in a multi-axial test system, which can adapt to the donor anatomy and apply side-specific loads. Static testing was used to confirm mechanical similarity between the reconstruction groups. Force-controlled dynamic testing was performed with a sinusoidal loading between 60 and 240 N (reconstructed side: 30% reduction to consider resected muscles) at 5 Hz for up to 5 · 10 5 cycles. There was a significant difference between the groups for dynamic testing: All TOPOS-implants stayed intact during all cycles, while miniplate failure occurred after 26.4% of the planned loading (1.32 · 10 5 ± 1.46 · 10 5 cycles). Bone fracture occurred in both groups (miniplates: n = 3, TOPOS-implants: n = 2). A correlation between bone failure and cortical bone thickness in mandible angle as well as the number of bicortical screws used was demonstrated. For both groups no screw failure was detected. In conclusion, the topology optimized, patient specific implants showed superior fatigue properties compared to miniplates in mandibular reconstruction. Additionally, the patient specific shape comes with intrinsic guiding properties to support the reconstruction process during surgery. This demonstrates that the combination of additive manufacturing and topology optimization can be beneficial for future maxillofacial surgery.
Recent studies conclude that a new technique for tendon transfers, the side-to-side tenorrhaphy by Friden (FR) provides higher biomechanical stability than the established standard first described by Pulvertaft (PT). The aim of this study was to optimize side-to-side tenorrhaphies. We compared PT and FR tenorrhaphies as well as a potential improvement, termed Woven-Friden tenorrhaphy (WF), with regard to biomechanical stability. Our results demonstrate superior biomechanical stability and lower bulk of FR and, in particular, WF over PT tenorrhaphies. The WF and FR technnique therefore seem to be a notable alternative to the established standard tenorrhaphy as they display lower bulk and higher stability, permitting successful immediate active mobilization after surgery.
Abstract Bioreactors with a controlled physiological environment are being developed to study various cell processes. The influences of mechanostimulation on bone cell cultures can be investigated using a compression bioreactor. The developed bioreactor system applies a cyclic compression force to the specimen via an eccentrically mounted push rod. The compression force is monitored by a force sensor to detect changes in the material properties of the specimen. Depending on the piston setting, a stroke of 0.28 - 2.50 mm can be applied to the specimen. The bioreactor system was tested with a trial run of 18 days. A sample was continuously stimulated with a loading frequency of 2 Hz and a stroke of 1.50 mm. The sterility in the cell chamber as well as the functionality of the realised bioreactor stimulation system could be successfully confirmed
Purpose Arthroscopic partial meniscectomy of medial meniscus tears and varus alignment are considered independent risk factors for increased medial compartment load, thus contributing to the development of medial osteoarthritis. The purpose of this biomechanical study was to investigate the effect of lower limb alignment on contact pressure and contact area in the knee joint following sequential medial meniscus resection. It was hypothesized that a meniscal resection of 50% would lead to a significant overload of the medial compartment in varus alignment. Methods Eight fresh-frozen human cadaveric knees were axially loaded with a 750 N compressive force in full extension with the mechanical axis rotated to intersect the tibia plateau at 30%, 40%, 50%, 60% and 70% of its width. Tibiofemoral mean contact pressure (MCP), peak contact pressure (PCP), and contact area (CA) of the medial and lateral compartment were measured separately using pressure-sensitive films (K-Scan 4000, Tekscan) in four different meniscal conditions, respectively, intact, 50% resection, 75% resection, and total meniscectomy. Results Medial MCP was significantly increased when comparing the intact meniscus to each meniscal resection in all tested alignments (p < 0.05). Following meniscal resection of 50%, MCP was significantly higher with greater varus alignment compared to valgus alignment (p < 0.05). Similarly, medial PCP was higher at varus alignment compared to valgus alignment (p < 0.05). Further resection to 75% and 100% of the meniscus resulted in a significantly higher medial PCP at 30% of tibia plateau width compared to all other alignments (p < 0.05). Medial CA of the intact meniscus decreased significantly after 50%, 75% and 100% meniscal resection in all alignments (p < 0.05). Lateral joint pressure was not significantly increased by greater valgus alignment. Conclusion Lower limb alignment and the extent of medial meniscal resection significantly affect tibiofemoral contact pressure. Combined varus alignment and medial meniscal resection increased MCP and PCP within the medial compartment, whereas valgus alignment prevented medial overload. As a clinical consequence, lower limb alignment should be considered in the treatment of patients undergoing arthroscopic partial meniscectomy with concomitant varus alignment. In patients presenting with ongoing medial joint tenderness and effusion, realignment osteotomy can be a surgical technique to unload the medial compartment.
Aims and Objectives: Tibial posterior cruciate ligament (PCL) avulsion fractures require surgical fixation in order to provide primary stability and adequate bone healing. Small fragments are common and comprise the risk to fracturing during screw fixation. Therefore, a suture-bridge configuration was developed to fixate small and multifragment fractures without the need of fragment drilling. The purpose of this study was to analyze the biomechanical properties of the suture-bridge technique compared to a well-established transtibial cortical suspension technique concerning cyclic elongation, stiffness and ultimate failure load. It was hypothesized that the suture bridge technique shows lower cyclic elongation and higher load to failure force compared to a cortical suspension button fixation. Materials and Methods: Nine fresh-frozen human cadaveric knees were biomechanically tested using an industrial testing machine (Zwick/Roell Amsler HC 10, Ulm). A standardized bony avulsion fracture (15 x 10 x 4 mm) of the tibial PCL insertion was generated. Two different techniques were used for fixation: A) 4x suture-bridge configuration (3 SwiveLock anchors, FiberTape, Arthrex Inc.) and B) 5x transtibial cortical suspension button fixation (FiberTape, Arthrex Inc). Cyclic loading was applied in 90° of flexion 500 times (10 to 100 N) to determine elongation, initial stiffness and load to failure. Students t-test for unpaired samples were used to calculate the difference of means (SPSS statistics software version 21). Statistical significance was set at a p value of < 0.05. Results: Suture-bridge technique resulted in a significant lower elongation (4.5 ± 2.9 mm) than transtibial cortical suspension button technique (11.9 ± 3.1 mm, p<0.01). Load of failure testing exhibited 319.8 ± 79.7 N in Group A and 232.6 ± 108.2 N in Group B (p=0.21). The initial stiffness at the beginning of cyclic loading was 45.0 ± 7.7 N/mm in Group A und 40.9 ± 10.0 N/mm in Group B (p=0.52). Conclusion: The novel PCL suture-bridge technique provides a significant lower construct elongation during cyclic loading and a trend towards higher load to failure in comparison to cortical suspension button fixation. As a clinical consequence, suture-bridge technique should be considered to fix small PCL avulsion fractures at the tibial insertion site.
In this article, two new compliant control architectures are introduced that utilize null space solutions to decouple force and position control. They are capable to interact with uncertain surfaces and environments with varying materials and require fewer parameters to be tuned than the common architectures – hybrid or impedance control. The general concept behind these approaches allows to consider manipulators with six degrees of freedom as redundant by creating a virtual redundancy with a reduced work space. It will be demonstrated that the introduced approaches are superior regarding orthogonal separation of the Cartesian degrees of freedom and avoid inner singularities. To demonstrate their performance, the controllers are tested on a standard industrial robot (Stäubli, RX90B, six degrees of freedom) that actuates two different biomechanically inspired models of the human knee joint.
Assessment of medial meniscus extrusion (MME) has become increasingly popular in clinical practice to evaluate the dynamic meniscus function and diagnose meniscus pathologies. The purpose of this biomechanical study was to investigate the correlation between MME and the changes in joint contact pressure in varus and valgus alignment. It was hypothesized that varus alignment would result in significantly higher MME along with a higher joint contact pressure in the medial compartment. Eight fresh-frozen human cadaveric knees were axially loaded, with a 750 N compressive load, in full extension with the mechanical axis shifted to intersect the tibial plateau at 30% and 40% (varus), 50% (neutral), 60% and 70% (valgus) of its width (TPW). Tibiofemoral peak contact pressure (PCP), mean contact pressure (MCP) and contact area (CA) were determined using pressure-sensitive films. MME was obtained via ultrasound at maximum load. MME was significantly increased from valgus (1.32 ± 0.22 mm) to varus alignment (3.16 ± 0.24 mm; p < 0.001). Peak contact pressure at 30% TPW varus alignment was significantly higher compared to 60% TPW valgus (p = 0.018) and 70% TPW valgus (p < 0.01). MME significantly correlated with PCP (r = 0.56; p < 0.001) and MCP (r = 0.47, p < 0.01) but not with CA (r = 0.23; n.s.). MME was significantly increased in varus alignment, compared to neutral or valgus alignment, with an intact medial meniscus. It was also significantly correlated with PCP and MCP within the medial compartment. However, valgus malalignment and neutral axis resulted in reduced MME and contact pressure. Lower limb alignment must be taken into account while assessing MME in clinical practice. Controlled laboratory study.