The horizontal reactive media treatment well (HRX Well®) uses directionally drilled horizontal wells filled with a treatment media to induce flow‐focusing behavior created by the well‐to‐aquifer permeability contrast to passively capture proportionally large volumes of groundwater. Groundwater is treated in situ as it flows through the HRX Well and downgradient portions of the aquifer are cleaned via elution as these zones are flushed with clean water discharging from the HRX Well. The HRX Well concept is particularly well suited for sites where long‐term mass discharge control is a primary performance objective. This concept is appropriate for recalcitrant and difficult‐to‐treat constituents, including chlorinated solvents, per‐ and polyfluoroalkyl substances (PFAS), 1,4‐dioxane, and metals. A full‐scale HRX Well was installed and operated to treat trichloroethene (TCE) with zero valent iron (ZVI). The model‐predicted enhanced flow through the HRX Well (compared to the flow in and equivalent cross‐sectional area orthogonal to flow in the natural formation before HRX Well installation) and treatment zone width was consistent with flows and widths estimated independently by point velocity probe (PVP) testing, HRX Well tracer testing, and observed treatment in downgradient monitoring wells. The actual average capture zone width was estimated to be between 45 and 69 feet. Total TCE mass discharge reduction was maintained through the duration of the performance monitoring period and exceeded 99.99% (%). Decreases in TCE concentrations were observed at all four downgradient monitoring wells within the treatment zone (ranging from 50 to 74% at day 436), and the first arrival of treated water was consistent with model predictions. The field demonstration confirmed the HRX Well technology is best suited for long‐term mass discharge control, can be installed under active infrastructure, requires limited ongoing operation and maintenance, and has low life cycle energy and water requirements.
The horizontal reactive media treatment well (HRX Well (R)) uses directionally drilled horizontal wells filled with a treatment media to induce flow-focusing behavior created by the well-to-aquifer permeability contrast to passively capture proportionally large volumes of groundwater. Groundwater is treated in situ as it flows through the HRX Well and downgradient portions of the aquifer are cleaned via elution as these zones are flushed with clean water discharging from the HRX Well. The HRX Well concept is particularly well suited for sites where long-term mass discharge control is a primary performance objective. This concept is appropriate for recalcitrant and difficult-to-treat constituents, including chlorinated solvents, per- and polyfluoroalkyl substances (PFAS), 1,4-dioxane, and metals. A full-scale HRX Well was installed and operated to treat trichloroethene (TCE) with zero valent iron (ZVI). The model-predicted enhanced flow through the HRX Well (compared to the flow in and equivalent cross-sectional area orthogonal to flow in the natural formation before HRX Well installation) and treatment zone width was consistent with flows and widths estimated independently by point velocity probe (PVP) testing, HRX Well tracer testing, and observed treatment in downgradient monitoring wells. The actual average capture zone width was estimated to be between 45 and 69 feet. Total TCE mass discharge reduction was maintained through the duration of the performance monitoring period and exceeded 99.99% (%). Decreases in TCE concentrations were observed at all four downgradient monitoring wells within the treatment zone (ranging from 50 to 74% at day 436), and the first arrival of treated water was consistent with model predictions. The field demonstration confirmed the HRX Well technology is best suited for long-term mass discharge control, can be installed under active infrastructure, requires limited ongoing operation and maintenance, and has low life cycle energy and water requirements.
A new in situ remediation concept termed a Horizontal Reactive Media Treatment Well (HRX Well((R))) is presented that utilizes a horizontal well filled with reactive media to passively treat contaminated groundwater in situ. The approach involves the use of a large-diameter directionally drilled horizontal well filled with solid reactive media installed parallel to the direction of groundwater flow. The engineered contrast in hydraulic conductivity between the high in-well reactive media and the ambient aquifer hydraulic conductivity results in the passive capture, treatment, and discharge back to the aquifer of proportionally large volumes of groundwater. Capture and treatment widths of up to tens of feet can be achieved for many aquifer settings, and reductions in downgradient concentrations and contaminant mass flux are nearly immediate. Many different types of solid-phase reactive treatment media are already available (zero valent iron, granular activated carbon, biodegradable particulate organic matter, slow-release oxidants, ion exchange resins, zeolite, apatite, etc.). Therefore, this concept could be used to address a wide range of contaminants. Laboratory and pilot-scale test results and numerical flow and transport model simulations are presented that validate the concept. The HRX Well can access contaminants not accessible by conventional vertical drilling and requires no aboveground treatment or footprint and requires limited ongoing maintenance. A focused feasibility evaluation and alternatives analysis highlights the potential cost and sustainability advantages of the HRX Well compared to groundwater extraction and treatment systems or funnel and gate permeable reactive barrier technologies for long-term plume treatment. This paper also presents considerations for design and implementation for a planned upcoming field installation.
Smart characterization approaches apply the latest high‐resolution site characterization methods to find the contaminant mass flux, by integrating relative permeability mapping, classical hydrostratigraphy interpretation, and high‐density groundwater and saturated soil sampling. The key factor that makes Smart characterization different is the application of quantitative saturated soil sampling in less permeable slow advection and storage zones to diagnose plume maturity and understand its implications for remedy selection and performance. Because direct sensing tools like the membrane interface probe are capable of providing screening‐level assessments for hydrocarbons and chlorinated solvents in storage zones, but not 1,4‐dioxane, the recommended Smart approach involves application of specialized high‐capacity mobile laboratories or rapid turn‐around using fixed commercial labs. In addition to the benefit of rapidly characterizing sites, Smart characterization facilitates a flux‐based conceptual site model, which allows stakeholders to focus remedies on the mobile portion of the contaminant mass or, in effect, the mass that matters. Through systematic planning and implementation, predesign characterization can be completed to optimize source and plume remedy strategies, balancing investment in Smart characterization with reductions in total life‐cycle costs to ensure that an appropriate return on investigation is obtained. © 2016 Wiley Periodicals, Inc.