Wide field-of-view (WFOV) lenses covering a full field of view of <120° have been designed and analyzed for spaceborne applications for use in severe environments. The optical designs have been passively athermalized and achromatized over the visible waveband for use during operating conditions and the opto-mechanical designs have been ruggedized for survivability in severe environmental conditions with random vibration levels exceeding 2000 Grms and cryogenic temperature conditions reaching -175°C. To characterize the performance and survivability of the lens assembly for such environments, image quality and random vibration testing was performed on representative optical assemblies, with previous flight experience, before and after exposure to cryogenic liquid nitrogen temperatures. The dynamic test environment consists of low-level random vibration testing in each of the three orthogonal axes (X, Y & Z) and the image quality testing performed includes resolution (MTF), distortion, and effective focal (EFL). Finite element analysis (FEA) was performed to verify survivability to full random vibration spectrums and shock levels; external testing was performed with flight hardware and results were validated. High correlation of characterization measurements before and after cryogenic exposure indicate the optical assemblies' ability to withstand severe temperature environments without any impact to functionality or performance. This document provides an overview of the optical and opto-mechanical lens designs for severe space environments, a comprehensive look into component material characteristics over temperature for various space-grade adhesives used to mechanically retain lens elements, and detailed explanations of the cryogenic test methodology using a custom laboratory test setup to characterize the performance and survivability of lens assemblies and their various components.
OBJECTIVE:Minimally invasive, image-guided cochlear implantation (CI) surgery consists of drilling a precise tunnel from the surface of the mastoid cortex through the facial recess to target the scala tympani. In the first set of clinical trials of this technique, heat-induced facial nerve paresis (House-Brackmann II/VI) occurred on a patient on the last day of the initial trial which was scheduled to be halted secondary to a change in the regulatory requirements dictated by the 2012 the Food and Drug Administration Safety and Innovation Act requiring Investigational Device Exemption approval for previously exempted customized medical device testing. To address this adverse event, extensive changes were made to the drilling protocol; additionally, a custom insertion tool was developed. To address the Food and Drug Administration Safety and Innovation Act, an Investigational Device Exemption was submitted and, subsequently approved. Herein is described our first clinical implementation of the modified technique.PATIENT:Seventy-year-old with profound, postlingual sensorineural hearing loss who had previously undergone right CI via traditional approach in 2015.INTERVENTION:Minimally invasive image-guided left CI.MAIN OUTCOME MEASURE:Time of intervention, final location of CI electrode array within cochlea.RESULTS:Surgery took 155 minutes of which the largest components (in descending order) were soft tissue work, closure, and drilling. Full scala tympani insertion with angular insertion depth of 557 degrees of the electrode array was achieved. There were no complications, and the patient had an uneventful recovery and activation.CONCLUSIONS:Minimally invasive, image-guided CI surgery is achievable and reduces the mastoid depression associated with traditional CI surgery.CLINICALTRIALSGOV INFORMATION:Study NCT03101917, Microtable Microstereotactic Frame and Drill Press and Associated Method for Cochlear Implantation.LEVEL OF EVIDENCE:Case Report.
Mastoid cells as well as trabecula provide unique bone structures, which can serve as natural landmarks for registration. Preoperative imaging enables sufficient acquisition of these structures, but registration requires an intraoperative counterpart. Since versatile surgical interventions involve drilling into mastoid cells and trabecula, we propose a registration method based on endoscopy inside of these drill holes.
This paper describes the design and delivery of a highly successful MOOC that uses MATLAB to teach introductory computer programming to a wide audience. The decisions behind the curriculum and assessment strategy are detailed, and the results are evaluated based on three sessions of the course that saw 80,000 active students, two million lecture views and 100,000 auto-graded programming assignment sets during the three sessions delivered in 2015.
Safe and effective planning for robotic surgery that involves cutting or ablation of tissue must consider all potential sources of error when determining how close the tool may come to vital anatomy. A pre-operative plan that does not adequately consider potential deviations from ideal system behavior may lead to patient injury. Conversely, a plan that is overly conservative may result in ineffective or incomplete performance of the task. Thus, enforcing simple, uniform-thickness safety margins around vital anatomy is insufficient in the presence of spatially varying, anisotropic error. Prior work has used registration error to determine a variable-thickness safety margin around vital structures that must be approached during mastoidectomy but ultimately preserved. In this paper, these methods are extended to incorporate image distortion and physical robot errors, including kinematic errors and deflections of the robot. These additional sources of error are discussed and stochastic models for a bone-attached robot for otologic surgery are developed. An algorithm for generating appropriate safety margins based on a desired probability of preserving the underlying anatomical structure is presented. Simulations are performed on a CT scan of a cadaver head and safety margins are calculated around several critical structures for planning of a robotic mastoidectomy.
BACKGROUND:When robots mill bone near critical structures, safety margins are used to reduce the risk of accidental damage due to inaccurate registration. These margins are typically set heuristically with uniform thickness, which does not reflect the anisotropy and spatial variance of registration error.METHODS:A method is described to generate spatially varying safety margins around vital anatomy using statistical models of registration uncertainty. Numerical simulations are used to determine the margin geometry that matches a safety threshold specified by the surgeon.RESULTS:The algorithm was applied to CT scans of five temporal bones in the context of mastoidectomy, a common bone milling procedure in ear surgery that must approach vital nerves. Safety margins were generated that satisfied the specified safety levels in every case.CONCLUSIONS:Patient safety in image-guided surgery can be increased by incorporating statistical models of registration uncertainty in the generation of safety margins around vital anatomy.
Robots have been shown to be useful in assisting surgeons in a variety of bone drilling and milling procedures. Examples include commercial systems for joint repair or replacement surgeries, with in vitro feasibility recently shown for mastoidectomy. Typically, the robot is guided along a path planned on a CT image that has been registered to the physical anatomy in the operating room, which is in turn registered to the robot. The registrations often take advantage of the high accuracy of fiducial registration, but, because no real-world registration is perfect, the drill guided by the robot will inevitably deviate from its planned path. The extent of the deviation can vary from point to point along the path because of the spatial variation of target registration error. The allowable deviation can also vary spatially based on the necessary safety margin between the drill tip and various nearby anatomical structures along the path. Knowledge of the expected spatial distribution of registration error can be obtained from theoretical models or experimental measurements and used to modify the planned path. The objective of such modifications is to achieve desired probabilities for sparing specified structures. This approach has previously been studied for drilling straight holes but has not yet been generalized to milling procedures, such as mastoidectomy, in which cavities of more general shapes must be created. In this work, we present a general method for altering any path to achieve specified probabilities for any spatial arrangement of structures to be protected. We validate the method via numerical simulations in the context of mastoidectomy.
Otologic surgery often involves a mastoidectomy, which is the removal of a portion of the mastoid region of the temporal bone, to safely access the middle and inner ear. The surgery is challenging because many critical structures are embedded within the bone, making them difficult to see and requiring a high level of accuracy with the surgical dissection instrument, a high-speed drill. We propose to automate the mastoidectomy portion of the surgery using a compact, bone-attached robot. The system described in this paper is a milling robot with four degrees-of-freedom (DOF) that is fixed to the patient during surgery using a rigid positioning frame screwed into the surface of the bone. The target volume to be removed is manually identified by the surgeon pre-operatively in a computed tomography (CT) scan and converted to a milling path for the robot. The surgeon attaches the robot to the patient in the operating room and monitors the procedure. Several design considerations are discussed in the paper as well as the proposed surgical workflow. The mean targeting error of the system in free space was measured to be 0.5 mm or less at vital structures. Four mastoidectomies were then performed in cadaveric temporal bones, and the error at the edges of the target volume was measured by registering a postoperative computed tomography (CT) to the pre-operative CT. The mean error along the border of the milled cavity was 0.38 mm, and all critical anatomical structures were preserved.
In recent years, bone-attached robots and microstereotactic frames have attracted increasing interest due to the promising targeting accuracy they provide. Such devices attach to a patient's skull via bone anchors, which are used as landmarks during intervention planning as well. However, as simulation results reveal, the performance of such mechanisms is limited by errors occurring during the localization of their bone anchors in preoperatively acquired computed tomography images. Therefore, it is desirable to identify the most suitable fiducials as well as the most accurate method for fiducial localization. We present experimental results of a study focusing on the fiducial localization error (FLE) of spheres. Two phantoms equipped with fiducials made from ferromagnetic steel and titanium, respectively, are used to compare two clinically available imaging modalities (multi-slice CT (MSCT) and cone-beam CT (CBCT)), three localization algorithms as well as two methods for approximating the FLE. Furthermore, the impact of cubic interpolation applied to the images is investigated. Results reveal that, generally, the achievable localization accuracy in CBCT image data is significantly higher compared to MSCT imaging. The lowest FLEs (approx. 40 pm) are obtained using spheres made from titanium, CBCT imaging, template matching based on cross correlation for localization, and interpolating the images by a factor of sixteen. Nevertheless, the achievable localization accuracy of spheres made from steel is only slightly inferior. The outcomes of the presented study will be valuable considering the optimization of future microstereotactic frame prototypes as well as the operative workflow.
ObjectiveMinimally invasive image‐guided cochlear implantation (CI) involves accessing the cochlea via a linear path from the lateral skull to the cochlea avoiding vital structures including the facial nerve. Herein, we describe and demonstrate the feasibility of the technique for pediatric patients.Study DesignProspective.SettingChildren's Hospital.Subjects and MethodsThirteen pediatric patients (1.5 to 8 years) undergoing traditional CI participated in this Institutional Review Board–approved study. Three fiducial markers were bone‐implanted surrounding the ear, and a CT scan was acquired. The CT scan was processed to identify the marker locations and critical structures of the temporal bone. A safe linear path was determined to target the cochlea avoiding damage to vital structures. A custom microstereotactic frame was fabricated that would mount on the fiducial markers and constrain a tool to the desired trajectory. After traditional mastoidectomy and prior to cochleostomy, the custom microstereotactic frame was mounted on the bone‐implanted markers to confirm that the achieved trajectory was safe and accurately accessed the cochlea.ResultsFor all the 13 patients, it was possible to determine a safe trajectory to the cochlea. Custom microstereotactic frames were validated successfully on 9 patients. Two of these patients had inner ear malformations, and this technique helped the surgeon confirm ideal location for cochleostomy. For patients with normal anatomy, the mean and standard deviation of the closest distance of the trajectory to facial nerve and chorda tympani were 1.1 ± 0.3 mm and 1.2 ± 0.5 mm, respectively.ConclusionMinimally invasive image‐guided CI is feasible for pediatric patients.
In 1996 Freeborough proposed a method for estimating target registration error (TRE) in the absence of ground truth. In his approach, a circuit of registrations is performed using the same registration method on multiple views of the same object: 1 to 2, 2 to 3, …, Nc –1 to Nc , and Nc to 1 where Nc is at least three and the last registration completes the circuit. Any difference between the original and final positions, which we call the “Circuit TRE” or TREc, indicates that at least one step in the registration method suffers from TRE. To estimate the mean single-step error, Freeborough proposed the formula, True TRE = k × TREc, and suggested that k = 1/square-root-of-Nc. Multiple articles have employed Freeborough’s approach to estimate the accuracy of intensity-based registration methods with various values of k, but no theoretical analysis of the expected accuracy of such estimates has been attempted for any registration method. As a first step in this direction, the current work provides such an analysis for the method of rigid point registration, also known as fiducial registration. The analysis, which is validated via computer simulation, reveals that for point registration Freeborough’s formula greatly underestimates TRE. The simulations further reveal that, to an excellent approximation, True TRE = k ×square-root-of-TREc, where k depends not only on the number of points but also on their configuration. We investigate the usefulness of this formula as a means to estimate true TRE. We find that it is less reliable than a standard formula published in 1998.
Otologic surgery often involves a mastoidectomy procedure, in which part of the temporal bone is milled away in order to visualize critical structures embedded in the bone and safely access the middle and inner ear. We propose to automate this portion of the surgery using a compact, bone-attached milling robot. A high level of accuracy is required to avoid damage to vital anatomy along the surgical path, most notably the facial nerve, making this procedure well-suited for robotic intervention. In this study, several of the design considerations are discussed and a robot design and prototype are presented. The prototype is a 4 degrees-of-freedom robot similar to a four-axis milling machine that mounts to the patient's skull. A positioning frame, containing fiducial markers and attachment points for the robot, is rigidly attached to the skull of the patient, and a CT scan is acquired. The target bone volume is manually segmented in the CT by the surgeon and automatically converted to a milling path and robot trajectory. The robot is then attached to the positioning frame and is used to drill the desired volume. The accuracy of the entire system (image processing, planning, robot) was evaluated at several critical locations within or near the target bone volume with a mean free space accuracy result of 0.50 mm or less at all points. A milling test in a phantom material was then performed to evaluate the surgical workflow. The resulting milled volume did not violate any critical structures.
Objective Minimally invasive image-guided cochlear implantation (CI) involves accessing the cochlea via a linear path from the lateral skull to the cochlea avoiding vital structures including the facial nerve. Herein, we describe and demonstrate the feasibility of the technique for pediatric patients. Study Design Prospective. Setting Children’s Hospital. Subjects and Methods Thirteen pediatric patients (1.5 to 8 years) undergoing traditional CI participated in this Institutional Review Board–approved study. Three fiducial markers were bone-implanted surrounding the ear, and a CT scan was acquired. The CT scan was processed to identify the marker locations and critical structures of the temporal bone. A safe linear path was determined to target the cochlea avoiding damage to vital structures. A custom microstereotactic frame was fabricated that would mount on the fiducial markers and constrain a tool to the desired trajectory. After traditional mastoidectomy and prior to cochleostomy, the custom microstereotactic frame was mounted on the bone-implanted markers to confirm that the achieved trajectory was safe and accurately accessed the cochlea. Results For all the 13 patients, it was possible to determine a safe trajectory to the cochlea. Custom microstereotactic frames were validated successfully on 9 patients. Two of these patients had inner ear malformations, and this technique helped the surgeon confirm ideal location for cochleostomy. For patients with normal anatomy, the mean and standard deviation of the closest distance of the trajectory to facial nerve and chorda tympani were 1.1 ± 0.3 mm and 1.2 ± 0.5 mm, respectively. Conclusion Minimally invasive image-guided CI is feasible for pediatric patients.
Deep brain stimulation (DBS) surgery utilizes image guidance via bone-implanted fiducial markers to achieve the desired submillimetric accuracy and to provide means for attaching microstereotactic frames. For maximal benefit, the markers must be inserted to the correct depth since over-insertion leads to stripping and under-insertion leads to instability.
Background Registered medical images can assist with surgical navigation and enable image-guided therapy delivery. In soft tissues, surface-based registration is often used and can be facilitated by laser surface scanning. Tracked conoscopic holography (which provides distance measurements) has been recently proposed as a minimally invasive way to obtain surface scans. Moving this technique from concept to clinical use requires a rigorous accuracy evaluation, which is the purpose of our paper. Methods We adapt recent non-homogeneous and anisotropic point-based registration results to provide a theoretical framework for predicting the accuracy of tracked distance measurement systems. Experiments are conducted a complex objects of defined geometry, an anthropomorphic kidney phantom and a human cadaver kidney. Results Experiments agree with model predictions, producing point RMS errors consistently<1 mm, surface-based registration with mean closest point error<1 mm in the phantom and a RMS target registration error of 0.8 mm in the human cadaver kidney. Conclusions Tracked conoscopic holography is clinically viable; it enables minimally invasive surface scan accuracy comparable to current clinical methods that require open surgery. Copyright (c) 2012 John Wiley & Sons, Ltd.
Objectives/HypothesisMinimally invasive image‐guided approach to cochlear implantation (CI) involves drilling a narrow, linear tunnel to the cochlea. Reported herein is the first clinical implementation of this approach.Study DesignProspective cohort study.MethodsOn preoperative computed tomography (CT), a safe linear trajectory through the facial recess targeting the scala tympani was planned. Intraoperatively, fiducial markers were bone‐implanted, a second CT was acquired, and the trajectory was transferred from preoperative to intraoperative CT. A customized microstereotactic frame was rapidly designed and constructed to constrain a surgical drill along the desired trajectory. Following sterilization, the frame was employed to drill the tunnel to the middle ear. After lifting a tympanomeatal flap and performing a cochleostomy, the electrode array was threaded through the drilled tunnel and into the cochlea.ResultsEight of nine patients were successfully implanted using the proposed approach with six insertions completely within the scala tympani. Traditional mastoidectomy was performed on one patient following difficulty threading the electrode array via the narrow tunnel. Other difficulties encountered included use of the backup implant when an electrode was dislodged during threading via the tunnel, tip fold‐over, and facial nerve paresis (House‐Brackmann II/VI at 12 months) secondary to heat during drilling. The average time of intervention was 182 ± 36 minutes.ConclusionsMinimally invasive image‐guided CI is clinically achievable. Further clinical study is necessary to address technological difficulties during drilling and insertion, and to assess potential benefits including decreased time of intervention, standardization of surgical intervention, and decreased tissue dissection potentially leading to shorter recovery and earlier implant activation.Level of Evidence4. Laryngoscope, 124:1915–1922, 2014