High-temperature plasma-facing material coatings used for radio frequency (RF) launchers need to be robust enough to survive RF breakdown arcing or other transient events from the plasma (e.g., an edge localized mode) without causing a catastrophic failure of the coating. High-power transient effects are being explored by using an RF-induced vacuum arc to determine the robustness of tungsten coatings made by a variety of manufacturing methods. A 1/4-wavelength resonant section of vacuum transmission line terminated with an open circuit electrode structure with a well-defined electric field (30-60 kV/mm) produces repeatable arcing conditions. The initial focus is on tungsten as a plasma-facing material, including sintered tungsten, tungsten coatings on steel produced via physical vapor deposition (PVD), and functionally graded tungsten/steel coatings deposited by low-pressure plasma-spraying (LPPS). Thin PVD coatings (1-2 microns) fail catastrophically from an arc and result in severe delamination of the coating. The arc-induced damage of thicker coatings, such as those made via LPPS, tend to be restricted to the top few microns of the surface. Arcing often initiates on sharp surface microstructures and causes localized melting of tungsten at the surface of all the materials studied and results in resolidified melt pools with surface cracks. The resolidified surface results in a reduction in overall deuterium retention when exposed to typical RF plasma sheath conditions.
The filterscope diagnostic uses bandpass filters and photomultiplier tubes (PMTs) to detect specific spectral emission lines. A filterscope was used to measure the W I 400.88 nm line emission as a function of ion energy on the Radio Frequency Plasma Interaction Experiment (RF PIE) for the purpose of assessing W erosion on plasma-facing components (PFCs). Different filter techniques are being explored and compared in order to effectively screen out nearby impurity lines, like the Ar II 401.39 nm line. The effectiveness of these techniques is determined by comparing the measurements to a high-resolution 1.0 m Czerny-Turner spectrometer with 0.012 nm spectral resolution. The ability to filter out nearby impurity emissions is useful when imaging PFCs in fusion devices including divertor and antenna guard limiters. Initial results with a helium plasma show little difference between the two techniques at higher bias voltages. In a helium plasma at lower dc bias voltages, a two-filter technique with filters at two separate wavelengths was shown to be more effective at screening out background signals. Data collected with an argon plasma however show the technique with overlapping filters on the line of interest is a closer match to spectrometer data at lower dc bias voltages.
Linear plasma devices used to test plasma facing materials (PFMs) and components for fusion reactors are often suffering under the production of intrinsic impurities from the plasma source system. Most linear plasma devices use internal electrodes (hollow cathodes, reflex arc, or cascading arc), which typically are the source of the main impurities. The next-generation plasma generators use radio frequency (RF) plasma sources like helicons to avoid internal electrodes. However, high power operation of helicons has proven to result in impurity production due to the high rectified sheath voltages created. Depending on the plasma parameters and magnetic configuration, these impurities can be transported to the target and deposited there to unacceptable high levels. In this contribution, the experimental results from Proto-MPEX are summarized, and the conclusions of the impurity source physics are given. Methods to reduce the impurity production, the impurity transport, and the net deposition on the target are presented. These methods to reduce the impurity production include Faraday screens to reduce the sheath voltage drop, high- $Z$ refractory coatings to reduce the erosion yield, and wall conditioning methods. Methods to reduce the impurity transport include changes in the magnetic configuration as well as electron heating to change axial and radial temperature profiles. Preliminary results on the effectiveness of some of these methods are presented.
The interaction of radio frequency (RF) sheaths with fusion reactor relevant materials (e.g., tungsten and titanium diboride) is being studied on the RF Plasma Interaction Experiment (RF PIE). The RF PIE consists of an electron cyclotron resonance (ECR) plasma source (2.45 GHz, 5 kW) with a biased and heated RF electrode that is used to simulate antenna surfaces in contact with the edge plasma. Helium plasmas (density of similar to 1e18/m(3) , electron temperature of 4-5 eV) are being used to explore sheath formation on material surfaces with biases up to 500 V. The erosion of a tungsten surface is being studied spectroscopically using a mirror-linked 1 m Czerny-Turner UV imaging spectrometer with a spectral resolution of 0.012 nm for measuring plasma emission in and near the sheath. Tungsten line emission intensity is higher for RF versus dc biasing for similar plasma conditions and average ion energy. RF biasing causes a broadening of the ion energy distribution function (IEDF) due to the RF sheath, as determined from the hPIC2 code, and results in enhanced sputtering. Calculations of the expected sputtering yield for dc and RF biasing are consistent with experimental observations of changes in the 400.9 nm tungsten line emission intensity as a function of ion energy.
The Materials Plasma Exposure eXperiment (MPEX) is a steady-state linear plasma device that will address plasma-material interaction (PMI) science and enable testing of fusion reactor-relevant divertor plasma-facing materials. The MPEX source concept consists of a helicon plasma source to generate the plasma, electron cyclotron heating (ECH) for electron heating, and ion cyclotron heating (ICH) for ion heating. The MPEX source plasma is then transported axially to the PMI material target region to test material samples in fusion reactor-relevant divertor conditions. This paper will summarize the physical and technical basis of MPEX. The paper will first define the MPEX parameters and scenarios at the target relevant to PMI science for various fusion reactor-relevant divertor conditions and show plasma transport modeling results to set the MPEX source parameters. Recent experimental and modeling results from Proto-MPEX, a short-pulse experiment to develop the plasma production, heating, and transport physics for MPEX, will be shown. From these results, it will be shown that MPEX can reach its desired scenarios. The MPEX physical and technical basis will also determine important functional requirements for magnetic field, radiofrequency (RF) power, RF frequency, and neutral pressure in the helicon, ECH, ICH, and PMI regions that are required to achieve the desired MPEX scenarios. The necessity for key in-vessel components such as skimmers, limiters, and microwave absorbers will also be highlighted.
The physics of ion cyclotron heating (ICH) relevant to the steady-state linear machine MPEX (Material Plasma Exposure eXperiment) has been explored in its predecessor, short-pulse device: Proto-MPEX. MPEX will utilize fundamental ICH to increase heat flux at the target and produce ion temperatures and velocity distributions with improved fidelity to those found in a tokamak divertor region, in comparison to those produced by substrate biasing. In the experiments on Proto-MPEX described here, bulk ion temperatures up to ∼ 15 eV have been achieved with 20 kW net ICH power at 6.5 MHz, using ICH heating of a deuterium plasma produced by a helicon plasma source. The heat flux at the target has been observed to increase throughout the plasma cross section, including in the core region. Core Ti and target heat flux are observed to scale linearly with injected ICH power. Measurements of plasma loading and target heat flux as a function of the magnetic field strength at the antenna, together with modeling of the wave propagation from the antenna to the ion cyclotron resonance using the ANTENA and COMSOL codes with a warm plasma dielectric tensor, indicate that power is coupled to the core plasma via fast wave excitation of a kinetic Alfvén wave.
The Material Plasma Exposure eXperiment (MPEX) has completed its design phase. MPEX will be a unique facility to investigate plasma material interactions (PMIs) under fusion prototypic divertor conditions in steady state. This includes plasma exposure conditions expected in a fusion reactor divertor. Materials to be investigated will include solids, liquids, and neutron pre-irradiated materials. Electron and ion heating will allow for a large operational domain ranging from erosion-dominated PMI conditions to deposition-dominated PMI conditions. An overview of the final design for all MPEX systems is given. In particular, it is shown how mission-driven project requirements have led to detailed design choices with innovative solutions. Examples are the water-cooled helicon window, the electron cyclotron heating launcher, the target holder and manipulator, and the autonomous decouplers.
The principal objective of this work is to report on the power coupled to a tungsten target in the prototype-material plasma exposure experiment device during oblique injection of a microwave beam (<70 kW at 28 GHz) into a high-power (∼100 kW at 13.56 MHz) over-dense ( 1 \times {10^{19}}{\text{ }}{{\text{m}}^{ - 3}}$?> ne>1×1019 m−3 ) deuterium helicon plasma column. The experimental setup, electron heating system, electron heating scheme, and IR thermographic diagnostic for quantifying the power transport is described in detail. It is demonstrated that the power transported to the target can be effectively controlled by adjusting the magnetic field profile. Using this method, heat fluxes up to 22 MW m−2 and power transport efficiencies in the range of 17%–20% have been achieved using 70 kW of microwave power. It is observed that most of the heat flux is confined to a narrow region at the plasma periphery. Ray-tracing calculations are presented which indicate that the power is coupled to the plasma electrons via an O-X-B mode conversion process. Calculations indicate that the microwave power is absorbed in a single pass at the plasma periphery via collisions and in the over-dense region via 2nd harmonic cyclotron resonance of the electron Bernstein wave. The impact of these results is discussed in the context of MPEX.
The Prototype Material Plasma Exposure eXperiment (Proto-MPEX) is a pulsed linear plasma device that uses a radio frequency (RF) helicon antenna and a helicon ceramic window as the plasma ionization source. Modeling performed within this work on the helicon operations predicts hot spots on the helicon ceramic window due to an RF-induced sheath. The RF sheath potential leads to physical sputtering of the ceramic window predominantly where the helicon antenna sits around the helicon window. The role of oxygen in sputtering within Proto-MPEX is also investigated and is needed to match the experimental data. Experiments on Proto-MPEX show reasonable agreement with the modeled erosion/redeposition pattern on the helicon window, and the modeled impurity flux to the target shows radial transport within the device as expected from classical collisional impurity transport. Temperature screening of impurities is shown to be needed for Proto-MPEX to reduce impurity flux to the target. The modeling approach used in this work can be applied to other plasma RF applications for the determination of impurity production and transport.
The light-ion helicon plasma source of the Proto-MPEX linear plasma device has been recently upgraded to enable pulsed (0.5–1 s) operation up to 200 kW. The main objective of this work is to report on the plasma-induced surface heat fluxes incident on the helicon window during high power operation (60–150 kW net power) for the purpose of the design of the upcoming material plasma exposure eXperiment (MPEX). The IR imaging system and associated physics models for the extraction of surface heat fluxes are presented. Experimental results demonstrate that the control of the plasma strike point via magnetic flux mapping and the use of dedicated limiters is effective at reducing the heat loads on the dielectric window. Moreover, it is found that the flux mapping must create a gap between the plasma and the dielectric window of at least the plasma radial decay length. Extrapolated to 200 kW net RF power, this mode of operation can reduce the power lost to the dielectric window by 33%. The results presented have direct application to the design of high-powered helicon plasma sources that operate in a steady state. Examples include linear divertor simulators such as MPEX, electric thrusters, negative ion sources for NBI and linear plasma–material interaction test stands.
Shattered pellet injection (SPI) systems that form cryogenic pellets in a pipe-gun for injection of material to mitigate disruptions have been fabricated and installed for use in thermal mitigation and runaway electron (RE) dissipation experiments on JET and KSTAR. These systems are to support disruption mitigation research for ITER and are based on an ORNL three-barrel design for flexibility in pellet size selection and variable pellet composition studies. The SPI systems for JET and KSTAR have a common feature of the barrels being collimated into a single injection line that enters the vacuum vessel. The pellets are shattered in bent stainless steel tubes that are mounted inside the vacuum vessel of the tokamak, vertically on JET and horizontally on KSTAR. The JET installation has the unique feature of vertical SPI mounting and injection with the shatter plume aimed toward the inner wall to intercept known RE beam locations generated from argon gas injection induced disruptions. The KSTAR SPI installation has two identical SPIs that are mounted on the midplane 180 degrees apart with identical injection lines and shatter tubes aimed at the plasma magnetic axis. Installation and operation of these SPI systems has provided useful lessons learned in the implementation of this SPI technology and valuable experience in optimizing the formation and firing of the pellets to optimize the physics performance.
The Prototype Material Plasma Exposure eXperiment (Proto-MPEX) is a linear plasma device being used in plasma source research and development (R&D) for the proposed MPEX. Once the R&D is completed, this device can also be used to perform plasma-material interaction studies. To perform these studies, a new materials analysis and particle probe (MAPP) has been constructed. The MAPP's components are a sample holder and manipulator and a custom vacuum chamber with ports to facilitate surface chemistry diagnostics. The MAPP's overall design enables rapid sample turnaround and in vacuo surface characterization. The surface analysis vacuum chamber has ports for x-ray photoelectron spectroscopy, thermal desorption spectroscopy, back-scatter ion scattering spectroscopy, forward-scatter ion scattering spectroscopy, and direct recoil spectroscopy. The sample manipulator and holder is a Lesker/UHV Multi-Centre Analytical Stage, which is used to place the samples in the exposure region of the Proto-MPEX or the analysis position in the MAPP vacuum chamber. The sample holder has a heating capability of up to 1200 °C for heated exposure and for desorption studies. In this work, we present the MAPP's design and the first tungsten sample exposure with ex situ analysis that shows a surface deposition layer on the exposed target, highlighting the need for additional in situ measurements on the Proto-MPEX.
•New linear plasma device MPEX will address plasma material interaction gaps for fusion.•MPEX will have increased capabilities over existing linear plasma devices and will be world-leading when completed.•MPEX will expose apriori neutron irradiated material samples for fusion reactor divertor relevant heat and particle fluxes.•The conceptual design of MPEX is finished.
The Prototype Material Plasma Exposure eXperiment (Proto-MPEX) is a linear plasma device located at Oak Ridge National Laboratory to develop the plasma source concept for the Materials Plasma Exposure eXperiment (MPEX). Recent experiments have demonstrated the heating of electrons in a high-density deuterium plasma (n(e) similar to 5 x 10(19) m(-3)) via electron Bernstein waves and source plasma production via helicon waves in this linear configuration. Moreover, experimental observations suggest that the magnetic ripple adversely affects the parallel transport of the heated electrons toward the target where material samples are to be exposed to the plasma. To understand the transport process during microwave application, a test-particle Monte-Carlo (MC) code has been developed that incorporates the effects of Coulomb collisions, magnetic mirror adiabatic trapping and electron cyclotron interaction via a quasilinear RF heating operator. MC calculations indicate that the absence of 2nd turning points along the trajectory of cyclotron heated electrons significantly reduces adiabatic trapping and maximizes power transport to the Target surface. Thermalization of cyclotron heating electrons is analyzed with the MC code and it is found that for conditions relevant to Proto-MPEX, a significant fraction of the absorbed heating power is coupled to the Target surface via ballistic fast electrons; however, under certain conditions, up to 60% of the absorbed RF power can be dissipated via thermalization of the fast electrons on the background plasma. Results are compared with experimental measurements. Finally, the implications of the results are discussed in the context of the upcoming MPEX device.
The Materials Plasma Exposure eXperiment (MPEX) is a linear plasma device that will address the plasma-material interaction (PMI) science for future fusion reactors and will enable testing of plasma-facing components (PFCs). It is designed as a steady-state device eventually delivering an ion fluence of up to 10(31) m(-2) to the target. The device will be designed to handle neutron-activated materials. These capabilities should push the technical readiness level of PFCs up to six for some end-of-life aspects. In order to achieve the relevant plasma conditions, as they are expected in future fusion reactor divertors, MPEX will utilize a novel plasma source concept. This plasma source concept uses a high-power helicon (200 kW, 13.56 MHz), an electron cyclotron heating (ECH) system, which will heat electrons via electron Bernstein wave (EBW) heating (about 400 kW, 70 GHz), and an ion cyclotron heating (ICH) system (400 kW, 6-9 MHz). The physics basis for this plasma source concept including the heating physics and transport is based on experiments on Proto-MPEX. An overview of the experimental results and the physics basis will be given. The physics basis directly translates into functional requirements of MPEX and the conceptual design. The status of the conceptual design of MPEX will be shown.
The Prototype Material Plasma Exposure eXperiment (Proto-MPEX) is a linear device used to develop the source and heating concept for MPEX, an experiment to study plasma-material interactions for future fusion reactors. This article will highlight recent analysis and results on Proto-MPEX using an infrared (IR) camera, a key tool for imaging heat fluxes measured at the material target. The target heat fluxes are crucial to understanding the source and heating concepts. The recent analysis includes the application of homography and 3-D finite-element methods to provide between-shot measurements of the 2-D target heat flux profile. The IR camera inferred heat flux is shown to correlate with Langmuir probe inferred heat fluxes for a range of parameters in helicon only and helicon + electron cyclotron heated discharges. Results show both desirable central and undesirable edge heat flux for helicon source and electron heating on the target. These heat flux measurements are shown to be important for better understanding of the source and heating physics.
The Prototype Material Plasma Exposure eXperiment (Proto-MPEX) at Oak Ridge National Laboratory is developing a helicon radio frequency (RF) source for plasma production along with microwave electron heating and RF ion heating. Proto-MPEX has several magnetic mirrors that affect plasma transport. The magnetic field near the helicon source is similar to 0.05 T, and the peak magnetic field in Proto-MPEX is similar to 1.8 T, which results in a large magnetic well for particles sourced at the helicon transporting toward the target region. Keeping the helicon source field and the target field constant, experiments have been conducted by methodically changing the magnetic field, at a local axial location, within the source and the target. Plasma flow measurements using Mach probes have shown a decrease in the flow as a function of the magnetic mirror ratio. Plasma flows were further investigated with ion cyclotron resonant heating (ICH). Results with the addition of ICH measured upstream of the antenna have shown a decrease in Mach number as a function of mirror ratio when compared to helicon discharges. Such flow behavior demonstrated slowing down of the plasma due to the increased reverse plasma flow toward the helicon plasma source. However, in high magnetic fields, when the resonant magnetic field moved away from the ICH antenna, no effects on the plasma flow due to ICH were observed.
The Prototype Material Plasma Exposure eXperiment (Proto-MPEX) is being used to qualify the plasma source and heating systems for the Material Plasma Exposure eXperiment (MPEX). The MPEX will address important and urgent research needs on plasma material interactions for future fusion reactors. In MPEX, plasma-facing components (nonirradiated and a priori neutron irradiated) will be exposed to plasma conditions as they are expected in future fusion reactors. The MPEX, a steady-state device enabled by superconducting magnets, will be able to break into new ground by assessing plasma-facing materials and components at an ion fluence level in the range of 10(30) to 10(31)?m(?2). To achieve the relevant plasma conditions, high-density plasmas (>4???10(19)?m(?3)) are produced with a high-power helicon source. The so-produced low-temperature helicon plasma is then additionally heated with waves in the ion cyclotron resonance frequency and electron cyclotron resonance frequency domains. Proto-MPEX has achieved all key parameters (source n(e), source T-e, source T-i, target T-e, target T-i, target ion flux, and target heat flux) within a factor of 2 of the design requirements of MPEX, albeit not simultaneously. These parameters were achieved with a total installed heating power of 330?kW, which is less than half of the planned heating power in the MPEX (800?kW). An overview of the latest results from Proto-MPEX is given. These results are shown in relationship to the MPEX system goals. Remaining necessary research and development tasks are discussed. The MPEX is currently in the conceptual design phase. The status of the design and an overview of the system requirements are presented.