Debonding of cemented bone implants is regarded as a major contributor to complications. The relationship between shear bond strength and surface roughness has been investigated, however there are inconsistencies in the trends reported in different studies. The shear strength between poly(methyl methacrylate) bone-cement and sand blasted cobalt–chromium and titanium alloy surfaces was measured to investigate the relationship between interfacial shear strength and surface topology. Surface roughness was quantified by a power law relationship fitted to Fourier spectra as well as three traditional parameters (arithmetical average roughness (Ra), volume of interdigitation (Rr), and RMS slope (Rdq)). We found that the interfacial shear strength is directly proportional to the exponent of the surfaces power spectra (P2) and Rdq, but not to Ra and Rr. However, Rdq is shown to be critically dependent on sampling frequency, making it sensitive to measurement settings. P2 was found to be a robust measure of the surface roughness being independent of sampling frequency.
Objectives. Fracture strength measured in vitro indicates that most all-ceramic crowns should be able to withstand mastication forces. Nevertheless, fractures are one of the major clinical problems with all-ceramic restorations. Furthermore, the fracture mode of all-ceramic crowns observed in clinical use differs from that found in conventional fracture strength tests. The aim of the present study was to develop and investigate a method that simulates clinical fracture behavior in vitro.Methods. 30 crowns with alumina cores were made to fit a cylindrical model with a molar-like preparation design. These crowns were randomly allocated to 3 tests groups (n = 10). The crowns in group 1 were cemented to abutment models of epoxy and subsequently fractured by occlusal loading without contact damage. The crowns in group 2 were fractured by cementation with expanding cement. The crowns in group 3 were cemented on an abutment model of epoxy split almost in two and fractured by increasing the diameter of the model in the bucco-lingual direction. The fractured crowns were analyzed by fractographic methods and compared to a reference group of 10 crowns fractured in clinical use.Results. The fracture modes of all the in vitro crowns were similar to clinical fracture modes. The fracture modes in group 1 were most closely matched to the clinical fractures. These crowns also fractured at clinically relevant loads.Conclusion. Laboratory tests that induce a distortion of the abutment model during occlusal loading without occlusal contact damage can simulate clinical fractures of all-ceramic crowns. (C) 2013 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.