Transperineal ultrasound-guided prostate biopsy (TPPBx) under local anesthesia is becoming increasingly utilized due to its lower infection risk compared to transrectal ultrasound-guided prostate biopsy. Despite its increasing utilization, patient experience with this procedure remains an area requiring further investigation. This study aims to evaluate patient satisfaction and tolerance of outpatient free-hand ultrasound-guided transperineal prostate biopsy (TPPBx), focusing on patient experiences during and after the procedure, and its impact on quality of life. A prospective cohort study was conducted on 120 men undergoing TPPBx, using 2 standardized questionnaires; the day after the procedure and at follow-up 3–4 weeks later. Data on pain, post-procedural symptoms, and overall satisfaction were collected. Of the 120 participants, 97 completed both questionnaires (81
Pulmonary fat embolism (PFE) is a recognised complication of long bone fractures. The majority of cases represent microscopic embolism and are not detectable at CT pulmonary arteriography (CTPA). CT can be used to detect macroscopic fat based on Hounsfield attenuation. This case describes a case of macroscopic fat embolism to the pulmonary arteries which was confidently diagnosed at CTPA. Distinction from thromboembolism is important as treatment is supportive and may avoid risks of anticoagulation.
The importance of lung cancer as a complication of lung transplantation is increasingly recognised. It may become an important survival-limiting factor in lung transplant patients as management of other complications continues to improve and utilisation of extended criteria donors grows. Radiology can play a key role in tackling this issue at multiple stages in the transplantation pathway and follow-up process. Routine chest CT as part of pre-transplant recipient assessment (and donor assessment if available) can identify suspicious lung lesions with high sensitivity and detect chronic structural lung diseases such as pulmonary fibrosis associated with an increased risk of malignancy post-transplant. Pre-transplant CT also provides a comparison for later CT studies in the assessment of nodules or masses. The potential role of regular chest CT for lung cancer screening after transplantation is less certain due to limited available evidence on its efficacy. Radiologists should be cognisant of how the causes of pulmonary nodules in lung transplant patients may differ from the general population, vary with time since transplantation and require specific recommendations for further investigation/follow-up as general guidelines are not applicable. As part of the multidisciplinary team, radiology is involved in an aggressive diagnostic and therapeutic management approach for nodular lung lesions after transplant both through follow-up imaging and image-guided tissue sampling. This review provides a comprehensive overview of available clinical data and evidence on lung cancer in lung transplant recipients, and in particular an assessment of the current and potential roles of pre- and post-transplant imaging. KEY POINTS: • Lung cancer after lung transplantation may become an increasingly important survival-limiting factor as mortality from other complications declines. • There are a number of important roles for radiology in tackling the issue which include pre-transplant CT and supporting an aggressive multidisciplinary management strategy where lung nodules are detected in transplant patients. • The introduction of routine surveillance chest CT after transplant in addition to standard clinical follow-up as a means of lung cancer screening should be considered.
Objective: Sequential posteroanterior chest radiographs (CXRs) on any one patient are commonly displayed at different sizes on PACS monitors. The purpose of this study was to determine the cause of these differences, the percentage of radiographs affected, the relative change in magnification seen and if radiologists were aware of this display difference. Methods: Differences in routine radiographer collimation pre-acquisition and image cropping (shuttering) post acquisition were noted. From three different hospitals, 300 posteroanterior (PA) erect CXRs with prior comparative studies were viewed side-by-side on a standard landscape display monitor. Variation in display size was calculated using the number of detector elements in the autofitted axis of the radiograph, when compared with the prior study. Correlation between patient gender and extent of magnification between images was recorded. Following this, a national survey was circulated to see if radiologists were aware of this phenomenon. Results: Large variations in display size were noted. The mean extent of magnification between sequential PA chest radiographs was +/- 6.8% (range 0-21.6%). 98% of CXRs had some degree of variability in display size. There was no significant difference in the extent of variation in magnification based on age or gender. 86% of the radiologists who responded to the survey (n = 132) were unaware of any display size variability. Conclusion: Sequential DR acquired chest radiographs are routinely displayed with varying degrees of magnifi-cation on PACS monitors due to differences in radiographer practice and auto-fit display settings. Most radiol-ogists surveyed were unaware of these differences and their causation.
Transrectal ultrasound-guided (TRUS) biopsy of the prostate is associated with increased risk of post-procedural sepsis with associated morbidity, mortality, re-admission to hospital, and increased healthcare costs. In the study institution, active surveillance of post-procedural infection complications is performed by clinical nurse specialists for prostate cancer under the guidance of the infection prevention and control team. To protect hospital services for acute medical admissions related to the coronavirus disease 2019 (COVID-19) pandemic, TRUS biopsy services were reduced nationally, with exceptions only for those patients at high risk of prostate cancer. In the study institution, this change prompted a complete move to transperineal (TP) prostate biopsy performed in outpatients under local anaesthetic. TP biopsies eliminated the risk of post-procedural sepsis and, consequently, sepsis-related admission while maintaining a service for prostate cancer diagnosis during the COVID-19 pandemic.
INTRODUCTION:Cardiac implantable electronic devices (CIEDs) are increasing in prevalence. Exposing patients with CIEDs to magnetic resonance imaging (MRI) can lead to adverse outcomes. This has led certain radiology departments to not accept MRI referrals related to patients with CIEDs. Patients with MR-conditional CIEDs can be safely scanned under specific conditions. Our institution has accepted such referrals since 2014. The aim of this study was to systematically identify and reduce risk in our CIED-MRI protocol using failure mode and effects analysis (FMEA).METHODS:A multidisciplinary FMEA team was assembled and included senior stakeholders from the CIED-MRI protocol. A process map was constructed followed by risk analysis and scoring. Targeted interventions were formulated and implemented; high-risk failure modes were prioritized. A new process map and protocol were drafted and repeat risk analysis was performed. Monitoring and re-evaluation of the CIED-MRI pathway were instigated at departmental quality assurance (QA) meetings.RESULTS:Interventions included direct CIED characterization using wireless technology pre-MRI, CIED programming and reprogramming in the MRI suite before and immediately after MRI reducing device downtime and continuous patient monitoring during MRI by a cardiac physiologist. The cumulative risk priority number (RPN) decreased from 1190 pre-FMEA to 492 post-FMEA.DISCUSSION:Despite the risk of exposing CIEDs to the MR environment, patients with MR-conditional CIEDs can be safely scanned with an appropriate multidisciplinary support. We found FMEA an indispensable tool in identifying and minimizing risk with no adverse events recorded since FMEA recommendations were implemented.
•Respirators used for COVID-19 protection have not been tested for MR safety.•Three of four respirators tested contained ferromagnetic components.•These respirators are ‘MR unsafe’.•Respirators used for COVID-19 protection should be reviewed locally for MR safety.•Surgical masks offer a WHO approved safe alternative for MR staff.
AIM: To review contrast medium administration protocols used for cardiothoracic applications of time-resolved, contrast-enhanced magnetic resonance angiography (MRA) sequences. MATERIALS AND METHODS: A systematic search of the literature (Medline/EMBASE) was performed to identify articles utilising time-resolved MRA sequences, focusing on type of sequence, adopted technical parameters, contrast agent (CA) issues, and acquisition workflow. Study design, year of publication, population, magnetic field strength, type, dose, and injection parameters of CA, as well as technical parameters of time-resolved MRA sequences were extracted. RESULTS: Of 117 retrieved articles, 16 matched the inclusion criteria. The study design was prospective in 9/16 (56%) articles, and study population ranged from 5 to 185 patients, for a total of 506 patients who underwent cardiothoracic time-resolved MRA. Magnetic field strength was 1.5 T in 13/16 (81%), and 3 T in 3/16 (19%) articles. The administered CA was gadobutrol (Gadovist) in 6/16 (37%) articles, gadopentetate dimeglumine (Magnevist) in 5/16 (31%), gadobenate dimeglumine (MultiHance) in 2/16 (13%), gadodiamide (Omniscan) in 2/16 (13%), gadofosveset trisodium (Ablavar, previously Vasovist) in 1/16 (6%). CA showed highly variable doses among studies: fixed amount or based on patient body weight (0.02-0.2 mmol/kg) and was injected with a flow rate ranging 1-5 ml/s. Sequences were TWIST in 13/16 (81%), TRICKS in 2/16 (13%), and CENTRA 1/16 articles (6%). CONCLUSION: Time-resolved MRA sequences were adopted in different clinical settings with a large spectrum of technical approaches, mostly in association with different CA dose, type, and injection method. Further studies in relation to specific clinical indications are warranted to provide a common standardised acquisition protocol. (C) 2020 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.
To describe a novel time-resolved magnetic resonance angiography (TR-MRA) postprocessing technique using the time-resolved angiography with interleaved stochastic trajectories (TWIST) method to evaluate the pulmonary veins and left atrium in adults with congenital heart disease undergoing cardiac MRI. Institutional ethics committee approved the study. 21 consecutive adult patients (14 female, 7 male patients, mean age 28 years) with known congenital heart disease who underwent a cardiac MRI were included. Post-processing of the TR-MRA sequences created novel “subtracted” datasets. Two independent observers reviewed the conventional TWIST and novel subtracted TWIST data sets in source and maximum intensity projection (MIP) coronal reformats to assess visualization of the pulmonary veins and left atrium based on a 5-point scale. Quantitative signal to noise (SNR) comparison was performed. TR-MRA yielded diagnostic image data in 20/21 patients (95.2%). The novel “subtracted” TR-MRA technique improved visualization of the pulmonary veins and left atrium compared to the source TR-MRA sequence in 16/20 patients (mean scores 3.34 ± 0.69 vs. 2.92 ± 0.69, p < 0.008). Further improved visualization of the pulmonary veins and left atrium was observed in the subtracted MIP TWIST sequences compared to the MIP TWIST images (mean scores 4.43 ± 0.80 vs. 3.02 ± 0.87 vs., p < 0.001). No significant SNR difference between the source and novel subtracted group was observed (85.4 vs. 70.4, p = 0.57). Compared to source TR-MRA images, subtraction of TR-MRA images is a novel postprocessing technique that improves visualization of the pulmonary veins and left atrium in a substantial number of patients.
Patients with cardiac implantable electronic devices (CIEDs) were traditionally denied access to MR imaging due to safety concerns.
Clinically evident arterial thrombosis is rare following thrombin injection therapy for femoral pseudoaneurysm. However, it is unclear to what extent injected thrombin may pass to the ipsilateral lower limb arteries. To assess if technetium 99m injected at the time of thrombin injection for femoral artery pseudoaneurysm therapy passes into the adjacent lower limb arteries. This was a prospective trial with institutional review board approval. Four consecutive patients with common femoral pseudoaneurysms and failed manual compression were enrolled. Under real-time colour flow doppler ultrasound, a mixture of 1000 IU thrombin and approximately 200 MBq technetium 99m was injected in 0.1-mL doses into the pseudoaneurysm until thrombosis occurred. Gamma camera imaging of the syringe before injection, the injected groin after thrombosis and the syringe after injection were performed. Analysis of the gamma camera information was performed to determine the amount of technetium 99m deposited in the arterial tree. All the procedures were technically successful. A mean of 33% (range 3–50%; SD 21) of the administered technetium 99m dose was deposited in the arterial circulation during pseudoaneurysm therapy. No clinically evident arterial thrombosis was identified. Technetium 99m is routinely deposited in the arterial circulation following injection of a mixture of thrombin and technetium for therapy of common femoral artery pseudoaneurysms. This suggests that arterial passage of thrombin is more common than clinically evident.
Poster: ECR 2019 / C-1280 / The use of Siemens teamplay™ in establishing cardiac CT diagnostic reference levels by: S. Maguire 1, P. Gilligan1, B. M. L. McCoubrey1, M. Smyth2, S. J. Eustace3, J. G. Murray1; 1Dublin/IE, 2Dublin 7/IE, 3Dublin 4/IE
BACKGROUND:The presence of a structural cardiac defect in the setting of dextrocardia is extremely rare. Graspable models allow enhanced appreciation of aberrant structures and vascular relations, particularly in rare and complex cases. This is the first case report of the use of a replica of a patients' anatomy to plan the surgical strategy in the setting of dextrocardia.AIMS:We intend to demonstrate the benefit of three-dimensional printing to enhance preoperative planning in complex congenital heart disease undergoing heart transplantation. The anomalous structures encountered include situs inversus dextrocardia, transposition of the great vessels, a single atrium and a dilated double-outlet single right ventricle.METHODS:Computed Tomography acquisition was performed with the use of ECG multiphase gating technology and contrast enhancement. The structures of interest were segmented and the generated 3D mesh was exported as a stereolithographic (STL) file. The model was printed on a Z-Corp 250 binder jetting printer. Post processing techniques were used to enhance model strength.RESULTS:Pre-operative 3D visualisation of the patients' anatomy allowed for a more comprehensive surgical strategy to be planned, thus reducing the intra-operative duration and cross-clamp time which are recognised to correlate with reduced patient morbidity.CONCLUSION:The ongoing advances in medical image procurement and 3D processing software and printing technology will continue to enhance preoperative planning and thereby improve patient care. We demonstrate the pivotal role played by such technologies in advancing spatial comprehension of complex aberrant anatomy.
Purpose: Three-dimensional (3D) printing, also known as ‘additive manufacturing’ is a process which generates
Purpose: The study sought to determine the frequency of nonthromboembolic imaging abnormalities in pregnant women referred for computed tomography pulmonary arteriography (CTPA).Materials and Methods: CTPA studies on 100 consecutive pregnant women performed over a 5-year period were reviewed independently by 2 radiologists, with conflicts resolved by consensus. Age range was 18-43 years (mean 28 years). The presence or absence of pulmonary embolism and of nonthromboembolic imaging abnormalities was recorded. These were graded as A if the abnormalities were thought to provide potential alternative explanations for acute symptoms, B if findings were incidental that required clinical or radiologic follow-up, and C if the findings did not require further action.Results: Pulmonary embolism was seen in 5 women. In 2 of these additional findings of consolidation and infarction were seen. Ninety-five women did not have pulmonary embolism. Eleven women (12%) had grade A abnormalities; 6 cases of consolidation, 2 cases of lobar collapse, and 3 cases of heart failure with pleural effusions. One woman had a grade B abnormality due to the presence of pulmonary nodules. Ten women had incidental grade C abnormalities.Conclusion: Pulmonary embolism occurs in 5% of pregnant women referred for CTPA. In pregnant women without embolism on CTPA, potential alternative causes for patient symptoms are seen on CT in 12% of cases.
Pulmonary complications in rheumatoid arthritis (RA) are well documented in the literature and include pleural disease, pulmonary infection, pneumonitis, bronchiolitis obliterans, bronchiectasis, interstitial lung disease, and bronchogenic carcinoma. Rheumatoid pulmonary nodules are uncommon, affecting < 5% of patients with RA, and are more common in men1. They may be solitary or multiple, and are usually located peripherally in the subpleural space. Cavitation is estimated to occur in < 50% of patients, less commonly than with granulomatosis with polyangiitis (Wegener’s)-related pulmonary nodules2. Spontaneous pneumothoraxes complicating …
Introduction: Patients with end‐stage emphysema because of α‐1 antitrypsin (AAT) deficiency represent a challenging clinical management problem, and studies of volume reduction therapy to date have largely excluded these patients. We report the outcome of bronchoscopic volume reduction with the insertion of Emphasys endobronchial valves (Emphasys Medical, Redwood City, CA, USA) in six patients with end‐stage emphysema because of AAT deficiency.
Objective: To examine the use of the modified Wells score in pregnancy as a risk stratification tool in the diagnosis of pulmonary embolism (PE). Methods: All pregnant or post-partum patients who were referred for CT Pulmonary Angiography (CTPA) to evaluate suspected PE over a 5-year period were included in the study. Patient records were used to apply the modified Wells score (MWS) and analyze their risk of PE. Results: A total of 125 women were referred for CTPA over 5 years. A MWS of 6 or greater (“High Risk”) was 100% sensitive and 90% specific with a positive predictive value of 36% for PE on CTPA. No patients with a low MWS (less than 6) had a PE, giving a negative predictive value of 100%. p ≤ 0.001. D-dimers, chest X-ray, blood gases and EKG were significantly less effective than the MWS in aiding the diagnosis of PE. Conclusion: Current methods employed for the diagnosis of PE are inadequate. Risk stratification using the MWS may allow safe exclusion of PE before resorting to CTPA. To the best of our knowledge this is the first study to have used the MWS in a pregnant patient group.
Percutaneous pulmonary venous atrial puncture was performed under computed tomography guidance to successfully place an automated implantable cardiac defibrillator into a 26-year-old patient with extracardiac Fontan conduit who had presented with two out-of-hospital cardiac arrests. The procedure avoided the need for lead placement at thoracotomy.