We are studying the implementation of polar direct drive (PDD) ignition experiments on the National Ignition Facility (NIF) laser system. Part of this preparation involves testing the performance of the NIF laser system over a broader span of center wavelengths, 3.6 nm, where the laser currently operates and that gain models describe. The temporal shape for the PDD pulses consists of a drive pulse preceded by three lower power “picket pulses”. These picket pulses require a multi-FM sinusoidal phase modulation format with a bandwidth of ∼ 200 GHz and a more dispersive grating in the preamplifier module (PAM) for smoothing-by-spectral-dispersion (SSD). In this paper we discuss recent measurements of gain on the NIF laser system over this broader wavelength range. We measured FM-to-AM conversion over the 3.6 nm wavelength range. The possibility of pinhole closure due to the larger bandwidth and dispersion associated with multi-FM SSD was studied at LLE on the OMEGA EP laser.
The National Ignition Facility (NIF) at Lawrence Livermore National Laboratory is the first of a kind megajoule-class laser with 192 beams capable of delivering over 1.8 MJ and 500TW of 351nm light [1], [2]. It has been commissioned and operated since 2009 to support a wide range of missions including the study of inertial confinement fusion, high energy density physics, material science, and laboratory astrophysics.In order to advance our understanding, and enable short-pulse multi-frame radiographic experiments of dense cores of cold material, the generation of very hard x-rays above 50 keV is necessary. X-rays with such characteristics can be efficiently generated with high intensity laser pulses above 10(17) W/cm(2) [3]. The Advanced Radiographic Capability (ARC) [4] which is currently being commissioned on the NIF will provide eight, 1 ps to 50 ps, adjustable pulses with up to 1.7 kJ each to create x-ray point sources enabling dynamic, multi-frame x-ray backlighting.This paper will provide an overview of the ARC system and report on the laser performance tests conducted with a stretched-pulse up to the main laser output and their comparison with the results of our laser propagation codes.
We have measured the temporal contrast and performance of oscillators to determine their feasibility for future ultra-high-contrast experiments on the Advanced Radiographic Capability at the National Ignition Facility.
In order to achieve the highest intensities possible with the short-pulse Advanced Radiographic Capability beamline at the National Ignition Facility (NIF), it will be necessary to phase the individual ARC apertures. This is made especially challenging because the design of ARC results in two laser beams with different dispersions sharing the same NIF aperture. The extent to which two beams with different dispersions can be phased with each other has been an open question. This paper presents results of an analysis showing that the different dispersion values that will be encountered by the shared-aperture beams will not preclude the phasing of the two beams. We also highlight a situation in which dispersion mismatch will prevent good phasing between apertures, and discuss the limits to which higher-order dispersion values may differ before the beams begin to dephase.
We are converting a quad of NIF beamlines into eight, short-pulse (1–50 ps), petawatt-class beams for advanced radiography and fast ignition experiments. This paper describes progress toward completing this project.
We have characterized the Advanced Radiographic Capability injection laser system and demonstrated that it meets performance requirements for upcoming National Ignition Facility fusion experiments. Pulse compression was achieved with a scaled down replica of the meter-scale grating ARC compressor and sub-ps pulse duration was demonstrated at the Joule-level.
The phase-shift technique for measuring group-delay has novel applications for aligning and commissioning grating compressors and balancing dispersion in large, high-energy petawatt and other complex, chirped-pulse amplifier systems.
We present the status of plans to commission a short-pulse, quad of beams on the National Ignition Facility (NIF), capable of generating > 10 kJ of energy in 10 ps. These beams will initially provide an advanced radiographic capability (ARC) to generate brilliant, x-ray back-lighters for diagnosing fuel density and symmetry during ignition experiments. A fiber, mode-locked oscillator generates the seed pulse for the ARC beam line in the NIF master oscillator room (MOR). The 200 fs, 1053 nm oscillator pulse is amplified and stretched in time using a chirped-fiber-Bragg grating. The stretched pulse is split to follow two separate beam paths through the chain. Each pulse goes to separate pulse tweakers where the dispersion can be adjusted to generate a range of pulse widths and delays at the compressor output. After further fiber amplification the two pulses are transported to the NIF preamplifier area and spatially combined using shaping masks to form a split-spatial-beam profile that fits in a single NIF aperture. This split beam propagates through a typical NIF chain where the energy is amplified to several kilojoules. A series of mirrors directs the amplified, split beam to a folded grating compressor that is located near the equatormore » of the NIF target chamber. Figure 1 shows a layout of the beam transport and folded compressor, showing the split beam spatial profile. The folder compressor contains four pairs of large, multi-layer-dielectric gratings; each grating in a pair accepts half of the split beam. The compressed output pulse can be 0.7-50 ps in duration, depending on the setting of the pulse tweaker in the MOR. The compressor output is directed to target chamber center using four additional mirrors that include a 9 meter, off-axis parabola. The final optic, immediately following the parabola, is a pair of independently adjustable mirrors that can direct the pair of ARC beams to individual x-ray backlighter targets. The first mirror after the compressor leaks a small fraction of the light that is transported to a diagnostics station where detailed measurements of the spatial and temporal characteristics of the ARC pulse will be recorded for each shot. A NIF quad of short-pulse beams will support up to eight, independently-timed, short-pulse beams, capable of producing an x-ray motion picture. Alternatively, the combined aperture of the quad can direct > 10 kJ of energy in 10 psec onto a single target, enabling research into fast ignition and high-energy-density science on the NIF. We will discuss modifications to the NIF to accommodate ARC, including features such as simultaneous NIF-ARC operation in the same NIF quad, protection against backward propagating pulses from the target and plans to coherently add split beams.« less
We are developing a fiber laser front end suitable for high energy petawatt laser systems on large glass lasers such as NIF. The front end includes generation of the pulses in a fiber mode-locked oscillator, amplification and pulse cleaning, stretching of the pulses to >3ns, dispersion trimming, timing, fiber transport of the pulses to the main laser bay and amplification of the pulses to an injection energy of 150 {micro}J. We will discuss current status of our work including data from packaged components. Design detail such as how the system addresses pulse contrast, dispersion trimming and pulse width adjustment and impact of B-integral on the pulse amplification will be discussed. A schematic of the fiber laser system we are constructing is shown in figure 1 below. A 40MHz packaged mode-locked fiber oscillator produces {approx}1nJ pulses which are phase locked to a 10MHz reference clock. These pulses are down selected to 100kHz and then amplified while still compressed. The amplified compressed pulses are sent through a non-linear polarization rotation based pulse cleaner to remove background amplified spontaneous emission (ASE). The pulses are then stretched by a chirped fiber Bragg grating (CFBG) and then sent through a splitter. The splitter splits the signal into two beams. (From this point we follow only one beam as the other follows an identical path.) The pulses are sent through a pulse tweaker that trims dispersion imbalances between the final large optics compressor and the CFBG. The pulse tweaker also permits the dispersion of the system to be adjusted for the purpose of controlling the final pulse width. Fine scale timing between the two beam lines can also be adjusted in the tweaker. A large mode area photonic crystal single polarization fiber is used to transport the pulses from the master oscillator room to the main laser bay. The pulses are then amplified a two stage fiber amplifier to 150mJ. These pulses are then launched into the main amplifier chain. We are currently constructing a packaged prototype of this system, which will ultimately be deployed on the National Ignition Facility (NIF). In our talk we will discuss the packaged components as well as the numerous technical challenges that needed to be overcome in order to make this system possible. Of particular interest was the quality of recompressed pulses that could be achieved with a CFBG. We will show background free auto-correlation data from pulses with a dynamic range noise limited to six orders of magnitude that were stretched with a CFBG and then recompressed in a standard compressor (figure 2). We will also discuss in detail the impact of B-integral accumulation on the recompressed pulses. Our current system is projected to run at an accumulated B-integral of 7. However, because our injected system bandwidth is much wider than the NIF system bandwidth our system can tolerate this high B-integral.
The Picosecond Laser-Electron Interaction for the Dynamic Evaluation of Structures (PLEIADES) facility provides tunable short x-ray pulses with energies of 30-140 keV and pulse durations of 0.3 – 5 ps by scattering an intense, ultrashort laser pulse off a 35-75 MeV electron beam. Synchronization of the laser and electron beam is obtained by using a photoinjector gun, and using the same laser system to generate the electrons and the scattering laser. The Ti: Sapphire, chirped pulse amplification based 500 mJ, 50 fs, 810 nm scattering laser and the similar 300 μJ, 5 ps, 266 nm photoinjector laser systems are detailed. Additionally, an optical parametric chirped pulse amplification (OPCPA) system is studied as a replacement for part of the scattering laser front end. Such a change would significantly simplify the set-up the laser system by removing the need for active switching optics, as well as increase the pre-pulse contrast ratio which will be important when part of the scattering laser is used as a pump beam in pump-probe diffraction experiments using the ultrashort tunable x-rays generated as the probe.
An ultra fast, sub-picosecond resolution streak camera has been recently developed at the LLNL. The camera is a versatile instrument with a wide operating wavelength range. The temporal resolution of up to 300 fs can be achieved, with routine operation at 500 fs. The streak camera has been operated in a wide wavelength range from IR to x-rays up to 2 keV. In this paper we briefly review the main design features that result in the unique properties of the streak camera and present its several scientific applications: (1) Streak camera characterization using a Michelson interferometer in visible range, (2) temporally resolved study of a transient x-ray laser at 14.7 nm, which enabled us to vary the x-ray laser pulse duration from ~2-6 ps by changing the pump laser parameters, and (3) an example of a time-resolved spectroscopy experiment with the streak camera.
The PLEIADES (Picosecond Laser-Electron Inter-Action for the Dynamical Evaluation of Structures) facility has produced first light at 70 keV. This milestone offers a new opportunity to develop laser-driven, compact, tunable x-ray sources for critical applications such as diagnostics for the National Ignition Facility and time-resolved material studies. The electron beam was focused to 50 μm rms, at 57 MeV, with 260 pC of charge, a relative energy spread of 0.2%, and a normalized emittance of 5 mm mrad horizontally and 13 mm mrad vertically. The scattered 820 nm laser pulse had an energy of 180 mJ and a duration of 54 fs. Initial x rays were captured with a cooled charge-coupled device using a cesium iodide scintillator; the peak photon energy was approximately 78 keV, with a total x-ray flux of 1.3×106 photons/shot, and the observed angular distribution found to agree very well with three-dimensional codes. Simple K-edge radiography of a tantalum foil showed good agreement with the theoretical divergence-angle dependence of the x-ray energy. Optimization of the x-ray dose is currently under way, with the goal of reaching 108 photons/shot and a peak brightness approaching 1020 photons/mm2/mrad2/s/0.1% bandwidth.
High average-power free-electron lasers may be useful for pumping high peak-power solid-state laser-amplifiers. At very high peak-powers, the pump source for solid-state lasers is non-trivial: flash lamps produce thermal problems and are unsuitable for materials with short florescence-times, while diodes can be expensive and are only available at select wavelengths. FELs can provide pulse trains of light tuned to a laser material's absorption peak, and florescence lifetime. An FEL pump can thus minimize thermal effects and potentially allow for new laser materials to be used. This paper examines the design of a high average-power, efficient high-gain FEL for use as pump source. Specifically, the cases of a 100 J class pump, and a 100 TW-class laser at a planned fourth-generation light-source are considered.
The Compton scattering of a terawatt-class, femtosecond laser pulse by a high-brightness, relativistic electron beam has been demonstrated as a viable approach toward compact, tunable sources of bright, fermosecond, hard X-ray flashes. The main focus of this article is a detailed description of such a novel X-ray source, namely the PLEIADES (Picosecond Laser-Electron Inter-Action for the Dynamical Evaluation of Structures) facility at Lawrence Livermore National Laboratory. PLEIADES has produced first light at 70 keV, thus enabling critical applications, such as advanced backlighting for the National Ignition Facility and in situ time-resolved studies of high-Z materials. To date, the electron beam has been focused down to sigma(x) = sigma(y) = 27 mum rms, at 57 MeV, with 266 pC of charge, a relative energy spread of 0.2%, a normalized horizontal' emittance of 3.5 mm (.) mrad, a normalized vertical emittance of I I mm (.) mrad, and a duration of 3 ps rms. The compressed laser pulse energy at focus is 480 mJ, the pulse duration 54 fs Intensity Full Width at Half-Maximum (IFWHM), and the 1/e(2) radius 36 mum. Initial X rays produced by head-on collisions between the laser and electron beams at a repetition rate of 10 Hz were captured with a cooled CCD using a CsI scintillator; the peak photon energy was approximately 78 keV, and the observed angular distribution was found to agree very well with three-dimensional codes. The current X-ray dose is 3 X 106 photons per pulse, and the inferred peak brightness exceeds 10(15) photons/ (mm(2) X mrad(2) X s X 0. 1% bandwidth). Spectral measurements using calibrated foils of variable thickness are consistent with theory. Measurements of the X-ray dose as a function of the delay between the laser and electron beams show a 24-ps full width at half maximum (FWHM) window, as predicted by theory, in contrast with a measured timing jitter of 1.2 ps, which contributes to the stability of the source. In addition, K-edge radiographs of a Ta foil obtained at different electron beam energies clearly demonstrate the gamma(2)-tunability of the source and show very good agreement with the theoretical divergence-angle dependence of the X-ray spectrum. Finally, electron bunch shortening experiments using velocity compression have also been performed and durations as short as 300 A rms have been observed using coherent transition radiation; the corresponding inferred peak X-ray flux approaches 10(19) photons/s.
Remarkable developments in critical technologies including terawatt-class lasers using chirped-pulse amplification, high brightness photoinjectors, high-gradient accelerators, and superconducting linacs make it possible to design and operate compact, tunable, subpicosecond Compton scattering x-ray sources with a wide variety of applications. In such novel radiation sources, the collision between a ferntosecond laser pulse and a low emittance relativistic electron bunch in a small (mu m(3)) interaction volume produces Doppler-upshifted scattered photons with unique characteristics: the energy is tunable in the 5-500 keV range, the angular divergence of the beam is small (mrad), and the pulses are ultrashort (10 fs - 10 ps). Two main paths are currently being followed in laboratories worldwide: high peak brightness, using ultrahigh intensity ferntosecond lasers at modest repetition rates, and high average brightness, using superconducting linac and high average power laser technology at MHz repetition rates.Targeted applications range from x-ray protein crystallography and high contrast medical imaging to ferntosecond pump-probe and diffraction experiments. More exotic uses of such sources include the gamma-gamma collider, NIF backlighting, nonlinear Compton scattering, and high-field QED. Theoretical considerations and experimental results will be discussed within this context.
PLEIADES is a compact, tunable, high-brightness, ultra-short-pulse, Thomson-scattering X-ray source. Picosecond pulses of hard X-rays (10–200 keV) are created by colliding an ultra-relativistic (20–100 MeV), picosecond-duration electron beam with a high-intensity, sub-picosecond, 800-nm laser pulse. Initial operation of this source has produced 78-keV X-rays with 10 6 photons per pulse using a 57-MeV, 0.3-nC, 50-μm rms width electron beam and a 180-mJ, 15-μm rms width laser pulse. The angular distribution, energy, and energy spectrum of the source are found to agree well with theory and simulations. Source optimization is expected to increase X-ray output to between 10 7 and 10 8 photons per pulse with a peak brightness approaching 10 20 photons/s/0.1% bandwidth/mm 2 /mrad 2 .
We present a detailed comparison of the measured characteristics of Thomson backscattered x rays produced at the Picosecond Laser-Electron Interaction for the Dynamic Evaluation of Structures facility at Lawrence Livermore National Laboratory to predicted results from a newly developed, fully three-dimensional time and frequency-domain code. Based on the relativistic differential cross section, this code has the capability to calculate time and space dependent spectra of the x-ray photons produced from linear Thomson scattering for both bandwidth-limited and chirped incident laser pulses. Spectral broadening of the scattered x-ray pulse resulting from the incident laser bandwidth, perpendicular wave vector components in the laser focus, and the transverse and longitudinal phase spaces of the electron beam are included. Electron beam energy, energy spread, and transverse phase space measurements of the electron beam at the interaction point are presented, and the corresponding predicted x-ray characteristics are determined. In addition, time-integrated measurements of the x rays produced from the interaction are presented and shown to agree well with the simulations.
The use of short laser pulses to generate high peak intensity, ultra-short x-ray pulses enables exciting new experimental capabilities, such as femtosecond pump-probe experiments used to temporally resolve material structural dynamics on atomic time scales. PLEIADES (Picosecond Laser Electron InterAction for the Dynamic Evaluation of Structures) is a next generation Thomson scattering x-ray source being developed at Lawrence Livermore National Laboratory (LLNL). Ultra-fast picosecond x-rays (10-200 keV) are generated by colliding an energetic electron beam (20-100 MeV) with a high intensity, sub-ps, 800 nm laser pulse. The peak brightness of the source is expected to exceed 10/sup 20/ photons/s/0.1% bandwidth/nm/sup 2//mrad/sup 2/. Simulations of the electron beam production, transport, and final focus are presented. Electron beam measurements, including emittance and final focus spot size are also presented and compared to simulation results. Measurements of x-ray production are also reported and compared to theoretical calculations.