Inactivation of collected viral aerosols is important for preventing a filter medium’s serving as a fomite. The focus of this study was to evaluate the inactivation efficiency (IE) achieved through filtration coupled with microwave irradiation. MS2 aerosolized through a Collison nebulizer was fed into the system and collected onto the filter. For in-flight microwave decontamination, microwave irradiation was applied to an HVAC (heating, ventilation and air conditioning) filter supported on a SiC disk for three cycles of selected irradiation times per 10 min (i.e., 1, 2.5, 5, and 10 min/10 min) at power levels ranging from 125 W to 375 W. The survival fraction (SF) on the substrate and the IE through the entire system were investigated to determine the efficacy of this approach. SF decreased and IE increased as microwave power level was increased (p = 0.02 and p < 0.01, respectively) or the application time was extended (p = 0.03 and p < 0.01, respectively). Both measures changed sharply above a threshold temperature of around 90°C and reached 2 logs at 116 and 109°C, respectively. The log SF and IE of –2.59 and 3.62, respectively, were observed when the operating condition of 375 W for 10 min/cycle was used and the SiC disk facilitated microwave absorption. When a quartz frit was used as a support instead of the SiC disk, log inactivation efficiencies of 0.8, 1.0, and 1.3 were measured at relative humidities of 30
Nosocomial infections pose an escalating threat to both patients and healthcare workers (HCWs). A widely recommended device for individual respiratory protection, the N95 filtering facepiece respirator (FFR) has been shown to provide efficient filtration of inert particles larger and smaller than the nominal most-penetrating particle size (MPPS) range, 0.03-0.3 μm. Humans generate respiratory aerosols in the MPPS range, suggesting that short-range disease transmission could occur via small infectious particles. Data presented here show that the N95 FFR will afford a significant measure of protection against infectious particles as small as a bare H1N1 influenza virion, and that the capture mechanism does not discriminate in favor of, or against, biological particles.
Nosocomial infections pose a significant and escalating threat to both patients and healthcare workers (HCWs). By their nature, hospitals induce antibiotic resistance in virulent and commensal strains, leading to increasingly severe hospital-acquired infections. This study measured environmental exposure experienced by domestic staff cleaning vacated patient rooms of a community hospital to bacteria in ambient bioaerosols. While they cleaned the room, participants wore an N95 filtering facepiece respirator (FFR), from which coupons were cut and bacteria were extracted, cultured and enumerated. Extrapolation to the full area of the respirator yielded measured exposures of 0.2-1.4 × 10(4) colony-forming units/hour, of which ∼97% collected on the front layer of the N95, suggesting a possible role for minimal respiratory protection in nonpatient environments. Random resistance testing of 1.6% of the isolates showed that ∼70% of both Gram-positive and Gram-negative organisms exhibited resistance to oxacillin and ∼9% of the Gram-positives displayed resistance to vancomycin. These data provide an estimate for mask bioaerosol loading that can be used in risk modeling and to refine strategies for reuse of FFRs during critical shortages.
This study assessed the correlation of N95 filtering facepiece respirator (FFR) fit between a Static Advanced Headform (StAH) and 10 human test subjects. Quantitative fit evaluations were performed on test subjects who made three visits to the laboratory. On each visit, one fit evaluation was performed on eight different FFRs of various model/size variations. Additionally, subject breathing patterns were recorded. Each fit evaluation comprised three two-minute exercises: “Normal Breathing,” “Deep Breathing,” and again “Normal Breathing.” The overall test fit factors (FF) for human tests were recorded. The same respirator samples were later mounted on the StAH and the overall test manikin fit factors (MFF) were assessed utilizing the recorded human breathing patterns. Linear regression was performed on the mean log10-transformed FF and MFF values to assess the relationship between the values obtained from humans and the StAH.This is the first study to report a positive correlation of respirator fit between a headform and test subjects. The linear regression by respirator resulted in R2 = 0.95, indicating a strong linear correlation between FF and MFF. For all respirators the geometric mean (GM) FF values were consistently higher than those of the GM MFF. For 50% of respirators, GM FF and GM MFF values were significantly different between humans and the StAH. For data grouped by subject/respirator combinations, the linear regression resulted in R2 = 0.49. A weaker correlation (R2 = 0.11) was found using only data paired by subject/respirator combination where both the test subject and StAH had passed a real-time leak check before performing the fit evaluation. For six respirators, the difference in passing rates between the StAH and humans was < 20%, while two respirators showed a difference of 29% and 43%. For data by test subject, GM FF and GM MFF values were significantly different for 40% of the subjects. Overall, the advanced headform system has potential for assessing fit for some N95 FFR model/sizes.
The performance of a Collison nebulizer delivering viable H1N1 influenza aerosols was assessed in terms of particle size distribution (PSD) and survivability of the virus upon generation. An H1N1 influenza virus preparation in egg allantoic fluid was diluted in sterile deionized water to a concentration of 3.4 x 10(6) TCID50/mL. The virus suspension was aerosolized at air flow rates of 2, 6 and 12 L/min using a 1-jet, 3-jet and 6-jet Collison nebulizer, respectively. A scanning mobility particle sizer measured the PSD of the viral aerosol after steady-state delivery times of 1, 15, 30, 45 and 60 min. After 60 min of continuous aerosolization, the viral titre was unchanged and the count median diameter (CMD) of the aerosol PSD was approximate to 38 nm for the 2 L/min flow rate, approximate to 35 nm for the 6 L/min flow rate and approximate to 33 nm for the 12 L/min flow rate. The CMDs were much smaller than the influenza virus (80-120 nm), indicating the aerosol distribution comprised mainly nonviable materials. The PSD produced by the Collison nebulizer exhibited a 20% increase in peak particle concentration after 60 min of continuous operation at 12 L/min. This progressive increase in particle counts may be attributed to a combination of evaporation and shear and impact stresses imparted on components by the Collison nebulizer. The possible slight loss in H1N1 influenza viability over the course of 60 min of continuous aerosolization at 12 L/min is consistent with previous bioaerosol studies using a Collison nebulizer.
The zero-volume airlock concept minimizes the volume of air in and transiting through the airlock by effusing air from the clean area through spaces between deformable air bladders. An individual transiting through the airlock into a shelter displaces the bladders and creates ephemeral regions of varying dimensions and air velocities, which affect deposition and reaerosolization of particles. Properties of the aerosols and bladder surfaces are also influences, so the airlock may be treated to shed or retain particles and possibly to promote decontamination of them; the uniform material determines the protection from or exposure to these particles that the wearer experiences. To initiate evolution of a predictive computational model for the deposition and disposition of airborne particles in an airlock, this study presents measurements of deposition rates of Bacillus atrophaeus spores, a common simulant for anthrax spores, on a variety of fabrics as a function of airspeed and angle of incidence at ~22°C and ~55% RH in a laboratory-scale aerosol tunnel. A computational model using inert surface properties consistently underpredicted experimental results by a factor of 2–10, suggesting that the variation in results across the test panel can be exploited to generate empirical parameters that can be substituted into the model to improve its predictive capability. Factors and possible approaches to computational descriptions are considered.
AimsTo avoid interference by water-iodine disinfection chemistry and measure directly the effect of iodine, captured from a triiodide complex bound to a filter medium, on viability of penetrating viral particles.Methods and ResultsAerosols of MS2 coli phage were passed through control P100 or iodinated High-Efficiency Particulate Air media, collected in plastic bags, incubated for 0-10min, collected in an impinger containing thiosulphate to consume all unreacted iodine, plated and enumerated. Comparison of viable counts demonstrated antimicrobial activity with an apparent half-life for devitalization in tens of seconds; rate of kill decreased at low humidity and free iodine was captured by the bags.ConclusionsThe results support the mechanism of near-contact capture earlier proposed; however, the disinfection chemistry in the aerosol phase is very slow on the time scale of inhalation.Significance and Impact of the StudyThis study shows that disinfection by filter-bound iodine in the aerosol phase is too slow to be clinically significant in individual respiratory protection, but that it might be of benefit to limit airborne transmission of infections in enclosed areas.
Improved respirator test headforms are needed to measure the fit of N95 filtering facepiece respirators (FFRs) for protection studies against viable airborne particles. A Static (i.e., non-moving, non-speaking) Advanced Headform (StAH) was developed for evaluating the fit of N95 FFRs. The StAH was developed based on the anthropometric dimensions of a digital headform reported by the National Institute for Occupational Safety and Health (NIOSH) and has a silicone polymer skin with defined local tissue thicknesses. Quantitative fit factor evaluations were performed on seven N95 FFR models of various sizes and designs. Donnings were performed with and without a pre-test leak checking method. For each method, four replicate FFR samples of each of the seven models were tested with two donnings per replicate, resulting in a total of 56 tests per donning method. Each fit factor evaluation was comprised of three 86-sec exercises: "Normal Breathing" (NB, 11.2 liters per min (lpm)), "Deep Breathing" (DB, 20.4 lpm), then NB again. A fit factor for each exercise and an overall test fit factor were obtained. Analysis of variance methods were used to identify statistical differences among fit factors (analyzed as logarithms) for different FFR models, exercises, and testing methods. For each FFR model and for each testing method, the NB and DB fit factor data were not significantly different (P > 0.05). Significant differences were seen in the overall exercise fit factor data for the two donning methods among all FFR models (pooled data) and in the overall exercise fit factor data for the two testing methods within certain models. Utilization of the leak checking method improved the rate of obtaining overall exercise fit factors ≥100. The FFR models, which are expected to achieve overall fit factors ≥ 100 on human subjects, achieved overall exercise fit factors ≥ 100 on the StAH. Further research is needed to evaluate the correlation of FFRs fitted on the StAH to FFRs fitted on people. [Supplementary materials are available for this article. Go to the publisher's online edition of Journal of Occupational and Environmental Hygiene for the following free supplemental resource: a file providing detailed information on the advanced head form design and fabrication process.].
Background: Decontamination, cleaning, and reuse of filtering facepiece respirators (FFRs) has been proposed to mitigate an acute FFR shortage during a public health emergency. Our study evaluates the ability of commercially available wipe products to clean FFRs contaminated with either infectious or noninfectious aerosols.Methods: Three models of surgical N95 FFRs were contaminated with aerosols of mucin or viable Staphylococcus aureus then cleaned with hypochlorite, benzalkonium chloride, or nonantimicrobial wipes. After cleaning, FFRs were separated into components (nose pad, fabrics, and perforated strip), and contaminants were extracted and quantified. Filtration performance was assessed for cleaned FFRs.Results: Mucin removal was <1 log for all wipe products on all components. Inert wipes achieved similar to 1-log attenuation in viable S aureus on fabrics from all FFR models-removal was less effective from nose pads and perforated edges. Both antimicrobial wipes achieved 3-5-log attenuation on most components, with smaller reductions on nose pads and greater reductions on perforated strips. Particle penetration following cleaning yielded mean values <5%. The highest penetrations were observed in FFRs cleaned with benzalkonium chloride wipes.Conclusions: FFRs can be disinfected using antimicrobial wipe products, but not effectively cleaned with the wipes evaluated in this study. This study provides informative data for the development of better FFRs and applicable cleaning products. Copyright (C) 2014 by the Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.
Aims: To evaluate a standard aerosolization method for uniformly depositing threat-representative spores onto surfaces.Methods and Results: Lyophilized Bacillus anthracis Delta Sterne spores, coated in silica, were aerosolized into a containment chamber and deposited onto nine surface types by two independent laboratories. Laboratory A produced a mean loading concentration of 1.78 x 10(5) CFU cm(-2); coefficient of variation (CV) was <40% for 96% of samples. Laboratory B produced a mean loading concentration of 7.82 x 10(6) CFU cm(-2); 68% of samples demonstrated CV <40%.Conclusions: This method has been shown to meet the goal of loading threat-representative spores onto surfaces with low variability at concentrations relevant to the Department of Defense.Significance and Impact of the Study: As demonstrated in 2001, a biological attack using anthrax disseminated as a dry powder is a credible threat. This method will provide a means to load spores onto surfaces that mimic a 'real-world' scenario of an aerosolized anthrax attack. The method has utility for evaluating sporicidal technologies and for nondecontamination studies, for example fate and transport or reaerosolization.
OBJECTIVE. Specification of appropriate personal protective equipment for respiratory protection against influenza is somewhat controversial. In a clinical environment, N95 filtering facepiece respirators (FFRs) are often recommended for respiratory protection against infectious aerosols. This study evaluates the ability of N95 FFRs to capture viable H1N1 influenza aerosols.METHODS. Five N95 FFR models were challenged with aerosolized viable H1N1 influenza and inert polystyrene latex particles at continuous flow rates of 85 and 170 liters per minute. Virus was assayed using Madin-Darby canine kidney cells to determine the median tissue culture infective dose (TCID50). Aerosols were generated using a Collison nebulizer containing H1N1 influenza virus at 1 x 10(8) TCID50/mL. To determine filtration efficiency, viable sampling was performed upstream and downstream of the FFR.RESULTS. N95 FFRs filtered 0.8-mu m particles of both H1N1 influenza and inert origins with more than 95% efficiency. With the exception of 1 model, no statistically significant difference in filtration performance was observed between influenza and inert particles of similar size. Although statistically significant differences were observed for 2 models when comparing the 2 flow rates, the differences have no significance to protection.CONCLUSIONS. This study empirically demonstrates that a National Institute for Occupational Safety and Health-approved N95 FFR captures viable H1N1 influenza aerosols as well as or better than its N95 rating, suggesting that a properly fitted FFR reduces inhalation exposure to airborne influenza virus. This study also provides evidence that filtration efficiency is based primarily on particle size rather than the nature of the particle's origin. Infect Control Hosp Epidemiol 2013;34(5):494-499
ABSTRACT Although respirators and filters are designed to prevent the spread of pathogenic aerosols, a stockpile shortage is anticipated during the next flu pandemic. Contact transfer and reaerosolization of collected microbes from used respirators are also a concern. An option to address these potential problems is UV irradiation, which inactivates microbes by dimerizing thymine/uracil in nucleic acids. The objective of this study was to determine the effects of transmission mode and environmental conditions on decontamination efficiency by UV. In this study, filters were contaminated by different transmission pathways (droplet and aerosol) using three spraying media (deionized water [DI], beef extract [BE], and artificial saliva [AS]) under different humidity levels (30% [low relative humidity {LRH}], 60% [MRH], and 90% [HRH]). UV irradiation at constant intensity was applied for two time intervals at each relative humidity condition. The highest inactivation efficiency (IE), around 5.8 logs, was seen for DI aerosols containing MS2 on filters at LRH after applying a UV intensity of 1.0 mW/cm2 for 30 min. The IE of droplets containing MS2 was lower than that of aerosols containing MS2. Absorption of UV by high water content and shielding of viruses near the center of the aggregate are considered responsible for this trend. Across the different media, IEs in AS and in BE were much lower than in DI for both aerosol and droplet transmission, indicating that solids present in AS and BE exhibited a protective effect. For particles sprayed in a protective medium, RH is not a significant parameter.
The aim of this study was to demonstrate a prototype tool for measuring infectivity of an aerosolized human pathogen – influenza A/PR/8/34 (H1N1) virus – using a small‐animal model in the Controlled Aerosol Test System (CATS).
: In this era of competent materials and fabrication for air filtration the factor dictating the protection factor (ratio of concentration outside to inside the respirator) is unfiltered inward leakage. Respirator testing using humans is constrained by the requirement for advance approval of the protocol by a human use committee, by the diversity and caprices of the subjects used in testing, by factors such as fatigue and illness, and by health hazards of aerosol challenges. Hanson Robotics has designed and built a robotic headform with dimensions matching those of the medium headform identified from a NIOSH wearers panel. The polyurethane skull form and polydimethylsiloxane artificial skin covering (Frubber) also accurately reproduce skin thicknesses measured for a panel of male Caucasians aged 19 -22 and provide a good simulation of the gross surface texture of human skin and its elastic response to touch. An initial static test of fit of seven models of N95 respirators to a static prototype prepared from similar materials in the same dimensions showed a typical scatter of measured fit factors (FFs) after donning, and an average FF of slightly more than 200 in a second series of donnings in which a leak check was used to exclude samples for which FF was 100, showing that the headform does closely resemble a human head in the NIOSH medium size window. Statistical validation that this similarity constitutes functional equivalence is underway.