The European Spallation Source (ESS), presently under construction in Lund, Sweden, is a multidisciplinary international laboratory that, once completed at full specifications, will operate the world's most powerful pulsed neutron source. Supported by a 3 M Euro Research and Innovation Action within the European Union Horizon 2020 program, a design study (HighNESS) is now underway to develop a second neutron source located below the spallation target. Compared to the first source, which is located above the spallation target and designed for high cold and thermal brightness, the new source is being optimized to deliver higher intensity and a shift to longer wavelengths in the spectral regions of cold neutrons (CNs) (2 to 20 & Aring;), very cold neutrons (VCNs) (10 to 120 & Aring;), and ultracold neutrons (UCNs) (> 500 & Aring;). The second source consists of a large liquid deuterium moderator to deliver CNs and serve secondary VCN and UCN sources, for which different options are under study. These new sources will boost several areas of condensed matter research and will provide unique opportunities in fundamental physics. The HighNESS project is now entering its last year, and we are working toward the Conceptual Design Report of the ESS upgrade. In this paper, results obtained in the first 2 years, ongoing developments, and future perspectives are described.
A key aim of the HighNESS project for the European Spallation Source is to enable cutting-edge particle physics experiments. This volume presents a conceptual design report for the NNBAR experiment. NNBAR would exploit a new cold lower moderator to make the first search in over thirty years for free neutrons converting to anti-neutrons. The observation of such a baryon-number-violating signature would be of fundamental significance and tackle open questions in modern physics, including the origin of the matter-antimatter asymmetry. This report shows the design of the beamline, supermirror focusing system, magnetic and radiation shielding, and anti-neutron detector necessary for the experiment. A range of simulation programs are employed to quantify the performance of the experiment and show how background can be suppressed. For a search with full background suppression, a sensitivity improvement of three orders of magnitude is expected, as compared with the previous search. Civil engineering studies for the NNBAR beamline are also shown, as is a costing model for the experiment.
Presently under construction in Lund, Sweden, the European Spallation Source (ESS) will be the world's brightest neutron source. As such, it has the potential for a particle physics program with a unique reach and which is complementary to that available at other facilities. This paper describes proposed particle physics activities for the ESS. These encompass the exploitation of both the neutrons and neutrinos produced at the ESS for high precision (sensitivity) measurements (searches).
The European Spallation Source, currently under construction in Lund, Sweden, is a multidisciplinary international laboratory. Once completed to full specifications, it will operate the world’s most powerful pulsed neutron source. Supported by a 3 million Euro Research and Innovation Action within the EU Horizon 2020 program, a design study (HighNESS) has been completed to develop a second neutron source located below the spallation target. Compared to the first source, designed for high cold and thermal brightness, the new source has been optimized to deliver higher intensity, and a shift to longer wavelengths in the spectral regions of cold (CN, 2–20 Å), very cold (VCN, 10–120 Å), and ultracold (UCN, >500 Å) neutrons. The second source comprises a large liquid deuterium moderator designed to produce CN and support secondary VCN and UCN sources. Various options have been explored in the proposed designs, aiming for world-leading performance in neutronics. These designs will enable the development of several new instrument concepts and facilitate the implementation of a high-sensitivity neutron-antineutron oscillation experiment (NNBAR). This document serves as the Conceptual Design Report for the HighNESS project, representing its final deliverable.
The European Spallation Source ESS is being constructed in Lund, Sweden, to be the world's brightest cold pulsed spallation neutron source. The facility uses a 2GeV proton beam hitting a target to produce neutrons. The neutrons are then thermalized in a moderator. Surrounding the moderator are several beam ports connected to neutron guides that transport the cold neutrons. Due to the long-pulse source nature of the ESS, neutron scattering instruments are significantly longer than at most existing facilities, with approximately half the instruments requiring neutron guides that are 150 meters long and only a few shorter than 50 meters. Therefore the shielding cost is dominated by the guide shielding. To fulfill the shielding requirement, a 'Common Shielding Project' has been initiated to deliver cost-effective and standardized solutions for several instruments. This includes both a consistent design of the shielding blocks, as well as a common approach to neutronics simulations.
Neutron scattering is an essential element in the materials science toolkit, providing unique structural and dynamic information.It relies on an ecosystem of facilities and smaller sources, which provide access to researchers covering a vast range of scientific problems.This talk will provide an overview of the current global neutron landscape, both today and in the near future.I aim to demonstrate the scientific impact, diversity and vitality of this ecosystem, highlighting the important role that neutron scattering plays in addressing a number of societally-impactful grand challenges.
The general performance of diffractometers at the first long pulse spallation source ESS, is compared with their counterparts at J-PARC, a short pulse spallation source. The difference in the inherent pulse structure of these neutron sources presents opportunities for new concepts for instrumentation, where performance does not scale simply with source power. The article describes advantages and disadvantages of those diffractometers, adapting to the very different source characteristics. We find that the two sources offer comparable performance in flux and resolution when operating in high-resolution mode. ESS offers significant advantages in tunability and flexibility, notably in the ability to relax resolution in order to increase flux for a given experiment. The slow repetition rate of ESS favors long instruments. On the other hand, J-PARC instruments perform very well in spite of the lower source power and allow better access to epithermal neutrons, of particular interest for PDF analysis of diffraction data.
The European Spallation Source being constructed in Lund, Sweden will provide the user community with a neutron source of unprecedented brightness. By 2025, a suite of 15 instruments will be served by a high-brightness moderator system placed above the spallation target. The ESS infrastructure, consisting of the proton linac, the target station, and the instrument halls, allows for implementation of a second source below the spallation target. We propose to develop a second neutron source with a high-intensity moderator able to (1) deliver a larger total cold neutron flux, (2) provide high intensities at longer wavelengths in the spectral regions of Cold (4-10 \AA ), Very Cold (10-40 \AA ), and Ultra Cold (several 100 \AA ) neutrons, as opposed to Thermal and Cold neutrons delivered by the top moderator. Offering both unprecedented brilliance, flux, and spectral range in a single facility, this upgrade will make ESS the most versatile neutron source in the world and will further strengthen the leadership of Europe in neutron science. The new source will boost several areas of condensed matter research such as imaging and spin-echo, and will provide outstanding opportunities in fundamental physics investigations of the laws of nature at a precision unattainable anywhere else. At the heart of the proposed system is a volumetric liquid deuterium moderator. Based on proven technology, its performance will be optimized in a detailed engineering study. This moderator will be complemented by secondary sources to provide intense beams of Very- and Ultra-Cold Neutrons.
The performance of typical spectrometers at ESS, which is the first long pulse spallation source, has been compared with that of counterparts in J-PARC in a general fashion. The difference of the source nature results in a clear difference in the expected performance, in addition to that which can simply be expected from the difference in the source power. The article tries to show the advantages and disadvantages of the very different source character between ESS and J-PARC, and to make some suggestions on instrumentation to extract the full potential from them.
It is with great sadness that we learned of the passing of experimental physicist and Jesuit priest, Otto Scharpf, who died in Munich on June 13 in his 90th year.Otto was born in 1929. He joined th...
A cost-effective chopper layout for the chopper cascade of MIRACLES, the time-of-flight backscattering spectrometer of the European Spallation Source is described. The main driving force is the capability to display a versatile and flexible selection of configuration modes, taking advantage of the long ESS pulse and tailoring the instrument resolution ad hoc, and covering a broad range of observation times from 10 ps to the ns. A key element for the design here presented is the feasibility to reach an energy resolution contribution from the incident neutron beam of similar to 1.2 mu eV, while keeping the same performance of MIRACLES conceptual design. The present optimized concept results in a well-balanced combination with the contribution from the secondary spectrometer time-of-flight energy resolution, yielding a total energy resolution of 2 mu eV at best, and 2.5 mu eV when the primary and secondary spectrometer contributions are matched.
We present the concept of a novel time-focusing technique for neutron spectrometers, which allows us to disentangle time-focusing from beam divergence. The core of this approach is a double rotating-crystal monochromator that can be used to extract a larger wavelength band from a white beam, thus providing a higher flux at the sample compared to standard time-of-flight instruments, yet preserving energy resolution and beam collimation. The performances of a spectrometer based on this approach are quantitatively discussed in terms of possible incident wavelengths, flux at the sample, and (Q, E)-resolution. Analytical estimates suggest flux gains of about one order of magnitude at comparable resolutions in comparison to conventional time-of-flight spectrometers. Moreover, the double monochromator configuration natively shifts the sample away from the source line-of-sight, thus significantly improving the signal-to-noise ratio. The latter, in combination with a system that does not increase the beam divergence, brings the further advantage of a cleaner access to the low-Q region, which is recognized to be of fundamental interest for magnetism and for disordered materials, from glasses to biological systems.
The vertical sample-plane reflectometer D17 at the Institut Laue–Langevin in Grenoble, France, has undergone several major upgrades since its commissioning, which are summarized in this article. The three major improvements are (i) a new focusing guide, increasing the usable flux on the sample by a factor of 2.5; (ii) a new beam polarizer and new spin flippers, allowing for the use of polarized neutrons in time-of-flight mode; and (iii) a new detector with a particularly uniform response under homogeneous exposure, improved stability and state-of-the-art detector electronics. The combination of these factors has paved the road to new possibilities in fast kinetic measurements, magnetism and off-specular scattering. Examples and scientific references for the new capabilities are presented.
The ESS has a characteristic design of the target and moderator system. The 2.5m-diameter target wheel needs a large horizontal vacant space around the moderator, and a thin moderator produces more high energy neutrons (HEN) in comparison with other facilities. Therefore, it is quite important to avoid HEN as much as possible before ejecting them into the beam line, although a curved guide or T0 chopper can get rid of them. In this report we show the present situation of these issues and discuss the measures to be taken.
The European Spallation Source will have 42 beam ports as a grid available for a variety of instruments, mostly neutron scattering experiments. Bi-spectral extraction for thermal and cold neutrons must be available to all the beam ports. The moderator design to deliver such neutron beams was driven by the low-dimensional moderator concept. The adopted design, consisting of one flat (3 cm high) moderator placed above the spallation target was considered valid for the initial instruments suite. ESS will however have a beam port system designed such that it will be possible to extract neutrons from moderators above and below the target. With all initial instruments pointing to the top moderator, this opens the possibility to have different types of moderators at the bottom, so that other neutron beams of different intensity, or spectral shape, with respect to the ones delivered by the top moderator, could be envisaged, adding additional scientific opportunities to the facility.
We present a wide-angle device for inelastic neutron scattering with XYZ-polarisation analysis (PASTIS2). PASTIS2 employs a banana-shaped Si-walled 3He-filter for the polarisation analysis and allows pillar-free neutron scattering for horizontal scattering angles 0–100◦. The guide field direction at the sample can be chosen vertical or with 45◦ incremental steps in the horizontal scattering plane. When PASTIS2 is implemented on a polarised neutron beam, the incident neutron spin can be flipped with an easy-to-optimise broad-band adiabatic resonant flipper (CROCODILE) independent of the guide field direction at the sample position. We have tested the performance of this new device on the polarised thermal triple-axis spectrometer IN20 at the Institut Laue-Langevin, equipped with Heusler monochromator and the FlatCone multi-analyser, and discuss its potential for future instruments.
We argue that it is not too early to begin the planning process for a next generation neutron source for Europe, even as the European Spallation Source is being constructed. We put forward three main arguments. Firstly, nowadays the period between the first scientific concept of a new facility being proposed and its actual realisation is approaching half a century. We show evidence for this. Secondly, there is a straightforward development of the short pulse/long pulse spallation concepts that will deliver gains in neutron brightness of more than a factor 30 over what the ESS will soon deliver and provide the optimum balance between resolution and intensity. We describe our concept, which is a spallation source where the proton pulse length is matched to the moderating time of slow neutrons. Thirdly, when we look at our colleagues in astronomy and high energy physics, we see that they have a totally different, more global and more ambitious approach to the coming generations of large facilities. We argue that it is time for the neutron community not simply to rest upon its laurels and take what is given but to be proactive..