Purpose To evaluate vessel assessment in virtual monoenergetic images (VMI 40keV ) and virtual-non-contrast images (VNC) derived from venous phase spectral detector computed tomography (SDCT) acquisitions in comparison to arterial phase and true non-contrast (TNC) images. Methods Triphasic abdominal SDCT was performed in 25 patients including TNC, arterial and venous phase. VMI 40keV and VNC were reconstructed from the venous phase and compared to conventional arterial-phase images (CI art ), TNC and conventional venous-phase images (CI ven ). Vessel contrast and virtual contrast removal were analyzed with region-of-interest-based measurements and in a qualitative assessment. Results Quantitative analysis revealed no significant attenuation differences between TNC and VNC in arterial vessels ( p -range 0.07–0.47) except for the renal artery ( p = 0.011). For venous vessels, significant differences between TNC and VNC were found for all veins ( p < 0.001) except the inferior vena cava ( p = 0.26), yet these differences remained within a 10 HU range in most patients. No significant attenuation differences were found between CI art /VMI 40keV in arterial vessels ( p -range 0.06–0.86). Contrast-to-noise ratio provided by VMI 40keV and CI art was equivalent for all arterial vessels assessed ( p -range 0.14–0.91). Qualitatively, VMI 40keV showed similar enhancement of abdominal and pelvic arteries as CI art and VNC were rated comparable to TNC. Conclusion Our study suggests that VNC and VMI 40keV derived from single venous-phase SDCT offer comparable assessment of major abdominal vessels as provided by routine triphasic examinations, if no dynamic contrast information is required.
OBJECTIVE:The purpose of the study was to investigate the potential added value of 18F-FDG-PET/MRI (functional information derived from PET) over standard diagnostic liver MRI (excellent soft tissue characterization) in diagnosing and staging suspected primary hepatobiliary malignancies including extrahepatic cholangiocarcinoma (ECC), intrahepatic cholangiocellular carcinoma (ICC) and gallbladder cancer (GBCA).METHODS:Twenty consecutive patients with suspected hepatobiliary malignancy were included in this retrospective study. All patients underwent combined whole-body (WB) 18F-FDG-PET/MRI including contrast-enhanced MRI of the liver, contrast-enhanced WB-MRI and WB 18F-FDG-PET. Two experienced readers staged hepatobiliary disease using TNM criteria: first based on MRI alone and then based on combined 18F-FDG-PET/MRI. Subsequently, the impact of FDG-PET/MRI on clinical management compared to MRI alone was recorded. Histopathologic proof served as the reference standard.RESULTS:Hepatobiliary neoplasms were present in 16/20 patients (ECC n = 3, ICC n = 8, GBCA n = 5), two patients revealed benign disease, two were excluded. TNM staging with 18F-FDG-PET/MRI was identical to MRI alone in 11/18 (61.1 %) patients and correctly changed the stage in 4/18 (22.2 %), resulting in a change in management for 2/4 patients (11.1 %). 18F-FDG-PET/MRI was false-positive in 3/18 cases (16.7 %). Both MRI and 18F-FDG-PET/MRI were falsely positive in 1 case without malignancy.CONCLUSIONS:A small incremental benefit of 18F-FDG-PET/MRI over standard MRI of the liver was observed. However, in some cases 18F-FDG-PET/MRI may lead to false-positive findings. Overall there is seemingly limited role of 18F-FDG-PET/MRI in patients with suspected hepatobiliary malignancy.
ObjectivesComprehensive training in ultrasound (US) imaging during radiology residency is crucial if radiologists are expected to maintain a substantial role in this widely used imaging modality. This study aimed to evaluate the current curriculum of US training among radiology residency programs across the country via a nationwide survey.MethodsA 28‐question survey was distributed among all academic radiology departments in the United States and their radiology residents. The survey consisted of 4 sections: general demographic information, training information, clinical competency, and adequacy of training (perspective). The Student t test and 1‐way analyses of variance were performed to assess statistical significance.ResultsOverall, 256 residents from 32 states completed the questionnaire. Only 114 (45%) residents reported having a dedicated rotation for performing US studies. Although 228 (89%) of trainees believed they received adequate experience for interpreting US studies, only 66 (26%) of them had the same belief about performing them. Only 116 (45%) of the residents were comfortable operating the US machines in their departments. Higher years of residency training, having a dedicated rotation for performing US studies, and having more than 10 hours per year of didactic lectures and/or more than 5 hours per year of case conferences dedicated to US had a positive impact on the residents' clinical competency and perspective (all P < .05).ConclusionsMost radiology residents do not feel confident in performing US examinations by themselves. However, higher clinical competency was reported in the residents who had dedicated rotations for performing US studies and received more hours of US lectures and case conferences throughout their residency.
BACKGROUND:In abdominal imaging, contrast-enhanced computed tomography (CT) examinations are most commonly applied; however, unenhanced examinations are still needed for several clinical questions but require additional scanning and radiation exposure.PURPOSE:To evaluate accuracy of virtual non-contrast (VNC) from arterial and venous phase spectral-detector CT (SDCT) scans compared to true-unenhanced (TNC) images for the evaluation of liver parenchyma and vessels.MATERIAL AND METHODS:A total of 25 patients undergoing triphasic SDCT examinations were included. VNC was reconstructed from arterial and venous phases and compared to TNC images. Quantitative image analysis was performed by region of interest (ROI)-based assessment of mean and SD of attenuation (HU) in each liver segment, spleen, portal vein, common hepatic artery, and abdominal aorta. Subjectively, iodine subtraction and diagnostic assessment were rated on 5-point Likert scales.RESULTS:Attenuation and image noise measured in the liver from VNC were not significantly different from TNC (TNC: 54.6 ± 10.8 HU, VNC arterial phase: 55.7 ± 10.8 HU; VNC venous phase: 58.3 ± 10.0 HU; P > 0.05). VNC also showed accurate results regarding attenuation and image noise for spleen, portal vein, and abdominal aorta. Only iodine subtraction in the common hepatic artery in the arterial phase was insufficient which was confirmed by the subjective reading. Apart from that, subjective reading showed accurate iodine subtraction and comparable diagnostic assessment.CONCLUSION:VNC from the arterial and venous phases were very similar to TNC yielding mostly negligible differences in attenuation, image noise, and diagnostic utility. Inadequate iodine subtraction occurred in hepatic arteries in the arterial phase.
PURPOSE Accurate photon attenuation assessment from MR data remains an unmet challenge in the thorax due to tissue heterogeneity and the difficulty of MR lung imaging. As thoracic tissues encompass the whole physiologic range of photon absorption, large errors can occur when using, for example, a uniform, water-equivalent or a soft-tissue-only approximation. The purpose of this study was to introduce a method for voxel-wise thoracic synthetic CT (sCT) generation from MR data attenuation correction (AC) for PET/MR or for MR-only radiation treatment planning (RTP). METHODS Acquisition: A radial stack-of-stars combining ultra-short-echo time (UTE) and modified Dixon (mDixon) sequence was optimized for thoracic imaging. The UTE-mDixon pulse sequence collects MR signals at three TE times denoted as UTE, Echo1, and Echo2. Three-point mDixon processing was used to reconstruct water and fat images. Bias field correction was applied in order to avoid artifacts caused by inhomogeneity of the MR magnetic field. ANALYSIS Water fraction and R2* maps were estimated using the UTE-mDixon data to produce a total of seven MR features, that is UTE, Echo1, Echo2, Dixon water, Dixon fat, Water fraction, and R2*. A feature selection process was performed to determine the optimal feature combination for the proposed automatic, 6-tissue classification for sCT generation. Fuzzy c-means was used for the automatic classification which was followed by voxel-wise attenuation coefficient assignment as a weighted sum of those of the component tissues. Performance evaluation: MR data collected using the proposed pulse sequence were compared to those using a traditional two-point Dixon approach. Image quality measures, including image resolution and uniformity, were evaluated using an MR ACR phantom. Data collected from 25 normal volunteers were used to evaluate the accuracy of the proposed method compared to the template-based approach. Notably, the template approach is applicable here, that is normal volunteers, but may not be robust enough for patients with pathologies. RESULTS The free breathing UTE-mDixon pulse sequence yielded images with quality comparable to those using the traditional breath holding mDixon sequence. Furthermore, by capturing the signal before T2* decay, the UTE-mDixon image provided lung and bone information which the mDixon image did not. The combination of Dixon water, Dixon fat, and the Water fraction was the most robust for tissue clustering and supported the classification of six tissues, that is, air, lung, fat, soft tissue, low-density bone, and dense bone, used to generate the sCT. The thoracic sCT had a mean absolute difference from the template-based (reference) CT of less than 50 HU and which was better agreement with the reference CT than the results produced using the traditional Dixon-based data. CONCLUSION MR thoracic acquisition and analyses have been established to automatically provide six distinguishable tissue types to generate sCT for MR-based AC of PET/MR and for MR-only RTP.
We propose a new method for generating synthetic CT images from modified Dixon (mDixon) MR data. The synthetic CT is used for attenuation correction (AC) when reconstructing PET data on abdomen and pelvis. While MR does not intrinsically contain any information about photon attenuation, AC is needed in PET/MR systems in order to be quantitatively accurate and to meet qualification standards required for use in many multi-center trials. Existing MR-based synthetic CT generation methods either use advanced MR sequences that have long acquisition time and limited clinical availability or use matching of the MR images from a newly scanned subject to images in a library of MR-CT pairs which has difficulty in accounting for the diversity of human anatomy especially in patients that have pathologies. To address these deficiencies, we present a five-phase interlinked method that uses mDixon MR acquisition and advanced machine learning methods for synthetic CT generation. Both transfer fuzzy clustering and active learning-based classification (TFC-ALC) are used. The significance of our efforts is fourfold: 1) TFC-ALC is capable of better synthetic CT generation than methods currently in use on the challenging abdomen using only common Dixon-based scanning. 2) TFC partitions MR voxels initially into the four groups regarding fat, bone, air, and soft tissue via transfer learning; ALC can learn insightful classifiers, using as few but informative labeled examples as possible to precisely distinguish bone, air, and soft tissue. Combining them, the TFC-ALC method successfully overcomes the inherent imperfection and potential uncertainty regarding the co-registration between CT and MR images. 3) Compared with existing methods, TFC-ALC features not only preferable synthetic CT generation but also improved parameter robustness, which facilitates its clinical practicability. Applying the proposed approach on mDixon-MR data from ten subjects, the average score of the mean absolute prediction deviation (MAPD) was 89.78±8.76 which is significantly better than the 133.17±9.67 obtained using the all-water (AW) method (p=4.11E-9) and the 104.97±10.03 obtained using the four-cluster-partitioning (FCP, i.e., external-air, internal-air, fat, and soft tissue) method (p=0.002). 4) Experiments in the PET SUV errors of these approaches show that TFC-ALC achieves the highest SUV accuracy and can generally reduce the SUV errors to 5% or less. These experimental results distinctively demonstrate the effectiveness of our proposed TFCALC method for the synthetic CT generation on abdomen and pelvis using only the commonly-available Dixon pulse sequence.
Objectives: To evaluate the added value of spectral results derived from Spectral Detector CT (SDCT) to the characterization of renal cystic lesions (RCL). Methods: This retrospective study was approved by the local Institutional review board. 70 consecutive patients who underwent abdominopelvic SDCT and had at least one RCL were included. 84 RCL were categorized as simple, complex or neoplastic based on attenuation values on single-phase post-contrast images. Attenuation values were measured in each lesion on standard conventional CT images (stCI) and virtual monoenergetic images of 40keV and 100keV. A spectral curve slope was calculated and intra lesional iodine concentration (IC) was measured using iodine-density maps. Reference standard was established using histopathologic correlation, prior and follow-up imaging. Analysis of variance (ANOVA) was used to compare between the groups. Results: Mean attenuation values for benign simple and complex RCL differed significantly (42 ± 16 vs 8 ± 3 HU; p < 0.001). IC was almost identical in benign simple and complex RCL (0.23 ± 0.04 mg ml−1 vs 0.24 ± 0.04 mg ml−1), while IC in neoplastic RCL was significantly higher (2.10 ± 0.08 mg ml−1 ; p < 0.001). The mean spectral curve slope did not differ significantly between simple and complex RCL (0.30 ± 0.03 vs 0.33 ± 0.05) but was significantly higher in neoplastic RCL (2.60 ± 0.10; p < 0.001). Conclusions: Spectral results of SDCT are highly promising in distinguishing benign complex RCL from enhancing neoplastic RCL based on single-phase post-contrast imaging only. Advances in knowledge: SDCT can assist in differentiating between benign complex and neoplastic renal cystic lesions.
OBJECTIVE To evaluate the performance of a rapid, low cost, noncontrast MRI examination as a secondary screening tool in detection of clinically significant prostate cancer. METHODS In this prospective single institution study, 129 patients with elevated prostate-specific antigen levels or abnormal digital rectal examination findings underwent MRI with an abbreviated biparamatric MRI protocol consisting of high-resolution axial T2- and diffusion-weighted images. Index lesions were classified according to modified Prostate Imaging-Reporting and Data System (mPI-RADS) version 2.0. All patients underwent standard transrectal ultrasound-guided biopsy after MRI with the urologist being blinded to MRI results. Subsequently, all patients with suspicious lesions (mPI-RADS 3, 4, or 5) underwent cognitively guided targeted biopsy after discussion of MRI results with the urologist. Sensitivity and negative predictive value for identification of clinically significant prostate cancer (Gleason score 3+4 and above) were determined. RESULTS Rapid biparametric MRI discovered 176 lesions identified in 129 patients. Rapid MRI detected clinically significant cancers with a sensitivity of 95.1% with a negative predictive value of 95.1% and positive predictive value of 53.2%, leading to a change in management in 10.8% of the patients. False negative rate of biparametric (bp) MRI was 4.7%. CONCLUSION We found that a bp-MRI examination can detect clinically significant lesions and changed patient management in 10.8% of the patients. A rapid MRI protocol can be used as a useful secondary screening tool in men presenting with suspicion of prostate cancer. (C) 2018 Elsevier Inc.
Castleman disease (CD) is a rare lymphoproliferative disorder of unknown etiology that may occur anywhere in the lymphatic system. Imaging plays an important role in detecting and staging this disease. Positron Emission Tomography/Magnetic Resonance Imaging (PET/MRI) combines the metabolic information derived from nuclear medical imaging with the high soft tissue resolution from MRI. We review the features of CD in standard diagnostic imaging, analyze the specific imaging findings of CD in FDG-PET/MRI and discuss a potential benefit of PET/MRI based on the case of a 15-year-old female patient with retroperitoneal CD.
We seek to characterize differences in the shape of the prostate and the central gland (combined central and transitional zones) between men with biopsy confirmed prostate cancer and men who were identified as not having prostate cancer either on account of a negative biopsy or had pelvic imaging done for a non-prostate malignancy. T2w MRI from 70 men were acquired at three institutions. The cancer positive group (PCa+) comprised 35 biopsy positive (Bx+) subjects from three institutions (Gleason scores: 6–9, Stage: T1–T3). The negative group (PCa−) combined 24 biopsy negative (Bx−) from two institutions and 11 subjects diagnosed with rectal cancer but with no clinical or MRI indications of prostate cancer (Cl−). The boundaries of the prostate and central gland were delineated on T2w MRI by two expert raters and were used to construct statistical shape atlases for the PCa+, Bx− and Cl− prostates. An atlas comparison was performed via per-voxel statistical tests to localize shape differences (significance assessed at p < 0.05). The atlas comparison revealed central gland hypertrophy in the Bx− subpopulation, resulting in significant volume and posterior side shape differences relative to PCa+ group. Significant differences in the corresponding prostate shapes were noted at the apex when comparing the Cl− and PCa+ prostates.