Fabrication of multi-chamber microcapsules is of great interest in biotechnology, 3D cell culture, microfluidics, and other applications. The centrifuge-based droplet shooting device (CDSD) is a valuable method for multi-chamber microcapsule production, but is limited by loading difficulty and low volumes. We present a new CDSD system that is easy to load for multi-chamber high- or low-volume applications. We describe the structure, characteristics, and principle demonstration of the device. We experimentally determine trends of droplet shape differences and the resulting conditions of glob formation (due to collision with the centrifuge wall) with > 97
Nanoscale and microscale cell-derived extracellular vesicle types and subtypes are of significant interest to researchers in biology and medicine. Extracellular vesicles (EVs) have diagnostic and therapeutic potential in terms of biomarker and nanomedicine applications. To enable such applications, EVs must be isolated from biological fluids or separated from other EV types. Developing methods to fractionate EVs is of great importance to EV researchers. Our goal was to begin to develop a device that would separate medium EVs (mEVs, traditionally termed microvesicles or shedding vesicles) and small EVs (sEVs, traditionally termed exosomes) by elasto-inertial effect. We sought to develop a miniaturized technology that works similar to and provides the benefits of differential ultracentrifugation but is more suitable for EV-based microfluidic applications. The aim of this study was to determine whether we could use elasto-inertial focusing to re-isolate and recover U87 mEVs and sEVs from a mixture of mEVs and sEVs isolated initially by one round of differential ultracentrifugation. The studied spiral channel device can continuously process 5 ml of sample fluid per hour. Using the channel, sEVs and mEVs were recovered and re-isolated from a mixture of U87 glioma cell-derived mEVs and sEVs pre-isolated by one round of differential ultracentrifugation. Following two passes through the spiral channel, approximately 55% of sEVs were recovered with 6% contamination by mEVs (the recovered sEVs contained 6% of the total mEVs). In contrast, recovery of U87 mEVs and sEVs re-isolated using a typical second centrifugation wash step was only 8% and 53%, respectively. The spiral channel also performed similar to differential ultracentrifugation in reisolating sEVs while significantly improving mEV reisolation from a mixture of U87 sEVs and mEVs. Ultimately this technology can also be coupled to other microfluidic EV isolation methods in series and/or parallel to improve isolation and minimize loss of EV subtypes.
In this work, a new high-volume, continuous particle separation device that separates based upon size and charge is described. Two continuous flow-electrical-split-flow lateral transport thin (Fl-El-SPLITT) device architectures (a platinum electrode on a porous membrane and a porous graphite electrode under a membrane) were developed and shown to improve particle separations over a purely electrical-SPLITT device. The graphite FL-El-SPLITT device architecture achieved the best separation of approximately 60% of small (28 nm) vs large (1000 nm) polystyrene particles. Fl-El-SPLITT (platinum) achieved a 75% separation on a single pass using these same particles. Fl-El-SPLITT (platinum) achieved a moderate 26% continuous separation of U87 glioma cell-derived small extracellular vesicles (EVs) from medium EVs. Control parameter testing showed that El-SPLITT continuously directed particle motility within a channel to exit a selected port based upon the applied voltage using either direct current or alternating current. The transition from one port to the other was dependent upon the voltage applied. Both large and small polystyrene particles transitioned together rather than separating at each of the applied voltages. These data present the first ever validation of El-SPLITT in continuous versus batch format. The Fl-El-SPLITT device architecture, monitoring, and electrical and fluid interfacing systems are described in detail for the first time. Capabilities afforded to the system by the flow addition include enhanced particle separation as well as the ability to filter out small particles or desalinate fluids. High-throughput continuous separations based upon electrophoretic mobility will be streamlined by this new technique that combines electrical and flow fields into a single device.
Herein, we describe the simulation of a novel flow-electrical-split flow thin (Fl-El-SPLITT) separation device and validate it using existing theory and experimentation for the first time using polystyrene particles of 28 and 1000 nm diameters. The fraction of particles exiting selected ports with DC El-SPLITT is predicted with existing theory, but the theory does not include AC fields, nor does it incorporate the use of crossflows. Using DC fields the El-SPLITT simulation and theory calculated transition points result in the same values. These calculated values accurately predict the experimentally obtained transition point using a 50:50 outlet splitting plane (OSP). Relative to actual experimentally obtained transition points, the calculated values lag behind for a 90:10 OSP, and lead ahead for a 10:90 OSP. The simulation explains trends seen in AC testing, and reasonably predicts the fraction of particles exiting each port. As DC current increases, the amount of AC current required to scatter the particles away from the DC-intended port decreases. The simulation also models a crossflow in a SPLITT system with a DC current applied in a direction opposite the crossflow with some success. Long term steady-state testing without crossflows shows a DC voltage dependent loss of particles. At 8 V DC, total recovery of 28 and 1000 nm particles was 70% and 26%, respectively. This work effectively models a new Fl-El-SPLITT system via Matlab simulation by demonstrating key experimental results such as the influence of DC, AC, and crossflows on the SPLITT separation of polystyrene particles.
Although many properties for small extracellular vesicles (sEVs, formerly termed "exosomes") isolated at ~100,000 x g are known, a wide range of values are reported for their electrophoretic mobility (EM) measurements. This paper reports for the first time the effect of dilution on the EM of U87 glioblastoma cell-derived and plasma-derived sEVs and medium size EVs (mEVs, commonly termed "oncosomes") pre-isolated by differential centrifugation. Furthermore, the effect of resalting on the EM of sEVs and mEVs was evaluated. The EM of U87 sEVs and U87 mEVs showed an increase as the salt concentration decreased to 0.005% of the initial salt concentration. However, for the plasma sEVs and plasma mEVs, the electrophoretic mobility increased as the salt concentration decreased to 0.01% of the initial salt concentration and then increased to its initial value when the salt concentration decreased to 0.005% of the initial salt concentration. For both U87 and plasma sEVs and mEVs, the EM remained almost constant when the concentration of the particles changed and the salt concentration was kept the same as its initial value. This indicates that the EM of EVs is only a function of the salt concentration of the buffer and is independent of the concentration of the particles. The sEVs and mEVs were separated with cyclical ElFFF for the first time. The results indicate that ElFFF was able to fractionate the EVs and a crescent-shaped trend was found for the retention time when the applied AC voltage was altered (increased).
Virus-like particles (VLPs) are widely used in medicine, but can be difficult to characterize and isolate from aggregates. In this research, primarily cyclical electrical field-flow fractionation (CyElFFF) coupled with multi-angle light scattering (MALS), and dynamic light scattering (DLS) detectors, was used for the first time to perform size and electrical characterization of three different types of Q beta bacteriophage virus-like particles (VLPs): a blank Q beta bacteriophage which is denoted as VLP and two conjugated ones with different peptides. The CyElFFF results were verified with transmission electron microscopy (TEM). Asymmetrical flow field-flow fractionation (AF4) coupled with MALS was also applied using conditions similar to those used in the CyElFFF experiments, and the results of the two techniques were compared to each other. Using these techniques, the size and electrophoretic characteristics of the fractionated VLPs in CyElFFF were obtained. The results indicate that CyElFFF can be used to obtain a clear distribution of electrophoretic mobilities for each type of VLP. Accordingly, CyElFFF was able to differentially retain and isolate VLPs with high surface electric charge/electrophoretic mobility from the ones with low electric charge/electrophoretic mobility. Regarding the size characterization, the size distribution of the eluted VLPs was obtained using both techniques. CyElFFF was able to identify subpopulations that did not appear in the AF4 results by generating a shoulder peak, whereas AF4 produced a single peak. Different size characteristics of the VLPs appearing in the shoulder peak and the main peak indicate that CyElFFF was able to isolate aggregated VLPs from the monomers partially. Graphical abstract.
Electrical field flow fractionation (EFFF) is a particle separation method that employs an electrical field to cause particles in the carrier flow transferring in the vertical direction. The electrical characteristics of EFFF are one of the important aspects to explore electrical field how to work on the particle separation in EFFF channel. The equivalent electrical circuit model of EFFF channel was built. The experiments of chronoamperometry and electrochemical impedance spectroscopy (EIS) were conducted on the EFFF channel. The electrical circuit was utilised to fit the data of EIS experiments on EFFF channel. The fitting data were compared with the experimental data of EIS. The result indicates that the experimental data is highly quantified with the fitting data. It manifested that the equivalent electrical circuit reflected the electrical characteristics of the EFFF channel.
Sperm preparation is critical to achieving a successful intrauterine insemination and requires the processing of a semen sample to remove white blood cells, wash away seminal plasma, and reduce sample volume. We present an automated instrument capable of performing a sperm preparation starting with a diluted semen sample. We compare our device against a density gradient centrifugation by processing 0.5 mL portions of patient samples through each treatment. In 5 min of operating time, the instrument recovers an average of 86% of all sperm and 82% of progressively motile sperm from the original sample while removing white blood cells, replacing the seminal plasma, and reducing the volume of the sample to the clinically required level. In 25 min of operating time, density gradient centrifugation recovers an average of 33% of all sperm and 41% of progressively motile sperm. The automated instrument could improve access to IUI as a treatment option by allowing satellite doctor’s offices to offer intrauterine insemination as an option for patients without the clinical support required by existing methods.
The influence of buffer substitution and dilution effects on exosome size and electrophoretic mobility were shown for the first time. Cyclical electrical field flow fractionation (Cy-El-FFF) in various substituted fluids was applied to exosomes and other particles. Tested carrier fluids of deionized (DI) water, 1× phosphate buffered saline (PBS), 0.308 M trehalose, and 2% isopropyl alcohol (IPA) influenced Cy-El-FFF-mediated isolation of A375 melanoma exosomes. All fractograms revealed a crescent-shaped trend in retention times with increasing voltage with the maximum retention time at ∼1.3 V AC. A375 melanoma exosome recovery was approximately 70-80% after each buffer substitution, and recovery was independent of whether the sample was substituted into 1× PBS or DI water. Exosome dilution in deionized water produced a U-shaped dependence on electrophoretic mobility. The effect of dilution using 1× PBS buffer revealed a very gradual change in electrophoretic mobility of exosomes from ∼-1.6 to -0.1 μm cm/s V, as exosome concentration was decreased. This differed from the use of DI water, where a large change from ∼-5.5 to -0.1 μm cm/s V over the same dilution range was observed. Fractograms of separated A375 melanoma exosomes in two substituted low-ionic-strength buffers were compared with synthetic particle fractograms. Overall, the ability of Cy-El-FFF to separate exosomes based on their size and charge is a highly promising, label-free approach to initially catalogue and purify exosome subtypes for biobanking as well as to enable further exosome subtype interrogations.
Exosomes participate in cancer metastasis, but studying them presents unique challenges as a result of their small size and purification difficulties. Asymmetrical field flow fractionation with in-line ultraviolet absorbance, dynamic light scattering, and multi-angle light scattering was applied to the size separation and characterization of non-labeled B16-F10 exosomes from an aggressive mouse melanoma cell culture line. Fractions were collected and further analyzed using batch mode dynamic light scattering, transmission electron microscopy and compared with known size standards. Fractogram peak positions and computed radii show good agreement between samples and across fractions. Ultraviolet absorbance fractograms in combination with transmission electron micrographs were able to resolve subtle heterogeneity of vesicle retention times between separate batches of B16-F10 exosomes collected several weeks apart. Further, asymmetrical field flow fractionation also effectively separated B16-F10 exosomes into vesicle subpopulations by size. Overall, the flow field flow fractionation instrument combined with multiple detectors was able to rapidly characterize and separate exosomes to a degree not previously demonstrated. These approaches have the potential to facilitate a greater understanding of exosome function by subtype, as well as ultimately allow for "label-free" isolation of large scale clinical exosomes for the purpose of developing future exosome-based diagnostics and therapeutics.