This study was investigated twenty two hazardous chemicals compounds for effluents of nine sewage treatment plants (STPs) and one waste water treatment plant (WWTP) in the Nakdong Ri-ver Basin. They are eleven phthalates(DMP, DEP, DIBP, DBP, BEEP, DNPP, DHP, DCP, DEHP, DNOP, Dinonyl phthalate, seven aliphatic hydrocarbons(n-Tridecane, n-Tetradecane, n-Pentadecan-e, n-Hexadecane, n-Heptadecane, n-Octadecane, n-Nonadecane, Isoquinoline, 2-Chloropyridine, 2-N-itrophenol, and Benzophenone. The twenty two compounds were analyzed by gas chromatograp-hy mass spectrometry (GC/MS) with liquid-liquid extraction (LLE). Twenteen of twenty two subs-tances were detected. They were DMP, DEP, DIBP, DBP, DEHP, n-Tetradecane, n-Pentadecane, n-Heptadecane, n-Octadecane, n-Nonadecane, Isoquinoline and Benzophenone. Among these, DEHP, DEP and Benzophenone were most frequently observed. They were obtained as $ND{\sim}36.881{\mu}g/L$, $ND{\sim}0.950{\mu}g/L$, $ND{\sim}2.019{\mu}g/L$, respectively. When the substances were calculated the average concentration at 10 points, the maximum average detection concentration was investigated at the Dalseocheon STP.
The survey of nitrosamine occurrence at Nakdong river is conducted in this study.According to the study results, six nitrosamine compounds (NDEA as N-nitrosodiethylamine, NDPA as N-Nitrosodi-n-propylamine, NDMA as N-nitrosodimethylamine, NMEA as N-nitrosomethylethylamine, NDBA as N-nitrosodi-n-butylamine, and NDPHA as N-Nitrosodiphenylamine) were detected at the Nakdong river.Among these, NDEA and NDPA are the most important compounds in terms of the nitrosamine contamination of Nakdong river.The detected concentration of NDEA exceeded the CDHCS (California Department of Health Care Services) response level of 100 ng/L at several sites.The detected concentration of NDPA approached the response level (500 ng/L) at few sites.When all nitrosamine concentrations were summed up, the maximum concentration of 735.7 ng/L was detected at the Nakdong river.
A highly sensitive analytical method based on stir bar sorptive extraction (SBSE) technique and gas chromatography/ tandem mass spectrometry (GC-MS/MS) has been developed, allowing the simultaneous multi-analyte determination of 11 synthetic fragrances (SFs) in water samples. The stir bar coated with polydimethylsiloxane (PDMS) was added to 40 mL of water sample at pH 3 and stirred at 1,100 rpm for 120 min. Other SBSE parameters (salt effect and presence of organic solvent) were optimised. The method shows good linearity (coefficients > 0.990) and reproducibility (RSD < 10.9%). The extraction efficiencies were above 83% for all the compounds. The limits of detections (LOD) and limits of quantification (LOQ) were 2.1~4.1 ng/L and 6.6~12.9 ng/L, respectively. The developed method offers the ability to detect 11 SFs at ultra-low concentration levels with only 40 mL of sample volume. Matrix effects in tap water, river water, wastewater treatment plant (WWTP) final effluent water and seawater were investigated and it was shown that the method is suitable for the analysis of trace level of 11 SFs. The method developed in the present study has the advantage of being rapid, simple, high-sensitive and both user and environmentally friendly.
This is made of domestic and foreign coal activated carbon of five species, physicochemical adsorption efficient about sterilize products and micro harmful substances and is a result of the economic evaluation.The most well-developed micropores bed volume 123,409 of AC-1 activate carbon appeared to be the best next AC-2, AC-3, AC-4, AC-5 followed by activated carbon was investigated.PFOA and PFOS in the BV 96,000 when evaluating foreign types of adsorption activated carbon adsorption capacity was greater when more than PFOA, PFOS showed that the adsorption well.The economic evaluation of activated carbon usage in chloroform (CUR) was most excellent as a AC-1 4.3 g/day, the next AC-2, AC-3, AC-4, AC-5 there are two types of foreign economic order appears to have appeared, but the current domestic market when applying the price AC-1, AC-3, AC-2, AC-4, AC-5 order was investigated.
Perfluorooctanoic acid (PFOA) and perfluorooctyl sulfonate (PFOS) is a new persistent organic pollutants of substantial environmental concern. This study investigated the potential of magnetic ion exchange resin (MIEX$^{(R)}$) as the adsorbent for the removal of PFOA and PFOS from Nakdong River water. In our batch experiments, we studied the effect of some parameters (pH, temperature, sulfate concentration) on the removal of PFOA and PFOS. The results of sorption kinetics on MIEX$^{(R)}$ show that it takes 90 min to reach equilibrium but the economical contact time and dosage were 30 min and 10 mL/L. An increase in pH (pH 6~10) leads to a decrease in PFOA (2.0%) and PFOS (3.6%) sorption on MIEX$^{(R)}$. The sorption of both PFOA and PFOS decreases with an increase in ionic strength for sulfate ion (${SO_4}^{2-}$), due to the competition phenomenon. An increase in water temperature ($8^{\circ}C{\sim}28^{\circ}C$) in water leads to a increase in PFOA (2.8%) and PFOS (4.3%) sorption on MIEX$^{(R)}$. Based on the sorption behaviors and characteristics of the adsorbents and adsorbates, ion exchange and hydrophobic interaction were deduced to be involved in the sorption, and hemi-micelles possibly formed in the intraparticle pores.
The aims of this study were to investigate and confirm the occurrence and distribution patterns of perfluorinated compounds (PFCs) in Nakdong River basin (mainstream and its tributaries). 7 (PFOS, PFHpA, PFOA, PFNA, PFDA, PFUnDA and PFDoDA) out of 11 PFCs were detected in 29 sampling sites and PFOA and PFHpA were predominant compounds in upstream, but PFUnDA, PFDoDA and PFOS were predominant compounds in middle stream of Nakdong River basin. The total concentration levels of PFCs on February 2009 and on August 2009 in surface water samples ranged from 4.3. to 1168.2 ng/L and 16.4 to 627.8 ng/L, respectively. The highest concentration level of PFCs in the mainstream and tributaries in Nakdong River were Goryeong and Jincheon-cheon, respectively. The sewage treatment plants (STPs) along the river affect the PFCs levels in river and the PFCs levels decreased with downstream because of dilution effects.
This study, changes in raw water quality is to indicate on the efficiency of ozone treatment of each pollutant as compared to derive the appropriate operating measures. The appropriate selection for injection rate of pre-ozone and did not inject pre-ozone assess changes in the water. When good water quality, you not injected of pre-ozone to evaluate the economic efficiency of electricity and put the most cost-effective ozone concentration were evaluated. Evaluation remove organic matter and chlorophyll-a concentration level in experiments with each factor of the water DOC> 2.5 / L, THMFP> 70 / L, Chl-a> 30 / or less constant process, if you do not need to put pre-ozone showed little impact. It also does not put you in pre-ozone appropriate produce enough power rate savings was calculated as approximately 90 million won. Ability to remove organic materials and the ability to produce disinfection byproducts, and cost-effective decisions by considering the concentration of injection if pre-ozone 1 mg/L was investigated by the appropriate concentration of ozone injection.