[68 Ga]Ga-PSMA-11 is a promising radiopharmaceutical for detecting tumour lesions in prostate cancer, but knowledge of the pharmacokinetics is limited. Dynamic PET-CT was performed to investigate the tumour detection and differences in temporal distribution, as well as in kinetic modelling of [68 Ga]Ga-PSMA-11 by tissue type. Dynamic PET-CT over the lower abdomen and static whole-body PET-CT 80–90 min p.i. from 142 patients with biochemical recurrence were retrospectively analysed. Detection rates were compared to PSA levels. Average time-activity curves were calculated from tumour lesions and normal tissue. A three-compartment model and non-compartment model were used to calculate tumour kinetics. Overall detection rate was 70.42%, and in patients with PSA > 0.4 ng/mL 76.67%. All tumour lesions presented the steepest standardised uptake value (SUV) incline in the first 7–8 min before decreasing to different degrees. Normal tissue presented with a low uptake, except for the bladder, which accumulated activity the steepest 15–16 min. p.i.. While all tumour lesions continuously increased, bone metastases showed the steepest decline, resulting in a significantly lower SUV than lymph node metastases (60 and 80–90 min). Transport rate from the blood and tracer binding and internalisation rate were lower in bone metastases. Heterogeneity (fractal dimension) and vascular density were significantly lower in bone metastases. Even at low PSA between 0.51 and 0.99 ng/mL, detection rate was 57%. Dynamic imaging showed a time window in the first 10 min where tumour uptake is high, but no bladder activity is measured, aiding accuracy in distinction of local recurrence. Kinetic modelling provided additional information for tumour characterisation by tissue type.
Aim of the present analysis is to investigate the biodistribution and pharmacokinetics of the recently clinically introduced radioligand 18F-PSMA-1007 in patients with biochemical recurrence or progression of prostate cancer (PC) by means of multiparametric (dynamic and whole-body) PET/CT. Twenty-five (25) patients with PC biochemical relapse or progression (median age = 66.0 years) were enrolled in the analysis. The median PSA value was 1.2 ng/mL (range = 0.1–237.3 ng/mL) and the median Gleason score was 7 (range = 6–10). All patients underwent dynamic PET/CT (dPET/CT) scanning (60 min) of the pelvis and lower abdomen as well as whole-body PET/CT with 18F-PSMA-1007. PET/CT assessment was based on qualitative evaluation, SUV calculation, and quantitative analysis based on a two-tissue compartment model and fractal analysis. 15/25 patients were PET-positive. Plasma PSA values in the 18F-PSMA-1007 positive group were higher (median = 3.6 ng/mL; range = 0.2–237.3 ng/mL) than in the 18F-PSMA-1007 negative group (median value = 0.7 ng/mL; range = 0.1–3.0 ng/mL). Semi-quantitative analysis in the PC lesions demonstrated a mean SUVaverage = 25.1 (median = 15.4; range = 3.5–119.2) and a mean SUVmax = 41.5 (median = 25.7; range = 3.8–213.2). Time–activity curves derived from dPET/CT revealed an increasing tracer accumulation during the 60 min of dynamic PET acquisition into the PC lesions, higher than in the urinary bladder and the colon. Significant correlations were observed between 18F-PSMA-1007 uptake (SUV), influx, and fractal dimension (FD). 18F-PSMA-1007 PET/CT could detect PC lesions in 60% of the patients of a mixed population, including also patients with very low PSA values. Higher PSA values were associated with a higher detection rate. Dynamic PET analysis revealed an increasing tracer uptake during the dynamic PET acquisition as well as high binding and internalization of the radiofluorinated PSMA ligand in the PC lesions.
68Ga-PSMA-11 PET/CT performed 60 min post tracer injection (p.i.) can underestimate prostate cancer (PC) local recurrence, due to high 68Ga-PSMA-11 urinary bladder accumulation. Aim of this analysis is to evaluate the complementary role of early dynamic and parametric PET imaging in patients with PC local recurrence. Sixteen patients with PC biochemical relapse attributed to local recurrence underwent dynamic 68Ga-PSMA-11 PET/CT scanning of the pelvis and whole-body PET/CT. Data analysis was based on visual analysis of the PET/CT scans, SUV calculations, quantitative analysis based on two-tissue compartment and Patlak models as well as parametric imaging based on Patlak analysis. 12/16 patients were PSMA-positive in the static 68Ga-PSMA-11 PET/CT scans (60 min p.i.). All 12 lesions corresponding to PC local recurrence were detected in the early dynamic images at a median time of 4.5 min p.i. (range = 1.5-11.5 min). Moreover, early dynamic PET imaging could detect local recurrence in 1/4 static PET/CT-negative patients. Tracer accumulation in the urinary bladder began at a median time of 10 min (range = 6.0-17.5 min). All PC local recurrences visible on late static PET/CT and the local recurrence, which was positive only in early dynamic but not in late PET images, could be delineated on Patlak images. The present findings indicate that early dynamic 68Ga-PSMA-11 PET/CT scan of the pelvis up to 12 min p.i. as well as Patlak analysis, performed in addition to the conventional PET/CT acquired at 60 min p.i., seem a practical approach to increase the detection rate of PC local recurrence.
TENPET (Trans European Network for Positron Emission Tomography) aims to evaluate the provision of integrated teleconsultation and intelligent computer supported cooperative work services for clinical positron emission tomography (PET) in Europe at its current stage, as it is a multi-centre project financially supported by the European Commission (Information Society, eTEN Program). It addresses technological challenges by linking PET centres and developing supporting services that permit remote consultation between professionals in the field. The technological platform (CE-marked) runs on Win2000/NT/XP systems and incorporates advanced techniques for image visualization, analysis and fusion, as well as for interactive communication and message handling for off-line communications. Four PET Centres from Spain, France and Germany participate to the pilot system trials. The performance evaluation of the system is carried out via log files and user-filled questionnaires on the frequency of the teleconsultations, their duration and efficacy, quality of the images received, user satisfaction, as well as on privacy, ethical and security issues. TENPET promotes the co-operation and improved communication between PET practitioners that are miles away from their peers or on mobile units, offering options for second opinion and training and permitting physicians to remotely consult patient data if they are away from their centre. It is expected that TENPET will have a significant impact in the development of new skills by PET professionals and will support the establishment of peripheral PET units. To our knowledge, TENPET is the first telemedicine service specifically designed for oncological PET. This report presents the technical innovations incorporated in the TENPET platform and the initial pilot studies at real and diverse clinical environments in the field of oncology.