Variable extra thoracic obstruction has been found in spirometric studies in subjects with unilateral vocal fold paralysis. The aim of the study was to further evaluate airflow dynamics in these subjects with body plethysmography and tracheal sound analysis. Ten patients with unilateral vocal fold paralysis without a history of chronic pulmonary diseases and 10 healthy control subjects were studied. Flow-volume spirometry, body plethysmography and tracheal sound analysis were performed within 1 day. The study shows that peak inspiratory flow (PIF) and specific airway conductance (SG(aw)) expressed as percentage of Finnish reference values were significantly lower and airway resistance (R(aw)) was higher among the patients than among the controls (P=0.004, P=0.026 and P=0.004, respectively). The patients had higher sound amplitude of both inspiratory and expiratory tracheal sounds than the controls [root mean square (RMS) values of the power spectra were 31.5 and 25 dB, P=0.006 in inspiration and 31.5 and 26 dB, P=0.013 in expiration, respectively]. Quartile frequencies (F25 and F50) and RMS of expiratory tracheal sounds had significant negative correlation with PIF (P=0.02, P<0.001, P=0.02, respectively) and forced inspiratory volume in 1 s (FIV(1)) (P=0.01, P<0.001, P=0.01, respectively). There was also an association between F50 and peak expiratory flow (PEF) (P=0.02). According to the present study, both quiet breathing and forced inspiration are disturbed in subjects with unilateral vocal fold paralysis. A close relationship between tracheal sounds and respiratory function tests exists.
The aim of this study was to investigate the changes in tracheal sounds and airflow dynamics in patients who underwent surgical medialization of a unilaterally paralysed vocal fold. Ten adults with unilateral vocal fold paralysis but no history of pulmonary diseases were included. Vocal fold medialization was performed by an injection of autologous fascia into the paralysed vocal fold. Recording of tracheal sounds, flow-volume spirometry and body plethysmography were carried out before and 4-14 months after the operation. The mean number of inspiratory wheezes per respiratory cycle increased from 0.02 (range 0-0.10) to 0.42 (range 0-0.86) and the mean number of expiratory wheezes per respiratory cycle from 0.03 (range 0-0.20) to 0.36 (range 0-0.89). The increment was statistically significant (P=0.03 and P=0.04, respectively). The mean expiratory sound amplitude, in terms of root mean square (RMS), increased from 31.5 dB (range 24.0-38.0) to 34.9 dB (range 25-42) (P=0.03) and the average peak inspiratory flow (PIF) decreased from 4.63 l s-1 (range 2.84-7.51) to 4.03 l s-1 (range 2.27-6.68) (P=0.01). The results indicate that when the paralysed vocal fold is brought into midline by a surgical procedure, the prevalence of inspiratory and expiratory wheezes increases and sound intensity rises. According to this preliminary data tracheal sound analysis gives additional information for the assessment of the subtle changes in the larynx.
A versatile PC-based lung sound analyzer has been developed for short-term recording and analysis of respiratory sounds in research and clinical applications. The system consists of two sound sensors, a flow sensor, a filtering signal amplifier and a PC with a data acquisition card and software for measurement and analysis of the sounds. The analyses include phonopneumography, time expanded waveform analysis, spectral analysis with time averaged Fast Fourier Transform, frequency analysis in time domain (sonogram), and automatic detection and waveform analysis of crackles. Short-term repeatability of spectral parameters of tracheal and lung sounds was studied in 10 healthy subjects. The coefficients of variation (CoV) of the averaged quartile frequencies (F25, F50 and F75) of lung sounds during flow-controlled tidal breathing were 3.7, 4.0 and 8.9% in expiration and 2.7, 3.5 and 4.5% in inspiration, respectively. CoVs of the averaged F25, F50 and F75 of expiratory tracheal sounds were 6.9, 3.0 and 2.4%, and those of inspiratory tracheal sounds 6.3, 2.6 and 3.3%, respectively. Examples of lung sound analysis of samples containing adventitious sounds such as crackles and wheezes are presented. The results indicate that the median frequency has the best repeatability of quartile frequencies of breath sounds and they suggest that the variations of those parameters are low enough for diagnostic purposes. The results also suggest that the analyzer can be a useful new tool for pulmonary research in the fields of physiological and clinical short-term studies of respiratory sounds.
Alcohol tolerance, measured as performance on the tilting plane after ethanol injection (2.5 g/kg body weight i.p.), was examined in the AA strain of rats which voluntarily drink large amounts of alcohol, in the ANA strain which drink very little alcohol, and in ordinary albino rats which consume intermediary amounts of alcohol. The AAs showed the highest innate ethanol tolerance; the ANAs had the lowest innate tolerance. After chronic alcohol administration, both AA and ANA strains increased their tolerance, but the AAs remained superior to the ANAs. The chronic ethanol treatment did not significantly change the (Na+K+) ATPase activity of the crude microsomal fraction of the brains of the strains.