OBJECTIVE:Maternal anaemia in early pregnancy is associated with poor pregnancy outcomes. Furthermore, preconceptional health can influence the health during pregnancy. The aim of this study was to investigate which preconceptional factors were associated with haemoglobin (Hb) concentration in early pregnancy. METHODS:In Tanzania, 226 women were followed at preconception and during early pregnancy. Red blood cell (RBC) morphology, serum micronutrient concentration, demographic characteristics and health status were assessed in preconception and in early pregnancy. The association between preconceptional factors and Hb concentration in early pregnancy was investigated using simple and multiple linear regression analyses stratified by preconceptional anaemia status. RESULTS:Mean Hb was 123 and 119 g/l before conception and during early pregnancy (median gestational age 53 days) respectively. Preconceptional mid-upper arm circumference (MUAC) (adjusted coefficient (AC) 0.35 95% CI 0.9-0.61) and preconceptional Hb concentration (AC 0.45 95% CI 0.36-0.54) were positively associated with early pregnancy Hb concentration, whereas preconceptional microcytic hypochromic RBC morphology (AC -6.00 95% CI -9.56 to -2.44) was negatively associated with early pregnancy Hb concentration. In addition, treatment of preconceptional malaria was positively associated with early pregnancy Hb concentration (AC 6.45 95% CI 0.74-12.2) among women with preconceptional anaemia. In contrast, among preconceptional non-anaemic women, only preconceptional Hb concentration and medium socio-economic status was positively associated with early pregnancy Hb concentration. CONCLUSIONS:Mid-upper arm circumference (MUAC) and Hb measurements in preconception can help to detect women at increased risk of low Hb concentration in early pregnancy.
BACKGROUND:Anemia is a major public health problem that adversely affects pregnancy outcomes. The prevalence of anemia among pregnant women before conception is not well known in Tanzania. The aim of this study was to determine the prevalence, types, and risk factors of preconception anemia in women of reproductive age from a rural Tanzanian setting.METHODS:Trained field workers visited households to identify all female residents aged 18-40 years and invited them to the nearby health facility for screening and enrolment into this study. Baseline samples were collected to measure hemoglobin levels, serum ferritin, vitamin B12, folate, C-reactive protein, alanine amino-transferase, the presence of malaria, HIV, and soil transmitted helminth infections. Anthropometric and socio-economic data were recorded alongside with clinical information of participants. Logistic regression analysis was used to determine the adjusted odds ratios (AOR) for the factors associated with preconception anemia.FINDINGS:Of 1248 women enrolled before conception, 36.7% (95% confidence interval (CI) 34.1-39.4) had anemia (hemoglobin <12 g/dL) and 37.6% (95% CI 34.9-40.4) had iron deficiency. For more than half of the anemic cases, iron deficiency was also diagnosed (58.8%, 95% CI 54.2-63.3). Anemia was independently associated with increased age (AOR 1.05, 95% CI 1.03-1.07), malaria infection at enrolment (AOR 2.21, 95% CI 1.37-3.58), inflammation (AOR 1.77, 95% CI 1.21-2.60) and iron deficiency (AOR 4.68, 95% CI 3.55-6.17). The odds of anemia were reduced among women with increased mid-upper arm circumference (AOR 0.90, 95% CI 0.84-0.96).CONCLUSION:Anemia among women of reproductive age before conception was prevalent in this rural setting. Increased age, iron deficiency, malaria infection and inflammation were significant risk factors associated with preconception anemia, whereas increased mid-upper arm circumference was protective against anemia. Interventions to ensure adequate iron levels as well as malaria control before conception are needed to prevent anemia before and during pregnancy and improve birth outcomes in this setting.TRIAL REGISTRATION:NCT02191683.
Background Low levels of serum 25-hydroxy vitamin D are associated with increased arterial stiffness and hypertension. Supplementation with vitamin D precursors has been proposed as a treatment option for these conditions. We examined the effect of oral cholecalciferol on arterial stiffness and blood pressure in healthy normotensive adults. Methods 40 healthy adults were randomised in this double-blinded study to either oral cholecalciferol 3000 IU/day or matching placebo and were followed for 16 weeks to examine any effects on pulse wave velocity (PWV), augmentation index (AIx), peripheral and central blood pressure and 24-hour ambulatory blood pressure. Results 22 subjects in the cholecalciferol arm and 18 subjects in the placebo arm completed the 16 weeks of follow-up. There was no difference in changes in PWV, AIx corrected for heart rate or central or peripheral blood pressure between the two groups. There was no correlation between serum 25-hydroxy vitamin D and any of these parameters. Conclusions Oral cholecalciferol 3000 IU/day does not affect arterial stiffness or blood pressure after 16 weeks of treatment in healthy normotensive adults. Trial Registration ClinicalTrials.gov NCT00952562
Preterm births accounts for roughly 9% of all births worldwide and can have detrimental or even lethal consequences for the infant. However to develop new treatment that will lower the rate of preterm births, more knowledge is required on the factors contributing to the contraction and relaxation of the myometrium. The small conductance Ca²⁺-activated potassium channel subtype 3 (SK3) has been identified in the myometrium of several species including humans, mice and rats, but with great inter species variation of the expression pattern and regulation. The aim of this study was to investigate the expression of SK3 in the uterus of rats stimulated with 17β-estradiol and progesterone in order to get an in depth understanding of the rat uterine SK3. Using immunohistochemistry SK3 was localized to the glandular and luminal endometrial lamina epitheliali. Furthermore, a weak signal was observed in the myometrium. Using Western blot the protein level of SK3 was found to increase in uteri from animals treated with 17β-estradiol, an effect that was not reflected at the mRNA level. The levels of mRNA for SK3 were significantly lower in the uterus of 17β-estradiol-treated animals than in the uterus of ovariectomized animals. We conclude that the SK channels are present in the endometrial epithelium, and possibly also in the myometrium of the rat uterus. Furthermore, the hormonal effect on SK3 caused by 17β-estradiol includes divergent regulation at mRNA and protein levels.
Background: Diagnosis of lactose intolerance is commonly based solely on the absence of the European lactose tolerance allele MCM6 -13910T, although other lactose tolerance mediating alleles exist, especially in defined African populations and in the Middle East. Therefore, a SimpleProbe assay was developed which can simultaneously detect -13910T as well as common African variants. Methods: A SimpleProbe oligonucleotide was used to discriminate between three classes of MCM6 alleles: I: Intolerance (-13910C); II: Caucasian type tolerance (-13910T); III: African/Arabian type tolerance (-13907G, -13913C, -13915G). Genotyping standards for all these alleles were constructed through PCR amplification and cloning from genomic DNA. Assay performance was tested using real-time PCR and melting curve analyses with genotyping standards as templates. Finally, the genotyping accuracy was tested using two panels: 100 individuals, previously genotyped using Sanger-sequencing and 20 individuals, previously genotyped using TaqMan analyses. Results: The assay showed a clear discrimination between gene variants conferring lactose tolerance and intolerance. Mean Tmvalues for the Caucasian alleles -13910C and -13910T were 55.3 °C and 60.8 oC respectively, whereas Tm-values for all three African/Arabian variants (-13907G, -13913C and -13915G) were in the interval of 50‑52 oC. SimpleProbe genotyping of both panels showed 100 % concordance with the results of the reference methods. Conclusions: The new SimpleProbe LightCycler assay provides a rapid, cost effective and reliable method to diagnose lactose intolerance and is especially suited for populations with African or Middle Eastern admixture.
Background: Neutrophil gelatinase-associated lipocalin (NGAL) serum values have been shown to increase in preeclampsia. The goal of the present study was to evaluate changes in urinary NGAL concentrations during uncomplicated pregnancy and in cases of preeclampsia and hypertension.Methods: Fifty-one pregnant women who developed preeclampsia and 28 diagnosed with essential or gestational hypertension were investigated for urinary NGAL concentrations during pregnancy. As controls, 100 healthy pregnant women with uncomplicated singleton pregnancies were randomly selected. Urinary NGAL as well as urinary creatinine and albumin were measured by a standardized clinical chemistry platform (ARCHITECT (R); Abbott Diagnostics, Abbott Park, IL, USA).Results: Urinary NGAL concentrations increased during pregnancy in healthy pregnant women, whereas this increase was not detected in preeclampsia. In order to correct for diuresis, spot urine concentrations were also determined as NGAL/creatinine ratio. NGAL/creatinine ratio in pregnancy week 36-38 was significantly lower in preeclampsia than in healthy pregnant women or pregnant women with hypertension. NGAL urinary concentrations did not correlate with albumin concentration in urine.Conclusions: Urinary NGAL is not a valuable early biomarker for preeclampsia.
The administration of hydroxocobalamin (OHCob), alone or with sodium thiosulfate, is a standard therapy for cyanide poisoning. OHCob is a red chromophore, and its interference with co-oximetric and colorimetric laboratory measurements has been evaluated in a few conflicting reports. The interference of OHCob was investigated in samples spiked with 10 different concentrations of OHCob (0-1500 mg/L). The concentration of 73 different analytes was measured using nine different analysers (ABL 800 Flex, Advia 1800, Advia Centaur Xp, Architect ci8200, Immulite 2500, Konelab 30i, Modular Analytics SWA, Synchron LX 20 and Vitros 5.1). All instruments yielded some results that were affected by OHCob at concentrations equivalent to a single therapeutic dose. Of the 73 different analytes, 64% showed interference on at least one instrument. Of all 187 tests performed, 47% were biased with more than 10%. Interference was generally limited to photometric assays, whereas immunological and ion-selective electrode measurements were unaffected. OHCob present in the blood after treatment for cyanide poisoning interfered with many laboratory assays in an unpredictable way, making some results invalid. Some affected tests are important in the treatment of cyanide poisoning. The interference is not solely due to wavelength, but also to chemical interaction. Without delaying the administration of OHCob, blood should, preferably, be drawn in advance, or, at least, the laboratory should be informed about the OHCob treatment. If the laboratory receives OHCob-containing samples, methods and instruments should be selected to minimize bias, and the manufacturer of the OHCob should recommend relevant precautions to customers in the package insert.
Background: We report our results for the systematic recording of all errors in a standard clinical laboratory over a 1-year period.Methods: Recording was performed using a commercial database program. All individuals in the laboratory were allowed to report errors. The testing processes were classified according to function, and errors were classified as pre-analytical, analytical, post-analytical, or service-related, and then further divided into descriptive subgroups. Samples were taken from hospital wards (38.6%), outpatient clinics (25.7%), general practitioners (29.4%), and other hospitals.Results: A total of 1189 errors were reported in 1151 reports during the first year, corresponding to an error rate of 1 error for every 142 patients, or 1 per 1223 tests. The majority of events were due to human errors (82.6%), and only a few (4.3%) were the result of technical errors. Most of the errors (81%) were pre- analytical. Of the remainder, 10% were analytical, 8% were post-analytical, and 1% was service-related. Nearly half of the errors (n=550) occurred with samples received from general practitioners or clinical hospital wards. Identification errors were relatively common when non-technicians collected blood samples.Conclusions: Each clinical laboratory should record errors in a structured manner. A relation database is a useful tool for the recording and extraction of data, as the database can be structured to reflect the work-flow at each individual laboratory. Clin Chem Lab Med 2009;47:1253-7.
OBJECTIVE:The aim of the study was to evaluate the impact of spinal cord injury on seminal plasma PSA concentration.MATERIAL:Semen obtained from normal controls (n = 20) and patients (n = 16) with spinal cord injury.RESULTS:The concentration of prostate specific antigen in seminal plasma depended on the level of spinal cord injury, with significantly lower concentrations in patients with spinal cord lesions below T7 compared to both normal age-matched controls (P = 0.007) and patients with spinal cord injuries at or above T7 (P = 0.017).CONCLUSIONS:The results add to the previously reported observations of the possible impact of neurogenic stimulation on prostate activity. More studies of neurogenic stimulation in prostate growth and development are warranted to further elucidate the possible impact of neurogenic factors in the development of prostatic diseases.
The regulation of cholecystokinin and somatostatin expression by vitamin D and cyclic AMP in the rat medullary thyroid carcinoma cell line CA-77 was investigated. Treatment with 100 nmol/l vitamin D did not affect cholecystokinin mRNA and peptide concentrations significantly; somatostatin mRNA level increased 6 times and the somatostatin peptide concentration increased 2-fold after 5 days of drug treatment. Under the same experimental conditions cyclic AMP increased cholecystokinin mRNA level 4.5 times and the cellular cholecystokinin-peptide concentration 2-fold; somatostatin mRNA and peptide concentrations were not significantly changed. Cyclic AMP stimulated peptide secretion from the cells were not affected by vitamin D, but cyclic AMP mediated increase in CCK peptide concentration was significantly inhibited by vitamin D (p < 0.05).
Four cases of endocarditis due toKingella kingae are described in compromised patients. All had primary heart disease, and two had systemic lupus erythematosis and congenital heart defect respectively, in addition. Confirmation ofKingella kingae was made in one case at autopsy. The literature on 11 cases of endocarditis, 2 bacteremia, 4 osteomyelitis, 5 septic arthritis and 1 intervertebral disc infection, all caused byKingella kingae, is reviewed. Our findings confirm that the organism is of low pathogenicity. Children may be predisposed to infection withKingella kingae.
Kingella kingae is a rarely isolated opportunistic pathogen in the family Neisseriaceae. Thirteen strains of this organism, including six strains isolated in Denmark, were characterized. They formed a homogeneous group of small, non-motile, fastidious Gram-negative rods which were beta-haemolytic, oxidase positive, catalase negative and saccharolytic. Acid was produced for glucose and maltose. Growth was most pronounced aerobically but corroding colonies increased considerably in size during anaerobic incubation.