Cardiovascular blood flow is highly complex and incompletely understood. Blood flow patterns are expected to influence the opening and closing of normal and prosthetic heart valves, the efficiency of cardiac filling and ejection, and the resistance to thrombus formation within the heart. Conventional diagnostic techniques are poorly suited to the study of the three-dimensional (3D) blood flow patterns in the heart chambers and large vessels. Noninvasive methods have also been inadequate in studying intracardiac pressure differences, which are the driving force of flow and are critical in the evaluation of many cardiovascular abnormalities.This thesis focuses on the development of non-invasive methods for analysis of 3D cardiovascular blood flow. Simultaneous study of cardiovascular fluid dynamics allowed knowledge exchange across the two disciplines, facilitating the development process and broadening the applicability of the methods.A time-resolved 3D phase-contrast Magnetic Resonance lrnaging (MRI) technique was used to acquire the velocity vector field in a 3D volume encompassing the entire heart or a large vessel. Cardiovascular blood flow patterns were visualized by use of particle traces, which revealed, for instance, vortical flow patterns in the left atrium.By applying the Navier-Stokes equation along a user-defined line in the 3D velocity vector field, the relative pressure could be obtained as an excellent supplement to the flow pattern visualization. Using a delineation of the blood pool, the time-varying 3D relative pressure field in the human left ventricle was obtained from the velocity field by use of the pressure Poisson equation.A delineation of the heart muscle, a task that is almost impossible to perform on 3D MRI either automatically or manually, was also achieved by usage of particle traces. This segmentation allows automatic calculation of the 3D relative pressure field, as well as calculation of well-established parameters such as ventricle volume and mass.Simultaneous 3D assessment of cardiovascular pressure and flow phenomena throughout the cardiac cycle offers an opportunity to expand our understanding of the basic determinants of time-varying flow in healthy and sick hearts, with the potential for improving our methods for diagnosis, medical treatment and surgical correction of cardiovascular diseases.
We propose a robust approach for multimodality segmentation of the cardiac left ventricle. The method is based on the concept of deformable models, but extended with an enhanced and fast edge detec ...
PURPOSE:The combination of quickly rotating C-arm gantry with digital flat panel has enabled the acquisition of three-dimensional data (3D) in the interventional suite. However, image quality is still somewhat limited since the hardware has not been optimized for CT imaging. Adaptive anisotropic filtering has the ability to improve image quality by reducing the noise level and therewith the radiation dose without introducing noticeable blurring. By applying the filtering prior to 3D reconstruction, noise-induced streak artifacts are reduced as compared to processing in the image domain. METHODS:3D anisotropic adaptive filtering was used to process an ensemble of 2D x-ray views acquired along a circular trajectory around an object. After arranging the input data into a 3D space (2D projections + angle), the orientation of structures was estimated using a set of differently oriented filters. The resulting tensor representation of local orientation was utilized to control the anisotropic filtering. Low-pass filtering is applied only along structures to maintain high spatial frequency components perpendicular to these. The evaluation of the proposed algorithm includes numerical simulations, phantom experiments, and in-vivo data which were acquired using an AXIOM Artis dTA C-arm system (Siemens AG, Healthcare Sector, Forchheim, Germany). Spatial resolution and noise levels were compared with and without adaptive filtering. A human observer study was carried out to evaluate low-contrast detectability. RESULTS:The adaptive anisotropic filtering algorithm was found to significantly improve low-contrast detectability by reducing the noise level by half (reduction of the standard deviation in certain areas from 74 to 30 HU). Virtually no degradation of high contrast spatial resolution was observed in the modulation transfer function (MTF) analysis. Although the algorithm is computationally intensive, hardware acceleration using Nvidia's CUDA Interface provided an 8.9-fold speed-up of the processing (from 1336 to 150 s). CONCLUSIONS:Adaptive anisotropic filtering has the potential to substantially improve image quality and/or reduce the radiation dose required for obtaining 3D image data using cone beam CT.
Purpose: To assess in vitro the three-dimensional mean velocity field and the extent and degree of turbulence intensity (TI) in different prosthetic heart valves using a generalization of phase-contrast MRI (PC-MRI).Materials and Methods: Four 27-mm aortic valves (Bjork-Shiley Monostrut tilting-disc, St. Jude Medical Standard bileaflet, Medtronic Mosaic stented and Freestyle stentless porcine valve) were tested under steady inflow conditions in a Plexiglas phantom. Three-dimensional PC-MRI data were acquired to measure the mean velocity field and the turbulent kinetic energy (TKE), a direction-independent measure of TI.Results: Velocity and TI estimates could be obtained up and downstream of the valves, except where metallic structure in the valves caused signal void. Distinct differences in the location, extent, and peak values of velocity and TI were observed between the valves tested. The maximum values of TKE varied between the different valves: tilting disc, 100 J/m(3); bileaflet, 115 J/m(3); stented, 200 J/m(3); stentless, 145 J/m(3).Conclusion: The TI downstream from a prosthetic heart valve is dependent on the specific valve design. Generalized PC-MRI can be used to quantify velocity and TI downstream from prosthetic heart valves, which may allow assessment of these aspects of prosthetic valvular function in postoperative patients.
P>Background:Myocardial dynamics are three-dimensional (3D) and time-varying. Cineradiography of surgically implanted makers in animals or patients is accurate for assessing these events, but this invasive method potentially alters myocardial motion. The aim of the study was to quantify myocardial motion using magnetic resonance imaging (MRI) and hence to provide a non-invasive approach to characterize 3D myocardial dynamics.Methods:Myocardial motion was quantified in ten normal volunteers by tracking the Lagrangian motion of individual points (i.e. virtual markers), based on time-resolved 3D phase-contrast MRI data and Fourier tracking. Nine points in the myocardium were tracked over the entire cardiac cycle, allowing a wire frame model to be generated and systolic and diastolic events identified.Results:Radius of curvature of the left ventricular (LV) wall was calculated from the virtual markers; the ratio between the anterior-posterior (AP) and septal-lateral (SL) walls in the LV shows an oval shape of the apical short axis plane at end systole (ES) and more circular at end diastole (ED). The AP/SL ratio for the basal plane shows an oval shape at ES and ED. We found that the rotation of the basal plane in ES was less compared to the apical plane [-2 center dot 0 +/- 2 center dot 2 versus 4 center dot 1 +/- 2 center dot 6 degrees (P < 0 center dot 005)]. The apical plane rotated counter clock wise as viewed from the apex.Conclusion:This new non-invasive tool, despite current limitations in temporal and spatial resolution, may provide a comprehensive set of virtual myocardial markers throughout the entire LV without the confounding effects introduced by surgical implantation.
Generating 3-D images of the heart during interventional procedures is a significant challenge. In addition to real time fluoroscopy, angiographic C-arm systems can also now be used to generate 3-D/4-D CT images on the same system. One protocol for cardiac CT uses ECG triggered multisweep scans. A 3-D volume of the heart at a particular cardiac phase is then reconstructed by applying Feldkamp (FDK) reconstruction to the projection images with retrospective ECG gating. In this work we introduce a unified framework for heart motion estimation and dynamic cone-beam reconstruction using motion corrections. The benefits of motion correction are 1) increased temporal and spatial resolution by removing cardiac motion which may still exist in the ECG gated data sets and 2) increased signal-to-noise ratio (SNR) by using more projection data than is used in standard ECG gated methods. Three signal-enhanced reconstruction methods are introduced that make use of all of the acquired projection data to generate a 3-D reconstruction of the desired cardiac phase. The first averages all motion corrected back-projections; the second and third perform a weighted averaging according to 1) intensity variations and 2) temporal distance relative to a time resolved and motion corrected reference FDK reconstruction. In a comparison study seven methods are compared: nongated FDK, ECG-gated FDK, ECG-gated, and motion corrected FDK, the three signal-enhanced approaches, and temporally aligned and averaged ECG-gated FDK reconstructions. The quality measures used for comparison are spatial resolution and SNR. Evaluation is performed using phantom data and animal models. We show that data driven and subject-specific motion estimation combined with motion correction can decrease motion-related blurring substantially. Furthermore, SNR can be increased by up to 70% while maintaining spatial resolution at the same level as is provided by the ECG-gated FDK. The presented framework provides excellent image quality for cardiac C-arm CT.
Phase-contrast magnetic resonance imaging has the ability to accurately measure blood flow and myocardial velocities in the human body. Unwanted spatially varying phase offsets are, however, always ...
To estimate regional myocardial strain rate, with reduced sensitivity to noise and velocities outside the region of interest, and provide a visualization of the spatial variation of the obtained tensor field within the myocardium.
BACKGROUND Cardiac computed tomography (CT) is commonly used to visualize Left atrial (LA) anatomy for ablation of atrial fibrillation. We have developed a new imaging technique that allows acquisition and visualization of three-dimensional (3D) cardiac images in the catheter Lab.OBJECTIVE We sought to compare LA and pulmonary vein (PV) dimensions acquired using gated multisweep rotational fluoroscopy (C-arm CT) system and muttislice computed tomography (MSCT) in an in vivo porcine model.METHODS A Siemens AXIOM Artis dTA C-arm system (Siemens AG, Medical Solutions) was modified to allow acquisition of four bidirectional sweeps during synchronized acquisition of the electrocardiogram signal to allow retrospective gating. C-arm CT image volumes were then reconstructed. Gated MSCT (SOMATOM Sensation 16 and 64, Siemens AG, Medical Solutions) and C-arm CT images were acquired in six animals. The two main PV diameters were measured in orthogonal axes. LA volumes were calculated. C-arm CT measurements were compared with the MSCT measurements.RESULTS The average PV diameters using the C-arm CT were 2.24 x 1.35 cm, versus 2.27 x 1.38 cm for CT. The average difference was 0.034 cm (1.9%) between the C-arm CT and standard CT. The average LA volume using MSCT was 49.1 +/- 12.7 cm(3), as compared with 51.0 +/- 8.7 cm(3) obtained by the C-arm CT. The average difference between the C-arm CT and the MSCT was 1.9 cm(3) (3.7%). There were no significant differences in either the PV or LA measurements.CONCLUSIONS Visualization of 3D cardiac anatomy during ablation procedures is possible and highly accurate. The 3D cardiac reconstructions acquired during ablation procedures will be valuable for procedural planning and guidance.
Multidimensional imaging resolving both the cardiac and respiratory cycles simultaneously has the potential to describe important physiological interdependences between the heart and pulmonary processes. A fully five-dimensional acquisition with three spatial and two temporal dimensions is hampered, however, by the long acquisition time and low spatial resolution. A technique is proposed to reduce the scan time substantially by extending the k-t BLAST framework to two temporal dimensions. By sampling the k-t space sparsely in a lattice grid, the signal in the transform domain, x-f space, can be densely packed, exploiting the fact that large regions in the field of view have low temporal bandwidth. A volumetric online prospective triggering approach with full cardiac and respiratory cycle coverage was implemented. Retrospective temporal interpolation was used to refine the timing estimates for the center of k-space, which is sampled for all cardiac and respiratory time frames. This resulted in reduced reconstruction error compared with conventional k-t BLAST reconstruction. The k-t2 BLAST technique was evaluated by decimating a fully sampled five-dimensional data set, and feasibility was further demonstrated by performing sparsely sampled acquisitions. Compared to the fully sampled data, a fourfold improvement in spatial resolution was accomplished in approximately half the scan time.
Cardiac C-arm CT is a promising technique that enables 3D cardiac image acquisition and real-time fluoroscopy on the same system. Retrospective ECG gating techniques have already been adapted from clinical cardiac CT that allow 3D reconstruction using retrospectively gated projection images of a multi-sweep C-arm CT scan according to the desired cardiac phase. However, it is known that retrospective gating of projection data does not provide an optimal signal-to-noise-ratio (SNR) since the measured projection data is only partially considered during the reconstruction. In this work we introduce a new reconstruction technique for cardiac C-arm CT that provides increased SNR by including additional corrected and resampled filtered back-projections (FBP) from temporal windows outside of the targeted reconstruction phase. We take advantage of several motion corrected FDK-like reconstructions of the subject to increase SNR. In the presented results, using in vivo data from an animal model, the SNR could be increased by approximately 30 percent.
Studies of myocardial motion using magnetic resonance imaging usually require multiple breath holds and several methods have been proposed in order to reduce the scan time. Rapid imaging using k-t BLAST has gained much attention with its high reduction factors and image quality. Temporal smoothing, however, may reduce the accuracy when assessing cardiac function. In the present work, a modified reconstruction filter is proposed, that preserves more of the high temporal frequencies. Artificial decimation of a fully sampled data set was used to evaluate the reconstruction filter. Compared to the conventional k-t BLAST reconstruction, the modified filter produced images with sharper temporal delineation of the myocardial walls. Quantitative analysis by means of regional velocity estimation showed that the modified reconstruction filter produced more accurate velocity estimations.