The pKa values in water and in dilute surfactant solution for 15 ring-substituted phenyl P1 pyrrolidino phosphazenes PhN=P(NC4H8)3 and the phenyl P1 dimethylamino phosphazene PhN=P(NMe2)3 previously studied in acetonitrile (AN) and tetrahydrofuran (THF) are reported. The nonionic surfactant Tween 20 was used for the basicity measurements of some compounds to overcome the solubility problems. Measurements with a control group of phosphazenes in both media were used to validate the use of the obtained pKa values as estimates of aqueous values. The pK(a) values of the studied phosphazenes in aqueous medium vary from 6.82 (2,6-dinitro-) to 12.00 (4-dimethylamino-). The basicity span is 5.18 pKa units. The aqueous pKa values of the P1 phosphazenes were correlated with the respective basicity data in AN and THF and from these correlations the pK(a) values in water for the parent compounds HN=P(NC4H8)3 and HN=P(NMe2)3 were estimated as 13.9 and 13.3. Also a comparison of the basicity of phosphazenes and some guanidines, amines and pyridines was made. In water the parent phosphazenes and guanidines are the strongest of all the groups of bases studied. In AN and THF the parent phosphazenes are clearly the strongest bases followed by guanidines, amines and pyridines which are bracketed between the basicities of phenyl phosphazenes. In the gas phase the phosphazenes for which data are available are clearly more basic than the other compounds referred to here. Comparison of the basicity data of P1 phosphazenes and some guanidines confirms earlier conclusions about the partly ylidic character of the N=P double bond.
The difficulties in estimating uncertainty of pKa values determined in nonaqueous media are reviewed and two different uncertainty estimation approaches are presented and applied to the pKa values of the compounds on a previously established self-consistent spectrophotometric basicity scale in acetonitrile. One approach is based on the ISO GUM methodology (the “ISO GUM” approach) and involves careful analysis of the uncertainty sources and quantifying the respective uncertainty components. The second approach is based on the standard-deviation-like statistical parameter that has been used for characterization of the consistency of the scale (the “statistical” approach). It is demonstrated that the ISO GUM approach somewhat overestimates the uncertainty. The statistical approach is based on long-term within-laboratory statistical data and it is demonstrated that it underestimates the uncertainty. In particular it neglects the laboratory bias effects that are taken into account at least to some extent by the ISO GUM approach. Thus, together these two approaches allow to “bracket” the uncertainties of the pKa values on the scale. The uncertainties of the pKa values are defined in two different ways. Definition (a) includes the uncertainty of the pKa of the reference base (anchor base of the scale) pyridine. Definition (b) excludes it. It is demonstrated that both definitions have their virtues. Definition (a) leads to the uncertainty ranges of 0.12–0.22 and 0.12–0.14 pKa units at standard uncertainty level for different bases using the ISO GUM and statistical approach, respectively. Definition (b) leads to the uncertainty ranges of 0.04–0.19 and 0.02–0.08 pKa units, respectively. The uncertainty of the pKa of a given base is dependent on the quality of the measurements involved and on the distance from the reference base on the scale. The importance of the correlation between the pKa values of bases belonging to the same scale is stressed.
AbstractChemInform is a weekly Abstracting Service, delivering concise information at a glance that was extracted from about 200 leading journals. To access a ChemInform Abstract, please click on HTML or PDF.
An overview is given of the most important uncertainty sources that affect analytical UV-Vis spectrophotometric measurements. Altogether, eight uncertainty sources are discussed that are expected to have influence in chemical analysis. It is demonstrated that the well-known intrinsic (or "physical") sources of uncertainty that originate from the instrument itself (repeatability of spectrophotometer reading, spectrophotometer drift, stray light, etc.) often have significantly lower contributions to the combined uncertainty of the result than the "chemical" sources of uncertainty that originate from the object under study (interference from the constituents of the matrix, decomposition of the photometric complex, etc.). Although selectivity of a photometric procedure is often considered more a validation topic than an uncertainty topic, it is very often important to include it also in the uncertainty budget.Usually the most difficult part of uncertainty estimation of a chemical measurement result is to evaluate the magnitude of the actual uncertainty components, especially the chemical ones. For most of the uncertainty sources discussed in this paper, approaches for their evaluation are given. A generic uncertainty budget for absorbance is presented.
For the first time, the self-consistent spectrophotometric acidity scale of neutral Brønsted acids in acetonitrile (AN) spanning 24 orders of magnitude of acidities is reported. The scale ranges from pK(a) 3.7 to 28.1 in AN. The scale includes 93 acids that are interconnected by 203 relative acidity measurements (DeltapK(a) measurements) and contains compounds with gradually changing acidities, including representatives from all of the conventional families of OH (alcohols, phenols, carboxylic acids, sulfonic acids), NH (anilines, diphenylamines, disulfonimides), and CH acids (fluorenes, diphenylacetonitriles, phenylmalononitriles). The CH acids were particularly useful in constructing the scale because they do not undergo homo- or heteroconjugation processes and their acidities are rather insensitive to traces of water in the medium. The scale has been fully cross-validated: the relative acidity of any two acids on the scale can be found by combining at least two independent sets of DeltapK(a) measurements. The consistency standard deviation of the scale is 0.03 pK(a) units. Comparison of acidities in many different media has been carried out, and the structure-acidity relations are discussed. The large variety of the acids on the scale, its wide span, and the quality of the data make the scale a useful tool for further acidity studies in acetonitrile.
The experience of working under an ISO 17025 compliant quality system in a university environment is described in the example of the Testing Centre of University of Tartu. University-specific features of the quality system include that the Testing Centre acts as the “quality system server” for other units of the university and graduate students participate in the work carried out under the quality system. The benefits for the university and the graduate students are discussed. It is concluded that implementation of an ISO 17025 compatible quality system in a university is fully accomplishable and gives significant added value to the university by helping to destroy the ivory tower perception about universities and by introducing real-world flavour into the studies and broaden the minds (quality awareness) of the students.
The earlier compiled self-consistent spectrophotometric basicity scale in acetonitrile (AN) was expanded to range from 3.8 to 32.0 pK(a) units, that is 28 orders of magnitude. Altogether 54 new relative basicity measurements (DeltapK(a) measurements) were carried out and 37 new compounds were introduced to the scale (it now includes altogether 89 bases). The relative basicity of any two bases in the scale can be obtained by combining at least two independent sets of measurements. Multiple overlapping measurements make the results more reliable. The overall consistency (as defined earlier) of the measurements is s = 0.03 pK(a) units. Thorough analysis of all of our experimental data (DeltapK(a) values of this and earlier works) and experimental pK(a) data in AN available in the literature (works from the groups of Coetzee and Padmanabhan, Kolthoff and Chantooni, Jr., the Schwesinger group, Bren' et al. and some others, altogether 19 papers) was carried out. On the basis of this analysis the anchor point of the scale-pyridine-was shifted upward by 0.20 pK(a) units thereby also revising the absolute pK(a) values of all the bases on the scale. This way very good agreement between our relative data and the absolute pK(a) values of the abovementioned authors was obtained. The revised basicity scale was interconnected with the earlier published self-consistent acidity scale by DeltapK(a) measurements between acids and bases. The rms deviation between the directly measured DeltapK(a) values and the absolute pK(a) values of the compounds was 0.10 pK(a) units.
A procedure for estimation of measurement uncertainty of photometric analysis based on the ISO GUM method is presented. Two variations of the procedure—for the calibration graph and the standard addition method, respectively—are discussed. The variations are based on mathematical models involving 64 and 80 input quantities, respectively. The uncertainty of the result strongly depends on changes in experimental details. These dependencies are explored for a practical example of determination of the iron content of aluminum. The importance of taking uncertainty from sample preparation into account in uncertainty estimation is stressed. The number of effective degrees of freedom is calculated and discussed. The examples are available as GUM Workbench files in the Electronic Supplementary Material.