The 4-biphenylnitrenium ion (BPN), a reactive metabolic intermediate of the tobacco smoke carcinogen 4-aminobiphenyl (4-ABP), can react with nucleophilic sulfanyl groups in glutathione (GSH) as well as in proteins. The main site of attack of these S-nucleophiles was predicted using simple orientational rules of aromatic nucleophilic substitution. Thereafter, a series of presumptive 4-ABP metabolites and adducts with cysteine were synthesized, namely, S-(4-amino-3-biphenyl)cysteine (ABPC), N-acetyl-S-(4-amino-3-biphenyl)cysteine (4-amino-3-biphenylmercapturic acid, ABPMA), S-(4-acetamido-3-biphenyl)cysteine (AcABPC), and N-acetyl-S-(4-acetamido-3-biphenyl)cysteine (4-acetamido-3-biphenylmercapturic acid, AcABPMA). Then, globin and urine of rats dosed with a single ip dose of 4-ABP (27 mg/kg b.w.) was analyzed by HPLC-ESI-MS2. ABPC was identified in acid-hydrolyzed globin at levels of 3.52 ± 0.50, 2.74 ± 0.51, and 1.25 ± 0.12 nmol/g globin (mean ± S.D.; n = 6) on days 1, 3, and 8 after dosing, respectively. In the urine collected on day 1 (0-24 h) after dosing, excretion of ABPMA, AcABPMA, and AcABPC amounted to 1.97 ± 0.88, 3.09 ± 0.75, and 3.69 ± 1.49 nmol/kg b.w. (mean ± S.D.; n = 6), respectively. On day 2, excretion of the metabolites decreased by one order of magnitude followed by a slower decrease on day 8. Regarding the possible formation of AcABPC from ABPC, N-acetylation of the amino group at the biphenyl moiety prior to that at cysteine appears to be very unlikely. Thus, the structure of AcABPC indicates the involvement of N-acetyl-4-biphenylnitrenium ion (AcBPN) and/or its reactive ester precursors in in vivo reactions with GSH and protein-bound cysteine. ABPC in globin might become an alternative biomarker of the dose of toxicologically relevant metabolic intermediates of 4-ABP.
Biomonitoring of human exposure to reactive electrophilic chemicals such as ethylene oxide (EO) has been commonly based on the determination of adducts with N-terminal valine in blood protein globin, but a systematic search has also been undertaken to find surrogate markers enabling non-invasive sampling. Recently, N-(2-hydroxyethyl)-L-valyl-L-leucine (HEVL) has been identified as an ultimate cleavage product of EO-adducted globin in the urine of occupationally exposed workers. Herein, full validation of the analytical procedure consisting of solid-phase extraction of HEVL from urine samples (2 mL) followed by high-performance liquid chromatography-electrospray ionization-high-resolution mass spectrometry determination using deuterium-labeled HEVL as an internal standard (IS) is described. Method limit of quantitation is 0.25 ng/mL, and its selectivity is excellent as demonstrated by the invariable ratio of the qualifier and quantifier ion intensities across diverse urine samples and synthetic standard. The linear calibration model was applicable over the whole concentration range tested (0.25-10 ng/mL). The method accuracy assessed as a recovery of HEVL using a spiking experiment was 98-100%. Within-day precision of the method ranged from 1.8% to 3.0%, while the results from consecutive analytical runs conducted within 1 week or within 10-150 weeks differed in the range of 2.2-9.7%. The stability study on urine samples (-20 degrees C up to 3 years, freeze-and-thaw up to 10 cycles) as well as on aqueous solutions (5 degrees C up to 4 months) indicated no relevant changes in HEVL concentration (<= 4%) over the time tested. Analytical responses of both HEVL and IS correlated with urinary creatinine as an index of matrix composition, but this matrix effect was mostly eliminated using the HEVL/IS peak area ratio, attaining the IS-normalized relative matrix effect <3%. In conclusion, the method complied successfully with the bioanalytical method validation criteria, making it a reliable tool for HEVL determination in human biomonitoring.
A simple environmentally friendly one-step synthetic procedure was developed for S- and N-methylcarbamoylation of amino acids and their derivatives in buffered aqueous solutions. N-Succinimidyl N-methylcarbamate (SNMC) and N,S-dimethylthiocarbamate (DMTC) were used as synthetic equivalents to replace highly hazardous methyl isocyanate (MIC). SNMC reacted rapidly in both S- and N-methylcarbamoylations affording nearly quantitative conversions (>97 %) of all tested compounds after 2–3 h at 50 °C at pH 8.2 and 9.5–10 for S- and N-methylcarbamoylations, respectively. Under the same conditions, DMTC reacted more slowly (48 h for N-methylcarbamoylations) but with some polar amino acids it provided products of higher purity than SNMC. Similarly, N-trideuteriomethyl-S-methylthiocarbamate (DMTC-d3) was used to synthesize Nα- and Nε-trideuteriomethylcarbamoyl derivatives of valine and lysine, respectively. Prepared compounds will be used in toxicological research as authentic standards in the analyses for protein adducts derived from MIC or its metabolic precursor, N,N-dimethylformamide.
Ethylene oxide (EO), a carcinogenic chemical used as an industrial intermediate and sterilant, forms covalent adducts with DNA and proteins. The adduct with N-terminal valine [N-(2-hydroxyethyl)-l-valine, HEV] in blood protein globin has been employed as a principal biomarker of cumulative exposures to EO. However, as sampling of blood is inconvenient in routine occupational health practice, a non-invasive alternative to globin analysis has been investigated. Following identification of N-(2-hydroxyethyl)-l-valyl-l-leucine (HEVL) as ultimate cleavage product of EO-adducted globin excreted in the rat urine, here we report for the first time on the presence of HEVL in the urine of humans. In 18 sterilization workers, urinary HEVL ranged from 0.67 to 11.98 μg/g creatinine (mean ± SD: 5.04 ± 3.14 μg/g creat) and correlated with HEV: HEVL (μg/g creat) = 0.833 HEV (nmol/g globin) + 1.19 (R2 = 0.45). As unexpectedly high levels of urinary HEVL were found also in controls (mean ± SD: 0.97 ± 0.37 μg/g creat, n = 32), HEVL is not proposed for the accurate assessment of sub-ppm exposures to EO. On the other hand, non-invasive sampling and facile work-up procedure predetermine HEVL for screening purposes to identify subjects approaching to or exceeding occupational exposure limit for EO (1.8 mg/m3) to be re-examined by the more sensitive reference analysis for HEV.
Novel aminonaphthylcysteine (ANC) adducts, formed via naphthylnitrenium ions and/or their metabolic precursors in the biotransformation of naphthylamines (NA) and nitronaphthalenes (NN), were identified and quantified in globin of rats dosed intraperitoneally with 0.16 mmol/kg b.w. of 1-NA, 1-NN, 2-NA and 2-NN. Using HPLC-ESI-MS2 analysis of the globin hydrolysates, S-(1-amino-2-naphthyl)cysteine (1A2NC) together with S-(4-amino-1-naphthyl)cysteine (4A1NC) were found in rats given 1-NA or 1-NN, and S-(2-amino-1-naphthyl)cysteine (2A1NC) in those given 2-NA or 2-NN. The highest level of ANC was produced by the most mutagenic and carcinogenic isomer 2-NA (35.8 ± 5.4 nmol/g globin). The ratio of ANC adduct levels for 1-NA, 1-NN, 2-NA and 2-NN was 1:2:100:3, respectively. Notably, the ratio of 1A2NC:4A1NC in globin of rats dosed with 1-NA and 1-NN differed significantly (2:98 versus 16:84 respectively), indicating differences in mechanism of the adduct formation. Moreover, aminonaphthylmercapturic acids, formed via conjugation of naphthylnitrenium ions and/or their metabolic precursors with glutathione, were identified in the rat urine. Their amounts excreted after dosing rats with 1-NA, 1-NN, 2-NA and 2-NN were in the ratio 1:100:40:2, respectively. For all four compounds tested, haemoglobin binding index for ANC was several-fold higher than that for the sulphinamide adducts, generated via nitrosoarene metabolites. Due to involvement of electrophilic intermediates in their formation, ANC adducts in globin may become toxicologically more relevant biomarkers of cumulative exposure to carcinogenic or non-carcinogenic arylamines and nitroarenes than the currently used sulphinamide adducts.
In October–November, 2020, a Working Group of 20 scientists from ten countries met remotely at the invitation of the International Agency for Research on Cancer (IARC) to finalise their evaluations of the carcinogenicity of acrolein, crotonaldehyde, and arecoline. Acrolein was classified as “probably carcinogenic to humans” (Group 2A) on the basis of “sufficient” evidence of carcinogenicity in experimental animals and “strong” mechanistic evidence. Crotonaldehyde and arecoline were classified as “possibly carcinogenic to humans” (Group 2B) on the basis of “strong” mechanistic evidence. For all three agents, the evidence regarding cancer in humans was “inadequate”; no data were available for arecoline, and the few available studies of cancer in humans for acrolein and crotonaldehyde were generally small or uninformative. These assessments will be published in volume 128 of the IARC Monographs. 1 International Agency for Research on Cancer. Volume 128: acrolein, crotonaldehyde, and arecoline. IARC Working Group. Lyon, France; Oct 29–Nov 13, 2020; IARC Monogr Identif Carcinog Hazards Hum (in press). Google Scholar
Chemicals can be dangerous. Legislative measures are needed to minimize the risk arising from manipulation, uses and abuses of toxic or otherwise dangerous chemicals. In this review current European chemical legislation is shortly described and some of its aspects, such as excessive formalism, narrowly defined categories of toxicity and of other hazards are criticized. It is pointed out that information on dangerous chemicals provided by European Chemical Agency, as well as that found in a typical Safety Data Sheet, is of limited practical use and can often be misleading. Attempts to exclude liability for any possible misuse of chemical products often lead to exaggeration of hazardous properties and to excessively prudent precautionary measures. Excessive warnings may paradoxically lead users to neglect even the well-founded ones thus underestimating serious risks. Absolute safety is conceivable only in a state of absolute immobility.
Ethylene oxide (EO), a genotoxic industrial chemical and sterilant, forms covalent adducts with DNA and also with nucleophilic amino acids in proteins. The adduct with N-terminal valine in globin [N-(2-hydroxyethyl)valine (HEV)] has been used in biomonitoring of cumulative exposures to EO. Here we studied in rats the fate of EO-adducted N-termini of globin after life termination of the erythrocytes. Rat erythrocytes were incubated with EO to produce the HEV levels in globin at 0.4–13.2 µmol/g as determined after acidic hydrolysis. Alternative hydrolysis of the isolated globin with enzyme pronase afforded N-(2-hydroxyethyl)-l-valyl-l-leucine (HEVL) and N-(2-hydroxyethyl)-l-valyl-l-histidine (HEVH), the EO-adducted N-terminal dipeptides of rat globin α- and β-chains, respectively. The ratio of HEVL/HEVH (1:3) reflected higher reactivity of EO with the β-chain. The EO-modified erythrocytes were then given intravenously to the recipient rats. HEVL and HEVH were found to be the ultimate cleavage products excreted in the rat urine. Finally, rats were dosed intraperitoneally with EO, 50 mg/kg. Herein, the initial level of globin-bound HEVL (11.7 ± 1.3 nmol/g) decreased almost linearly over 60 days corresponding to the life span of rat erythrocytes. Daily urinary excretion of HEVL was almost constant for 30–40 days, decreasing faster in the subsequent phase of elimination. Recoveries of the total urinary HEVL from its globin-bound form were 84 ± 6% and 101 ± 17% after administrations of EO and the EO-modified erythrocytes, respectively. In conclusion, urinary HEVL appears to be a promising novel non-invasive biomarker of human exposures to EO.
Ethylene oxide (EO), an industrial intermediate and gaseous sterilant for medical devices, is carcinogenic to humans, which warrants minimization of exposure in the workplaces. The principal analytical strategy currently used in biomonitoring of exposure to EO consists in the conversion of N-(2-hydroxyethyl) adduct at the N-terminal valine (HEV) in globin to a specific thiohydantoin derivative accessible to GC-MS analysis (modified Edman degradation, MED). Though highly sensitive, the method is laborious and, at least in our hands, not sufficiently robust. Here we developed an alternative strategy of HEV determination based on acidic hydrolysis (AH) of globin followed directly by HPLC-ESI-MS2 analysis. Limit of quantitation is ca. 25 pmol HEV/g globin. Comparative analyses of globin samples from EO-exposed workers by both the AH-based and MED-based methods provided results that correlated well with each other (R-2 > 0.95) but those obtained with AH were significantly more accurate (according to external quality control programme G-EQUAS) and repeatible (5% and 6% for intra-day and between-day analyses, respectively). In conclusion, the new AH-based method surpassed MED being similarly sensitive, much less laborious and more reliable, thus applicable as an effective tool for biomonitoring of EO in exposure control and risk assessment.
When the above article was first published online, the below authors were incorrectly affiliated to National Institute of Mental, Health, Klecany, Czech Republic. Igor Linhart Michal Himl Lubomı́r Váňa Michal Vetýška Also two authors, Tomáš Pálenı́ček and Eva Lhotková, were incorrectly affiliated to Department of Organic Chemistry, Faculty of Chemical Technology, University of Chemistry and Technology, Prague, Czech Republic.
3-Nitrobenzanthrone (3-NBA), a potent environmental mutagen and carcinogen, is known to be activated in vivo to 3-benzanthronylnitrenium ion which forms both NH and C2-bound adducts with DNA and also reacts with glutathione giving rise to urinary 3-aminobenzanthron-2-ylmercapturic acid. In this study, acid hydrolysate of globin from rats dosed intraperitoneally with 3-NBA was analysed by HPLC/MS to identify a novel type of cysteine adduct, 3-aminobenzanthron-2-ylcysteine (3-ABA-Cys), confirmed using a synthesised standard. The 3-ABA-Cys levels in globin peaked after single 3-NBA doses of 1 and 2 mg/kg on day 2 to attain 0.25 and 0.49 nmol/g globin, respectively, thereafter declining slowly to 70–80% of their maximum values during 15 days. After dosing rats for three consecutive days with 1 mg 3-NBA/kg a significant cumulation of 3-ABA-Cys in globin was observed. 3-ABA-Cys was also found in the plasma hydrolysate. Herein, after dosing with 1 and 2 mg 3-NBA/kg the adduct levels peaked on day 1 at 0.15 and 0.51 nmol/ml plasma, respectively, thereafter declining rapidly to undetectable levels on day 15. In addition, sulphinamide adducts were also found in the exposed rats, measured indirectly as 3-aminobenzanthrone (3-ABA) split off from globin by mild acid hydrolysis. Levels of both types of adducts in the globin samples parallelled very well with 3-ABA/3-ABA-Cys ratio being around 1:8. In conclusion, 3-ABA-Cys is the first example of arylnitrenium-cysteine adduct in globin representing a new promising class of biomarkers to assess cumulative exposures to aromatic amines, nitroaromatics and heteroaromatic amines.