Radiation dose is central to much of radiobiological research. Precision and accuracy of dose measurements and reporting of the measurement details should be sufficient to allow the work to be interpreted and repeated and to allow valid comparisons to be made, both in the same laboratory and by other laboratories. Despite this, a careful reading of published manuscripts suggests that measurement and reporting of radiation dosimetry and setup for radiobiology research is frequently inadequate, thus undermining the reliability and reproducibility of the findings. To address these problems and propose a course of action, the National Cancer Institute (NCI), the National Institute of Allergy and Infectious Diseases (NIAID), and the National Institute of Standards and Technology (NIST) brought together representatives of the radiobiology and radiation physics communities in a workshop in September, 2011. The workshop participants arrived at a number of specific recommendations as enumerated in this paper and they expressed the desirability of creating dosimetry standard operating procedures (SOPs) for cell culture and for small and large animal experiments. It was also felt that these SOPs would be most useful if they are made widely available through mechanism(s) such as the web, where they can provide guidance to both radiobiologists and radiation physicists, be cited in publications, and be updated as the field and needs evolve. Other broad areas covered were the need for continuing education through tutorials at national conferences, and for journals to establish standards for reporting dosimetry. This workshop did not address issues of dosimetry for studies involving radiation focused at the sub-cellular level, internally-administered radionuclides, biodosimetry based on biological markers of radiation exposure, or dose reconstruction for epidemiological studies.
There is a great deal of interest in the establishment of a standardized animal model for the acute radiation syndrome to allow development of diagnostic approaches and countermeasure treatments following radiological terrorist events. Due to physiological, anatomical, and biochemical similarities to humans, the minipig is an attractive large animal model for evaluating countermeasure efficacy. This study was conducted in order to aid in the establishment of the minipig, and the Gottingen minipig in particular, as an animal model for the hematopoietic acute radiation syndrome. Animals were exposed whole-body to Co-60 at doses of 0 (sham control), 0.25, 0.5, 0.75, 1.0, and 2.0 Gy, and hematological parameters followed in time from pre-irradiation to post-irradiation Day 7. Following irradiation, a dose-dependent decrease in total white blood cells was observed, which was determined to be statistically different as compared to control animals at all dose levels above 0.25 Gy at 24 h post-irradiation. Similarly, a dose-dependent reduction in both absolute lymphocyte count and absolute neutrophil count occurred by the earliest time point measured for all exposed animals. A significant decrease in platelets was observed at postirradiation Day 7 in animals exposed only at the highest (2.0 Gy) level. The platelet-to-lymphocyte ratio generated for exposures ranging from 0.25-2.0 Gy was able to differentiate response between high and low exposure levels even at 7 d post exposure. In conclusion, the present study supports the development of the Gottingen minipig as a suitable large animal model to study radiation-induced hematopoietic syndrome.
Characterization measurements and calculations were performed on a new medical seed developed by IsoRay Inc. in Richland, Washington, that utilizes the short-lived isotope 131Cs. This model has recently received FDA 510(k) clearance. The objective of this work was to characterize the dosimetric properties of the new seed according to the AAPM Task Group 43 recommendations. Cesium-131 is a low-energy x-ray emitter, with the most prominent peaks in the 29 keV to 34 keV region. The intended application is brachytherapy for treating cancers in prostate, breast, head and neck, lung, and pancreas. The evaluations performed included air-kerma strength, radial dose function, anisotropy in phantom, half-life, energy spectra, and internal activity. The results indicate the CS-1 seeds have a dose-rate constant of 0.915 cGy hr(-1) U(-1) in water, dose penetration characteristics similar to 125I and 103Pd, anisotropy function values on the order of 0.71 at short distances and small angles, and an average anisotropy factor of 0.964. The overall dosimetric characteristics are similar to 125I and 103Pd seeds with the exception of half-life, which is 9.7 days, as compared to 17 days for 103Pd and 60 days for 125I. The shorter half-life may offer significant advantages in biological effectiveness.
Results of characterization studies on one of the first versions of the Sunna photo-fluorescent dosimeter™ have previously been reported, and the performance of the red fluorescence component described. This present paper describes dose response and post-irradiation characteristics of the green fluorescence component from the same dosimeter film (Sunna Model γ), which is manufactured using the injection molding technique. This production method may supply batch sizes on the order of 1 million dosimeter film elements while maintaining a signal precision (1σ) on the order of ±1% without the need to correct for variability of film thickness. The dosimeter is a 1cm×3cm polymeric film of 0.5-mm thickness that emits green fluorescence at intensities increasing almost linearly with dose. The data presented include dose response, post-irradiation growth, heat treatment, dosimeter aging, dose rate dependence, energy dependence, dose fractionation, variation of response within a batch, and the stability of the fluorimeter response. The results indicate that, as a routine dosimeter, the green signal provides a broad range of response at food irradiation (0.3–5kGy), medical sterilization (5–40kGy), and polymer cross-linking (40–250kGy) dose levels.
Evaluations on the influence of environmental variabilities on the red fluorescence component of the Sunna Model γ photo-fluorescent dosimeterTM have previously been reported. This present paper describes the environmental effects on the response of the green fluorescence component of the same dosimeter, which is manufactured using the injection molding technique. The results presented include temperature, relative humidity, and light influences both during and after irradiation. The green fluorescence signal shows a significant dependence on irradiation temperature below room temperature at 1%/°C. Above room temperature (approximately 24–60°C), the irradiation temperature effect varies from −0.1%/°C to 1.0%/°C, depending on the absorbed dose level. For facilities with irradiation temperatures between 30°C and 60°C and absorbed dose levels above 10kGy, irradiation temperature effects are minimal. Light-effects results indicate that the dosimeter is influenced by ultraviolet and blue wavelengths during irradiation as well as during the post-irradiation stabilization period (approximately 22h), requiring the use of light-tight packaging. Results also show that the dosimeter exhibits negligible effects from ambient moisture during and after irradiation when in the range of 33–95% relative humidity.
Characterization studies on one of the first versions of the Sunna fluorescent dosimeter™ have been published by Kovács and McLaughlin. This present study describes testing results of a newer version of the dosimeter (Model γ, batch 0399-20). This dosimeter is a 1-cm×3-cm polymeric film of 0.5mm thickness that emits a green fluorescence component at intensities almost linear with dose. The manufacturing method (injection molding) allows potential batch sizes on the order of a million while maintaining a signal precision on the order of ±1%. Studies include dose response, dose rate dependence, energy dependence, post-irradiation stability, environmental effects, and variation of response within a batch. Data for both food irradiation and sterilization dose levels were obtained. The results indicate that the green signal (0.3–250kGy) works well for food irradiation dose levels, especially in refrigerated facilities that maintain tight temperature control. The green signal also works well in sterilization facilities because its irradiation temperature coefficient above room temperature is minimal at sterilization doses. If the user requires readout results in < 22h after room temperature irradiation, the user can either calibrate for a specific post-irradiation readout time(s) or simply heat the dosimeters in a small laboratory oven to quickly stabilize the signal.
Growth in the use of ionising radiation for medical sterilisation and the potential for wide-scale international food irradiation have created the need for robust, mass-producible, inexpensive, and highly accurate radiation dosemeters. The Sunna dosemeter, lithium fluoride injection-moulded in a polyethylene matrix, can be read out using either green photoluminescence or ultraviolet (UV) absorption. The Sunna dosemeter can be mass-produced inexpensively with high precision. Both the photoluminescent and the UV absorption reader are simple and inexpensive. Both methods of analysis display negligible humidity effects, minimal dose rate dependence, acceptable post-irradiation effects, and permit measurements with a precision of nearly 1% 1sigma. The UV method shows negligible irradiation temperature effects from -30 degrees C to +60 degrees C. The photoluminescence method shows negligible irradiation temperature effects above room temperature for sterilisation dose levels and above. The dosimetry characteristics of these two readout methods are presented along with performance data in commercial sterilisation facilities.
The quick development concerning the commercial application of food irradiation in the USA recently resulted in growing marketing of irradiated red meat as well as irradiated fresh and dried fruits. These gamma and electron irradiation technologies require specific dosimetry systems for process control. The new version of the Sunna dosimeter has been characterized in gamma, electron and bremsstrahlung radiation fields by measuring the optically stimulated luminescence (osl) at 530 nm both below and above 1 kGy, i.e. for disinfestation and for meat irradiation purposes. No humidity and no significant dose rate effect on the green osl signal was observed. The temperature coefficient was determined from 0°C up to about 40°C and to stabilize the osl signal after irradiation a heat treatment method was introduced. Based on these investigations the Sunna ‘gamma’ film is a suitable candidate for dose control below and above 1 kGy for food irradiation technologies.
A new radiation dosimeter, consisting of an optically-stimulated polymer film containing a photofluorescent sensor, can serve as a routine dosimeter and radiographic imaging medium for high-dose applications in the absorbed dose range 0.1-100 kGy. The flexible, colorless, opalescent film having a uniform thickness of 0.240 (+/- 0.005) mm or certain other films in the thickness range 0.08-0.60 mm, are available in large batches. They can be read rapidly with a simple table-top spectrofluorimeter, excitation wavelength (lambda = 450 nm) and emission wavelength (lambda = 670 nm), giving a type A uncertainty of dose evaluation of < +/- 5% at 95% confidence level. It supplies either,single integrated dose readings or two-dimensional radiographic images with relatively high spatial resolution. The present work focuses on the following gamma-ray response characteristics of the system: inter- and intra-batch reproducibility, pre- and post-irradiation stability, and dependence of dose interpretations on absorbed dose rate and irradiation temperature. (C) 1999 Elsevier Science Ltd, All rights reserved.