A fiber optic biosensor to monitor mutans streptococci activity in human saliva is discussed. The developed biosensor is based on the selective bacterial growth medium and evanescent wave spectroscopy at the core-cladding interface of a multimode fiber to monitor the bacterial mediated biochemical reaction. In order to achieve this, a short length of the cladding is removed; the fiber core surface is treated and coated with a thin film of porous glass medium using sol-gel technique. During experiments, the mutans streptococci mediated reaction with sucrose is monitored using a photosensitive indicator, which is immobilized within the porous glass coating. This investigation highlights the potential benefits of the FOBS to monitor mutans streptococci activity in saliva.© (2003) COPYRIGHT SPIE--The International Society for Optical Engineering. Downloading of the abstract is permitted for personal use only.
A novel method and instrumental system to determine the total protein concentration in a liquid sample is described. It uses a fiber optic total protein sensor (FOPS) based on the principles of fiber optic evanescent wave spectroscopy. The FOPS applies a dye-immobilized porous glass coating on a multi-mode optical fiber. The evanescent waves at the fiber optic core-cladding interface are used to monitor the protein-induced changes in the sensor element. The FOPS offers a single-step method for quantifying protein concentrations without destroying the sample. The response time and reusability of the FOPS are evaluated. This unique sensing method presents a sensitive and accurate platform for the quantification of protein.
A fiber optic biosensor (FOBS) to monitor mutans streptococci activity in human saliva is developed. The biosensor utilizes e fiber optic evanescent wave spectroscopy to monitor a bacterial mediated biochemical reaction. To achieve this, a short length of the cladding is removed; the fiber core surface is treated and coated with a thin film of porous glass medium using sol–gel technique. The mutans streptococci mediated reaction with sucrose is monitored using a photosensitive indicator, which is immobilized within the porous glass coating. Spectroscopic analysis shows that the transmitted intensity at 597 nm increases conspicuously when monitored for 120 min. Two distinct phases are observed, one from 0 to 60 min and the other from 60 to 120 min. A negative correlation coefficient between the rate of increase in absorption peak intensity recorded by the FOBS and the decrease in pH measured using the pH meter, was calculated to be ρ=−0.994. This investigation highlights the potential benefits of this sensor to monitor mutans streptococci activity in saliva.
In this work a new approach based on the fiber Optic Evanescent Wave (FOEW) spectroscopy is developed for the effective determination of dental caries activity in human saliva. The biosensor design utilized the exponentially decaying wave that extends to the lower index region of the optical fiber's core-cladding interface. In order to achieve this, a short length of the cladding is removed and the fiber core surface is coated with a porous glass medium using solgel technique. The acidogenic profile resulting from the Streptococcus mutans activity in the human saliva is monitored using an indicator, which was encapsulated within the porous coating. These investigations display the potential benefits of FOEW based microbial sensor to monitor caries activity in human saliva.
In this work a new approach based on the fiber Optic Evanescent Wave (FOEW) Spectroscopy is developed for the effective determination of dental caries activity in human saliva. The biosensor design utilized the exponentially decaying wave that extends to the lower index region of the optical fiber's core-cladding interface. In order to achieve this, a short length of the cladding is removed and the fiber core surface is coated with a porous glass medium using sol-gel technique. The acidogenic profile resulting from the Streptococcus mutans activity in the human saliva is monitored using an indicator, which was encapsulated within the porous coating. These investigations display the potential benefits of FOEW based microbial sensor to monitor caries activity in human saliva.