The DAMIC-M (DArk Matter In CCDs at Modane) experiment employs thick, fully depleted silicon charged-coupled devices (CCDs) to search for dark matter particles with a target exposure of 1 kg-year. A novel skipper readout implemented in the CCDs provides single electron resolution through multiple non-destructive measurements of the individual pixel charge, pushing the detection threshold to the eV-scale. DAMIC-M will advance by several orders of magnitude the exploration of the dark matter particle hypothesis, in particular of candidates pertaining to the so-called "hidden sector." A prototype, the Low Background Chamber (LBC), with 20g of low background Skipper CCDs, has been recently installed at Laboratoire Souterrain de Modane and is currently taking data. We will report the status of the DAMIC-M experiment and first results obtained with LBC commissioning data.
Charge-coupled devices (CCDs) are a leading technology in direct dark matter searches because of their eV-scale energy threshold and high spatial resolution. The sensitivity of future CCD experiments could be enhanced by distinguishing nuclear recoil signals from electronic recoil backgrounds in the CCD silicon target. We present a technique for event-by-event identification of nuclear recoils based on the spatial correlation between the primary ionization event and the lattice defect left behind by the recoiling atom, later identified as a localized excess of leakage current under thermal stimulation. By irradiating a CCD with an $^{241}$Am$^{9}$Be neutron source, we demonstrate $>93\%$ identification efficiency for nuclear recoils with energies $>150$ keV, where the ionization events were confirmed to be nuclear recoils from topology. The technique remains fully efficient down to 90 keV, decreasing to 50$\%$ at 8 keV, and reaching ($6\pm2$)$\%$ at 1.5--3.5 keV. Irradiation with a $^{24}$Na $\gamma$-ray source shows no evidence of defect generation by electronic recoils, with the fraction of electronic recoils with energies $<85$ keV that are spatially correlated with defects $<0.1$$\%$.
The DArk Matter In CCDs at Modane (DAMIC-M) experiment is designed to search for light dark matter ( m(X) < 10 GeV/c(2)) at the Laboratoire Souter rain de Modane (LSM) in France. DAMIC-M will use skipper charge-coupled devices (CCDs) as a kg-scale active detector target. Its single-electron resolution will enable eV-scale energy thresholds and thus world-leading sensitivity to a range of hidden sector dark matter candidates. A DAMIC-M prototype, the Low Background Chamber (LBC), has been taking data at LSM since 2022. The LBC provides a low-background environment, which has been used to characterize skipper CCDs, study dark current, and measure radiopurity of materials planned for DAMIC-M. It also allows testing of various subsystems like readout electronics, data acquisition software, and slow control. This paper describes the technical design and performance of the LBC.
Dark Matter (DM) particles with sufficiently large cross sections may scatter as they travel through Earth's bulk. The corresponding changes in the DM flux give rise to a characteristic daily modulation signal in detectors sensitive to DM-electron interactions. Here, we report results obtained from the first underground operation of the DAMIC-M prototype detector searching for such a signal from DM with MeV-scale mass. A model-independent analysis finds no modulation in the rate of 1$e^-$ events with periods in the range 1-48 h. We then use these data to place exclusion limits on DM in the mass range [0.53, 2.7] MeV/c$^2$ interacting with electrons via a dark photon mediator. Taking advantage of the time-dependent signal we improve by $\sim$2 orders of magnitude on our previous limit obtained from the total rate of 1$e^-$ events, using the same data set. This daily modulation search represents the current strongest limit on DM-electron scattering via ultralight mediators for DM masses around 1 MeV/c$^2$.
We present results from a 3.25 kg-day target exposure of two silicon charge-coupled devices (CCDs), each with 24 megapixels and skipper readout, deployed in the DAMIC setup at SNOLAB. With a reduction in pixel readout noise of a factor of 10 relative to the previous detector, we investigate the excess population of low-energy events in the CCD bulk previously observed above expected backgrounds. We address the dominant systematic uncertainty of the previous analysis through a depth fiducialization designed to reject surface backgrounds on the CCDs. The measured bulk ionization spectrum confirms the presence of an excess population of low-energy events in the CCD target with characteristic rate of ${\sim}7$ events per kg-day and electron-equivalent energies of ${\sim}80~$eV, whose origin remains unknown.
Two dark matter searches performed with charge-coupled devices (CCDs) in the DAMIC cryostat at SNOLAB reported with high statistical significance the presence of an unidentified source of low-energy events in bulk silicon. The observed spectrum is consistent with nuclear recoils from the elastic scattering of weakly interacting massive particles (WIMPs) with masses between 2 and 3 GeV. In the standard scenario of spin-independent WIMP-nucleus scattering, the derived cross section is conclusively excluded by results in argon by the DarkSide-50 experiment. We identify isospin-violating and spin-dependent scenarios where interactions with ^40Ar are strongly suppressed and the interpretation of the DAMIC excess as WIMP-nucleus elastic scattering remains viable.
We report constraints on sub-GeV dark matter particles interacting with electrons from the first underground operation of DAMIC-M detectors. The search is performed with an integrated exposure of 85.23 g days, and exploits the subelectron charge resolution and low level of dark current of DAMIC-M charge-coupled devices (CCDs). Dark-matter-induced ionization signals above the detector dark current are searched for in CCD pixels with charge up to 7e^{-}. With this dataset we place limits on dark matter particles of mass between 0.53 and 1000 MeV/c^{2}, excluding unexplored regions of parameter space in the mass ranges [1.6,1000] MeV/c^{2} and [1.5,15.1] MeV/c^{2} for ultralight and heavy mediator interactions, respectively.
Experiments aiming to directly detect dark matter through particle recoils can achieve energy thresholds of Oo10 eV thorn . In this regime, ionization signals from small-angle Compton scatters of environmental gamma rays constitute a significant background. Monte Carlo simulations used to build background models have not been experimentally validated at these low energies. We report a precision measurement of Compton scattering on silicon atomic shell electrons down to 23 eV. A skipper charge-coupled device with single -electron resolution, developed for the DAMIC-M experiment, was exposed to a 241Am gamma-ray source over several months. Features associated with the silicon K-, L1-, and L2;3-shells are clearly identified, and scattering on valence electrons is detected for the first time below 100 eV. We find that the relativistic impulse approximation for Compton scattering, which is implemented in Monte Carlo simulations commonly used by direct detection experiments, does not reproduce the measured spectrum below 0.5 keV. The data are in better agreement with ab initio calculations originally developed for x-ray absorption spectroscopy.
We construct the first comprehensive radioactive background model for a dark matter search with charge-coupled devices (CCDs). We leverage the well-characterized depth and energy resolution of the DAMIC at SNOLAB detector and a detailed GEANT4-based particle-transport simulation to model both bulk and surface backgrounds from natural radioactivity down to 50 eV(ee). We fit to the energy and depth distributions of the observed ionization events to differentiate and constrain possible background sources, for example, bulk 3 H from silicon cosmogenic activation and surface Pb-210 from radon plate-out. We observe the bulk background rate of the DAMIC at SNOLAB CCDs to be as low as 3.1 +/- 0.6 counts kg(-1) day(-1) keV(ee)(-1), making it the most sensitive silicon dark matter detector. Finally, we discuss the properties of a statistically significant excess of events over the background model with energies below 200 eV(ee).
Experimental efforts of the last decades have been unsuccessful in detecting WIMPs (Weakly Interacting Massive Particles) in the 10-to-10(4) GeV/c(2) range, thus motivating the search for lighter dark matter. The DAMIC (DArk Matter In CCDs) at SNOLAB experiment aims for direct detection of light dark matter particles (m(chi) < 10 GeV/c(2)) by means of CCDs (Charge-Coupled Devices). Fully-depleted 675 mu m-thick CCDs are used to such end. The optimized readout noise and operation at cryogenic temperatures allow for a detection threshold of 50 eV(ee) electron-equivalent energy. Focusing on nuclear and electronic scattering as potential detection processes, DAMIC has so far set competitive constraints on the detection of low mass WIMPs and hidden-sector particles. In this work, an 11 kg center dot d exposure dataset is exploited to search for light WIMPs by building the first comprehensive radioactive background model for CCDs. Different background sources are discriminated making conjoint use of the spatial distribution and energy of ionization events, thereby constraining the amount of contaminants such as tritium from silicon cosmogenic activation and surface lead-210 from radon plate-out. Despite a conspicuous, statistically-significant excess of events below 200 eV(ee), this analysis places the strongest exclusion limit on the WIMP-nucleon scattering cross section with a silicon target for m(chi) < 9 GeV/c(2).
Many low-threshold experiments observe sharply rising event rates of yet unknown origins below a few hundred eV, and larger than expected from known backgrounds. Due to the significant impact of this excess on the dark matter or neutrino sensitivity of these experiments, a collective effort has been started to share the knowledge about the individual observations. For this, the EXCESS Workshop was initiated. In its first iteration in June 2021, ten rare event search collaborations contributed to this initiative via talks and discussions. The contributing collaborations were CONNIE, CRESST, DAMIC, EDELWEISS, MINER, NEWS-G, NUCLEUS, RICOCHET, SENSEI and SuperCDMS. They presented data about their observed energy spectra and known backgrounds together with details about the respective measurements. In this paper, we summarize the presented information and give a comprehensive overview of the similarities and differences between the distinct measurements. The provided data is furthermore publicly available on the workshop's data repository together with a plotting tool for visualization.
We present measurements of bulk radiocontaminants in the high-resistivity silicon CCDs from the DAMIC experiment at SNOLAB. We utilize the exquisite spatial resolution of CCDs to discriminate between α and β decays, and to search with high efficiency for the spatially-correlated decays of various radioisotope sequences. Using spatially-correlated β decays, we measure a bulk radioactive contamination of 32Si in the CCDs of 140 ± 30 μBq/kg, and place an upper limit on bulk 210Pb of < 160 μBq/kg. Using similar analyses of spatially-correlated α and β decays, we set upper limits of < 11 μBq/kg (0.9 ppt) on 238U and < 7.3 μBq/kg (1.8 ppt) on 232Th in the bulk silicon. The ability of DAMIC CCDs to identify and reject spatially-coincident backgrounds, particularly from 32Si, has significant implications for the next generation of silicon-based dark matter experiments, where β's from 32Si decay will likely be a dominant background.
We present constraints on the existence of weakly interacting massive particles (WIMPs) from an 11 kg d target exposure of the DAMIC experiment at the SNOLAB underground laboratory. The observed energy spectrum and spatial distribution of ionization events with electron-equivalent energies >200 eV_{ee} in the DAMIC CCDs are consistent with backgrounds from natural radioactivity. An excess of ionization events is observed above the analysis threshold of 50 eV_{ee}. While the origin of this low-energy excess requires further investigation, our data exclude spin-independent WIMP-nucleon scattering cross sections σ_{χ-n} as low as 3×10^{-41} cm^{2} for WIMPs with masses m_{χ} from 7 to 10 GeV c^{-2}. These results are the strongest constraints from a silicon target on the existence of WIMPs with m_{χ}<9 GeV c^{-2} and are directly relevant to any dark matter interpretation of the excess of nuclear-recoil events observed by the CDMS silicon experiment in 2013.