A HARPICON(TM) camera has been applied to a digital angiography system with fluorescent-screen optical-lens coupling. It uses avalanche multiplication in the photoconductive layer for high-sensitivity imaging. The limiting spatial resolutions in the 1050 scanning-line mode of the camera are about 30 and 50 micro m at input field sizes of 20 x 20 and 50 x 50 mm on the screen, respectively. For high-speed imaging, the 525 scanning-line mode at a rate of 60 images s(-1) can be selected. High-quality images of coronary arteries in dogs were obtained by intra-aortic coronary angiography and superselective coronary angiography using a single-energy X-ray above the iodine K-edge energy.
PURPOSE:To evaluate the usefulness of a radiographic system with monochromatic synchrotron radiation to depict small vessels and peripheral secretory ducts.MATERIALS AND METHODS:Radiography of various organs was tested in 14 anesthetized dogs and pancreatography was performed in an excised human pancreas by using the following system: monochromatic synchrotron radiation with an energy level just above the k absorption edge of iodine as an x-ray source and a high-definition TV system with a high-light-sensitivity image pick-up tube camera coupled with a fluorescent screen as a detector.RESULTS:This system allowed depiction of small vessels (diameter < 50-100 microns) of the heart (penetrating transmural artery), brain (perforating arteries that arise directly in the circle of Willis), and intestinal organs (vasa recta and their submucosal communications) and of small branches (down to the fifth order) of the pancreatic duct.CONCLUSION:The synchrotron radiation system may be useful for evaluating microcirculatory disorders and early-stage malignant tumors in various human organs.
We have developed a monochromatic synchrotron radiation-excited system for two-dimensional mapping of x-ray fluorescence evoked from heavy element-loaded microspheres, which can evaluate myocardial blood flow in small contiguous regions with a small methodological error: 10.8 +/- 2.4% of the average of difference of the dual flow for 7- to 10-mg myocardial tissue (4 dogs). The fractal D value obtained from the slope of the log relative dispersion-log mass plot was 1.21 +/- 0.08 for a voxel size of 7 to 1260 mg (5 dogs) and that for a voxel size of 2.5 to 40 mg (1.12 +/- 0.06) was smaller than that for a voxel size of 40 to 1280 mg (1.25 +/- 0.14, P < .05, ANOVA, 4 dogs). The distance-correlation coefficient relation for paired myocardial regions was attenuated (correlation analysis), and the correlation coefficients between the original grouping and the two aggregates of the adjacent regions were dissociated (extended correlation analysis) under reduction of coronary perfusion pressure (6 dogs). Suppression of myocardial contraction with lidocaine (3 dogs) and vasodilation with adenosine partly improved the distance-correlation coefficient relation under reduced coronary perfusion pressure. Thus, an x-ray fluorescence system designed for precise flow measurement shows that the fractal nature of local flow distribution can be extended into regions smaller than previously reported, that in these regions the flow becomes more homogeneous, and that the self similarity and continuity of local flow are attenuated by the reduction of coronary perfusion pressure and improved by contractile suppression and coronary vasodilation.