ICP-MS is a sensitive element analysis technique used for analyzing several different sample types.
Neuropathic pain affects 1-10% of the general population and is caused by a lesion or disease of the somatosensory nervous system. Spinal cord stimulation (SCS), a method where implanted electrodes stimulate the spinal cord, has been successfully used to treat drug-resistant neuropathic pain, but the mechanism of action is largely unknown. Studies show that SCS changes the protein levels in CSF (cerebrospinal fluid) of pain patients. Several neurological conditions have been shown to alter the elemental composition of CSF. Therefore changes in the levels of ions and trace elements in the CSF may correspond to SCS use. This study used ICP-MS (Inductively coupled plasma mass spectrometry) and ICP-AES (Inductively coupled plasma atomic emission spectroscopy) to quantify 10 elements in CSF from chronic neuropathic pain patients using SCS. The element concentrations in CSF from patients with SCS treatment on/off, were measured. No effect on the element concentrations in CSF from treatment with SCS could be detected. Also, the elemental concentrations in pooled CSF from patients without chronic neuropathic pain was determined and compared to the patients using SCS. The concentration of the elements Ca, Sr, Na, K, P, Mg and Ti were, significantly higher in patients compared to the CSF-control.
The aim of this study was to investigate the protein content in aqueous humor in eyes with and without pseudoexfoliations (PEX) and to evaluate the quantitative proteomics method, isobaric tagging for relative and absolute protein quantification (iTRAQ), in combination with two separation methods followed by matrix-assisted Laser desorption/ionization (MALDI) mass spectrometry and tandem mass spectrometry (MS/MS). During cataract surgery, samples of aqueous humor were collected from 20 eyes with PEX and from 18 control eyes. The relative concentrations of proteins in the pooled samples of ten PEX eyes and eight controls were evaluated after trypsin digestion and Labeling of the peptides with (iTRAQ) reagent. Two separation methods, Liquid chromatography (LC) and capillary electrophoresis (CE) were used, followed by MALDI mass spectrometry and MS/MS. Furthermore, 1D gel electrophoresis was performed on the remaining ten pooled PEX samples and ten control samples. The gel material was separated by nano-liquid chromatography (nano-LC) followed by Linear-ion-trap quadrupole Fourier transformation ion cyclotron resonance (FT-ICR). Fifty four proteins were identified in the LC runs and 24 with CE. The relative concentrations of beta-crystallines B2 and S were raised and those of angiotensinogen and osteopontin Lowered in the PEX sample compared to the control. The trends regarding beta-crystallines B2, angiotensinogen and osteopontin were confirmed by the 1D gel electrophoresis.
A fast mix and measure method for direct multi element analysis of non digested biological samples was used for the simultaneous determination of low, medium, and high concentrations elements in li ...
A fast method for direct multi-element analysis of non-digested biological samples is presented. The only sample preparation needed is 1 min homogenization with a Polytron mixer in a small volume of neutral phosphate buffer saline solution (PBS). The total time for analysis (sample preparation and measurement) is 4 min only. This “mix and measure” method can handle large sample loads of biological samples and thus minimize dilution of trace elements. For example 100% whole blood was introduced without any clogging of the introduction system or extinguishing of the plasma. In 70% (v/v) whole blood reference material 14 of 16 analytes were quantified within ±10% (Al, B, Ba, Ca, Cu, Fe, Mg, Mn, P, Pb, S, Sr, Ti and Zn) and two semi-quantified within ±20% (Cd and K). Fresh bovine liver was also analyzed with the same method and 7 of 9 analytes were quantified in 5% (w/v) liver slurry. Three different nebulizers were tested, Glass Expansion Concentric (GEC) of Meinhard type, Cross Flow and Burgener T2100 and they performed roughly equally well in giving quantitative results for the slurries but the sensitivity was better with the GEC. The stability of the plasma was studied by evaluating the ratio of Mg 280.270 nm and Mg 285.213 nm lines. When increasing the sample load from 20 to 100% (v/v) of whole blood and from 0.5 to 10% (w/v) of bovine liver the Mg ratio was constant within a few percent for all of the nebulizer tested. The ratio of the sensitivity between GEC and Burgener T2100 was studied and the ratio increased with the energy sum for atomic and ionic lines separately.
Analysis of proteins in human body fluids is challenging since the composition of the sample often is rather complex. Here we present a method for analysis of proteins in aqueous humor from two groups of cataract patients, with and without pseudoexfoliation (PEX). Aqueous humor is an extracellular fluid contained in the anterior chamber of the eye between the cornea and iris. The limited volume of sample requires sophisticated analysis techniques. Our method is based on a total tryptic digestion of the sample followed by capillary LC-MALDI MS and MS/MS analysis of the peptides. The method is rapid, efficient and suitable as a complement or alternative to more commonly used methods based on gel electrophoretic experiments. With this method we found and unambiguously identified 30 nonredundant proteins. Proteins found include general transport proteins such as albumin and apolipoprotein A1 but also specific proteins involved in immune response, such as complement factors. Cystatin C, clusterin, and crystallins were also found. Although the number of proteins was roughly the same in both groups there was a significant difference in their identities. These findings may give some new insights into the pathophysiology of the PEX syndrome.
In analytical chemistry the main goal is normally to determine the identity and/or concentration of one or more species in a sample. The samples analyzed are often natural samples, containing numerous different species in a complex matrix and the choice of technique for multi-elemental detection is in general inductively coupled plasma spectrometry. The chemical forms of an element can affect many of its characteristics e.g. toxicity, which makes speciation analysis important. Therefore, determination of the identity and quantity of an element is still important, but for many applications measurements of total element concentration provides insufficient information. To be able to perform speciation analysis, separation, identification and/or characterization of the various forms of elements in the sample has to be accomplished. Speciation analysis has been employed in a wide range of disciplines, including for example environmental science, biology and clinical chemistry. This thesis describes work to improve and understand the elemental speciation analysis with liquid chromatography coupled to plasma spectrometry and also highlights the importance and potential of the synergy between atomic spectrometry and molecular mass spectrometry. The combination of the matrix tolerant, robust and very sensitive plasma spectrometry used together with molecular mass spectrometry, which provides structural information and the possibility to identify unknown species, is demonstrated to be a very powerful tool for speciation analysis. In this thesis methods are developed for on-line sample clean-up and pre-concentration coupled to liquid chromatography and plasma spectrometry, which makes handling of small sample volumes easier and also decreases the risk of contamination. The problems associated with organic modifiers in plasma spectrometry are also addressed. Applications of speciation analysis are exemplified by analysis of aluminium-chelated siderophores in field-soil solutions and organic phosphorous species in aquatic sediments. The possibility to analyze un-dissolved samples as slurries with minimal sample preparation is also discussed.
Column-switching liquid chromatography followed by low resolution ICP-MS was evaluated as a tool for speciation analysis of aluminium-containing biomolecules. The strategy was applied on siderophores, small organic molecules (Mr < 1500) which normally act as strong iron chelators. The drawbacks normally encounterd with aluminium detection using low resolution ICP-MS are the formation of polyatomic ions causing isobaric overlaps and space-charge effects. When adding a carbon rich solvent, such as methanol or acetonitrile, the 13C14N+, 12C15N+ and 12C14N1H+ with the same mass as 27Al+ will form in the plasma. The nitrogen is either entrained from the surrounding atmosphere or added with the constituents in the mobile phase. These disadvantages were successfully counteracted by the use of nitrogen free organic modifier in the mobile phase and the use of cool plasma conditions. Detection limits for standard solutions of aluminium-chelated ferrichrome in sub-nanomolar range were obtained by monitoring the aluminium-27 isotope. The combined use of LC-ICP-MS and LC-ESI-MS/MS was also evaluated as a tool to identify unknown metal complexes, here siderophores, in field soil solution samples. Two aluminium-chelated siderophores, Al-desferrichrom and Al-desferricrocin, were identified and quantified. Both aluminium-siderophore complexes were present in the low nanomolar range (1.1 and 0.7 nM, respectively).
Information on protein expression, disease biomarkers or surrogate markers and genetic disorders can nowadays be achieved from analysis of complex biological samples by liquid separation coupled to mass spectrometric (MS) detection. This paper describes fast multidimensional separation by on-line liquid chromatography (LC) and capillary electrophoresis (CE), followed by electrospray ionization (ESI) Fourier transform ion cyclotron resonance (FTICR) MS detection. This detector provides ultrahigh resolution of the detected ions, mass accuracy at the ppm-level and high sensitivity. Most of the challenge of this system lies in the development of a new interface for the on-line coupling of LC to CE. The interface developed in poly(dimethylsiloxane) provides a RSD for injection repeatability of <3.5% and surface control for unspecific binding by deactivation with a cationic polymer, PolyE-323. We have evaluated the interface, as well as the overall system, with respect to robustness and deconvolution ability. Sequence coverage for bovine serum albumin (BSA) of 93% showed a high recovery of sample in the different transfer steps through the system. The detection limit for identification is 277 ng mL(-1) (or 280 nM) on average for peptides. In the future, we expect LC-CE-MS to be a novel strategy for elucidating the chemistry of biological matrices.
The aim of this study was to examine changes in the systemic immune response during the incubation period and following the onset of clinical swine dysentery, including the recovery period. Ten healthy conventional pigs were inoculated with Brachyspira hyodysenteriae. Blood was sampled at pre-inoculation, at days 4 and 14 post-inoculation, during the first 4 days with clinical signs of dysentery and at days 1, 3, 7, 11 and 15 of the recovery period. Eight pigs developed haemorrhagic diarrhoea. Flow-cytometric analyses of lymphocyte subpopulations showed that all animals, including the two that remained healthy, had an increase in CD8alpha+ CD4- cells and gammadelta T cells at days 4 and 14 post-inoculation. In addition, an increase in CD4+ CD8alpha+ cells and CD8alpha+ CD8beta+ cells was observed at days 4 and 14 post-inoculation in animals that developed dysentery. During clinical signs of dysentery, the acute-phase protein serum amyloid A was increased. There was a two- to threefold increase in both neutrophils and monocytes during signs of dysentery and at the beginning of the recovery period. The numbers of CD8alpha+ CD8beta- CD4-, CD45RA- lymphocytes also increased during the dysentery period. Circulating CD21+ cells and CD21+ CD45RA- cells decreased at the end of the incubation period, during signs of dysentery and at the beginning of the recovery period. The dysentery-affected animals developed antibodies to B. hyodysenteriae-specific antigens (approximately 16 kDa and approximately 30 kDa) from the first day of recovery, and gammadelta T cells showed an increase during the recovery period. In comparison with pre-inoculation, increased numbers of monocytes, neutrophils, CD8alpha+ CD8beta- CD4- lymphocytes and CD45RA- lymphocytes were observed during clinical dysentery. Increased numbers of neutrophils, gammadelta T cells and specific antibodies were seen during the recovery period.
Advances in life science require knowledge of active molecules in complex biological systems. These molecules are often only present for a certain time and at limited concentrations. Integrated micro-analytical tools for sampling, separation and mass spectrometric (MS) detection would meet these requests and are therefore continuously gaining interest. An on-line coupling of analytical functions provides shorter analysis time and less manual sample handling. In this thesis, improved compatibility of microdialysis sampling and multidimensional separations coupled to MS detection are developed and discussed. Microdialysis was used in vitro for determination of the non-protein bound fraction of the drug ropivacaine. The sampling unit was coupled on-line to capillary column liquid chromatography (LC) followed by ultraviolet or MS detection. For MS detection, the system was extended with a desalting step and an addition of internal standard. A method for MS screening of microdialysates, collected in vivo, was also developed. The method involved sampling and measurements of the chemical pattern of molecules that generally are ignored in clinical investigations. Chemometric tools were used to extract the relevant information and to compare samples from stimulated and control tissues. Complex samples often require separation in more than one dimension. On-line interfaces for sample transfer between LC and capillary electrophoresis (CE) were developed in soft poly(dimethylsiloxane) (PDMS). MS detection in the LC-CE system was optimised on frequent sampling of the CE peak or on high resolution in mass spectra using time-of-flight (TOF)MS or Fourier transform ion cyclotron resonance (FTICR)MS, respectively. Aspects on electrode positioning in the LC-CE interface led to development of an on-column CE electrode. A successful method for deactivation of the PDMS surface using a polyamine polymer was also developed. The systems were evaluated using peptides and proteins, molecules that are gaining increased attention in bioscience, and consequently also in chemical analysis.
This thesis exemplifies the strength in the combination of inductively coupled plasma (ICP) spectrometry and electrospray ionization tandem mass spectrometry ESI-MS/MS as detection techniques for liquid chromatography (LC) in the search for and investigation of compounds that bind or can bind hetero-atoms. Furthermore, some aspects involved in the coupling of LC and ICP spectrometry and quantification without identical standards have been studied.The importance of using a separation step in combination with ICP spectrometry was shown for urine and blood plasma samples from patients treated with boron neutron capture therapy. In addition to the carrier molecule used in the therapy, one major and a few possible minor metabolites were found in the urine samples. One fragment mass of the major metabolite was obtained with LC-ESI-MS/MS. Liquid chromatography coupled to ICP-MS was also shown to be a valuable tool for fingerprinting metal-binding compounds in complex matrices, such as siderophores (iron-complexing compounds) in soil. The presence of at least two siderophores in a field soil solution sample could be revealed by LC-ICP-MS. Their identities could thereafter be determined by LC-ESI-MS/MS.The non-UV-absorbing o-carboranylalanine could be quantified in relation to its degradation products by LC-ICP-AES, which provided information about the mechanism behind the degradation. Moreover, LC-ICP spectrometry was shown to provide an accurate quantification of biomolecules (bias < 10 %) when evaluated from external calibration graphs based on inorganic elemental standards.Finally, the causes of the large decrease in boron signal seen when adding acetonitrile to the LC mobile phase in LC-ICP-MS was investigated in some detail. Space charge effects might explain a large part of the depression from carbon species on the boron signal.
ADVERTISEMENT RETURN TO ISSUEPREVArticleNEXTDetermination and speciation of selenium in end products from a garbage incineratorChristina Ericzon, Jean Pettersson, Marit Andersson, and Aake OlinCite this: Environ. Sci. Technol. 1989, 23, 12, 1524–1528Publication Date (Print):December 1, 1989Publication History Published online1 May 2002Published inissue 1 December 1989https://pubs.acs.org/doi/10.1021/es00070a012https://doi.org/10.1021/es00070a012research-articleACS PublicationsRequest reuse permissionsArticle Views72Altmetric-Citations15LEARN ABOUT THESE METRICSArticle Views are the COUNTER-compliant sum of full text article downloads since November 2008 (both PDF and HTML) across all institutions and individuals. These metrics are regularly updated to reflect usage leading up to the last few days.Citations are the number of other articles citing this article, calculated by Crossref and updated daily. Find more information about Crossref citation counts.The Altmetric Attention Score is a quantitative measure of the attention that a research article has received online. Clicking on the donut icon will load a page at altmetric.com with additional details about the score and the social media presence for the given article. Find more information on the Altmetric Attention Score and how the score is calculated. Share Add toView InAdd Full Text with ReferenceAdd Description ExportRISCitationCitation and abstractCitation and referencesMore Options Share onFacebookTwitterWechatLinked InRedditEmail Other access optionsGet e-Alertsclose Get e-Alerts