Newborn screening (NBS) for Krabbe disease (KD) in New York and Missouri is conducted by measuring galactocerebrosidase (GALC) activity using tandem mass spectrometry (MS/MS). These NBS efforts have shown that the incidence of KD is unexpectedly low (1:400,000) while many individuals (ca. 1:6000) with reduced GALC activity and genotypes of uncertain significance are detected and subjected to follow up testing. Psychosine (PSY) is a putative marker of KD progression and can be measured in dried blood spots (DBS). We sought to determine the role that PSY levels play in NBS for KD, follow up, and treatment monitoring.
Background: Pre-symptomatic hematopoietic stem cell transplantation is essential to achieve best possible outcomes for patients with the childhood cerebral form of X-linked adrenoleukodystrophy (X-ALD). We describe a high-throughput method for measurement of C-20-C-26 lysophosphatidylcholines (LPCs) and biochemical diagnosis of X-ALD using the same dried blood spots (DBS) routinely used for newborn screening. Methods: LPCs are extracted from 3-mm DBS punch with methanol containing an isotopically labeled LPC as internal standard. This extract is transferred to a 96-well plate, evaporated and then reconstituted in mobile phase for flow injection analysis tandem mass spectrometry (FIA-MS/MS) in selected reaction monitoring mode for measurement of four different LPCs (C-20, C-22, C-24, C-26) and the internal standard (d(4)-C-26-LPC). Analysis time is 1.5 min per sample. Results: The mean CVs from the intra- and inter-assay experiments for LPCs were 6.3-15.1% for C20-LPC, 4.418.6% for C-22-LPC and 4.5-143% for C-24-LPC. Limits of detection were determined for C-20-LPC CLOD = 0.03 mu g/mL), C-22-LPC (0.03 mu g/mL), C-24-LPC (0.03 mu g/mL) and C-26-LPC (0.01 mu g/mL). Reference ranges were established from DBS of 130 newborns and 20 adults. Samples of patients with X-ALD (n = 16), peroxisomal biogenesis disorders (n = 8), and X-ALD carriers (n = 12) were analyzed blindly and all were correctly identified. Conclusion: Analysis of LPC species by FIA-MS/MS is a fast, simple and reliable method to screen for X-ALD and other peroxisomal disorders in DBS. To maximize specificity, abnormal results can be verified by a 2nd tier assay using LC-MS/MS. (C) 2014 Elsevier Inc. All rights reserved.
Purpose: To improve quality of newborn screening by tandem mass spectrometry with a novel approach made possible by the collaboration of 154 laboratories in 49 countries. Methods: A database of 767,464 results from 12,721 cases affected with 60 conditions was used to build multivariate pattern recognition software that generates tools integrating multiple clinically significant results into a single score. This score is determined by the overlap between normal and disease ranges, penetration within the disease range, differences between conditions, and weighted correction factors. Results: Ninety tools target either a single condition or the differential diagnosis between multiple conditions. Scores are expressed as the percentile rank among all cases with the same condition and are compared to interpretation guidelines. Retrospective evaluation of past cases suggests that these tools could have avoided at least half of 279 false-positive outcomes caused by carrier status for fatty-acid oxidation disorders and could have prevented 88% of known false-negative events. Conclusion: Application of this computational approach to raw data is independent from single analyte cutoff values. In Minnesota, the tools have been a major contributing factor to the sustained achievement of a false-positive rate below 0.1% and a positive predictive value above 60%. Genet Med advance online publication 16 February 2012
Glycosaminoglycans (GAGs) are negatively charged long linear (highly sulfated) polysaccharides consisting of repeating disaccharide units that are expressed on the surfaces of all nucleated cells. The expression of GAGs is required for embryogenesis, regulation of cell growth and proliferation, maintenance of tissue hydration, and interactions of the cells via receptors. Mucopolysaccharidoses (MPS) are caused by deficiency of specific lysosomal enzymes that result in the accumulation of GAGs in multiple tissues leading to organ dysfunction. Therefore, GAGs are important biomarkers for MPS. Without any treatment, patients with severe forms of MPS die within the first two decades of life.Accurate measurement of GAGs is important to understand the diagnosis and pathogenesis of MPS and to monitor therapeutic efficacy before, during, and after treatment of the disease. This review covers various qualitative and quantitative methods for measurement of GAGs, including dye specific, thin layer chromatography (TLC), capillary electrophoresis, high-performance liquid chromatography (HPLC), liquid chromatography-tandem mass spectrometry (LC-MS/MS), gas chromatography, ELISA, and automated high-throughput mass spectrometry. Major conclusion: There are several methods for GAG detection however, specific GAG detection in the various biological systems requires rapid, sensitive, specific, and cost-effective methods such as LC-MS/MS.This review will describe different methods for GAG detection and analysis, including their advantages and limitation.
BACKGROUND:Newborn screening (NBS) for inborn errors of propionate, methionine, and cobalamin metabolism relies on finding abnormal concentrations of methionine and propionylcarnitine. These analytes are not specific for these conditions and lead to frequent false-positive results. More specific markers are total homocysteine (tHCY), methylmalonic acid (MMA), and methylcitric acid (MCA), but these markers are not detected by current NBS methods. To improve this situation, we developed a method for the detection of tHCY, MMA, and MCA in dried blood spots (DBSs) by liquid chromatography-tandem mass spectrometry (LC-MS/MS).METHODS:The analytes were extracted from a single 4.8-mm DBS punch with acetonitrile:water:formic acid (59:41:0.42) containing dithiothreitol and isotopically labeled standards (d(3)-MMA, d(3)-MCA, d(8)-homocystine). The extract was dried and treated with 3 N HCl in n-butanol to form butylesters. After evaporation of the butanol, the residue was reconstituted and centrifuged and the supernatant was subjected to LC-MS/MS analysis. Algorithms were developed to apply this method as an efficient and effective second-tier assay on samples with abnormal results by primary screening.RESULTS:The 99th percentiles determined from the analysis of 200 control DBSs for MMA, MCA, and HCY were 1.5, 0.5, and 9.8 μmol/L, respectively. Since 2005, prospective application of this second-tier analysis to 2.3% of all NBS samples led to the identification of 13 affected infants.CONCLUSIONS:Application of this assay reduced the false-positive rate and improved the positive predictive value of NBS for conditions associated with abnormal propionylcarnitine and methionine concentrations.
We report the artifactual elevation of homogentisic acid (HGA) in urine from alkaptonuric patients after replacing the creatinine method (Jaffe reaction) in our laboratory with an automated enzymatic method. Samples with elevated HGA by GC-MS had lower creatinine values as determined by the enzymatic method than by the Jaffe reaction. The low creatinine values were due to interference by HGA in the enzymatic method. The enzymatic method is unsuitable for creatinine determination in urine of patients with alkaptonuria.
BACKGROUND Newborn screening for maple syrup urine disease (MSUD) relies on finding increased concentrations of the branched-chain amino acids (BCAAs) leucine, isoleucine, and valine by tandem mass spectrometry (MS/MS). d-Alloisoleucine (allo-Ile) is the only pathognomonic marker of MSUD, but it cannot be identified by existing screening methods because it is not differentiated from isobaric amino acids. Furthermore, newborns receiving total parenteral nutrition often have increased concentrations of BCAAs. To improve the specificity of newborn screening for MSUD and to reduce the number of diet-related false-positive results, we developed a LC-MS/MS method for quantifying allo-Ile. METHODS Allo-Ile and other BCAAs were extracted from a 3/16-inch dried blood spot punch with methanol/H2O, dried under nitrogen, and reconstituted into mobile phase. Quantitative LC-MS/MS analysis of allo-Ile, its isomers, and isotopically labeled internal standards was achieved within 15 min. To determine a reference interval for BCAAs including allo-Ile, we analyzed 541 dried blood spots. We also measured allo-Ile in blinded samples from 16 MSUD patients and 21 controls and compared results to an HPLC method. RESULTS Intra- and interassay imprecision (mean CVs) for allo-Ile, leucine, isoleucine, and valine ranged from 1.8% to 7.4%, and recovery ranged from 91% to 129%. All 16 MSUD patients were correctly identified. CONCLUSIONS The LC-MS/MS method can reliably measure allo-Ile in dried blood spots for the diagnosis of MSUD. Applied to newborn screening as a second-tier test, it will reduce false-positive results, which produce family anxiety and increase follow-up costs. The assay also appears suitable for use in monitoring treatment of MSUD patients.
BACKGROUND Tyrosinemia type I (TYR 1) is a disorder causing early death if left untreated. Newborn screening (NBS) for this condition is problematic because determination of the diagnostic marker, succinylacetone (SUAC), requires a separate first-tier or only partially effective second-tier analysis based on tyrosine concentration. To overcome these problems, we developed a new assay that simultaneously determines acylcarnitines (AC), amino acids (AA), and SUAC in dried blood spots (DBS) by flow injection tandem mass spectrometry (MS/MS). METHODS We extracted 3/16-inch DBS punches with 300 microL methanol containing AA and AC stable isotope-labeled internal standards. This extract was derivatized with butanol-HCl. In parallel, we extracted SUAC from the residual filter paper with 100 microL of a 15 mmol/L hydrazine solution containing the internal standard 13C5-SUAC. We combined the derivatized aliquots in acetonitrile for MS/MS analysis of AC and AA with additional SRM experiments for SUAC (m/z 155-137) and 13C5-SUAC (m/z 160-142). Analysis time was 1.2 min. RESULTS SUAC was increased in retrospectively analyzed NBS samples of 11 TYR 1 patients (length of storage, 52 months to 1 week; SUAC range, 13-81 micromol/L), with Tyr concentrations ranging from 65 to 293 micromol/L in the original NBS analysis. The mean concentration of SUAC in 13 521 control DBS was 1.25 micromol/L. CONCLUSION The inclusion of SUAC analysis into routine analysis of AC and AA allows for rapid and cost-effective screening for TYR 1 with no tangible risk of false-negative results.
BACKGROUND:Tyrosinemia type I (TYR 1) is a severe disorder causing early death if left untreated. While tyrosine can be determined in dried blood spots (DBS), it is not a specific marker for TYR 1 and most often associated with benign transient tyrosinemia of the newborn. Succinylacetone (SUAC) is a specific marker for TYR 1 but not detectable by routine newborn screening. We developed a new assay that determines SUAC in DBS by liquid-chromatography tandem mass spectrometry (LC-MS/MS). METHODS:Whole blood is eluted from a 3/16-in. DBS by an aqueous solution containing deuterium labeled SUAC as internal standard (IS). SUAC and IS are oximated, then extracted, butylated, and analyzed by LC-MS/MS. Quantitation is from SUAC spiked calibrator DBS over the range 0-200 microM using selected reaction monitoring of transitions m/z 212 to 156 and m/z 214 to 140 for SUAC and IS, respectively. Analysis time is 5 min. To assess the effectiveness of a two-tier screening approach for TYR 1 we applied this assay to our newborn screening program over the last 15 months. RESULTS:The intra-assay precision was determined for three different levels of SUAC (5, 20, and 50 micromol/L) and the CV calculated to be 4.7, 2.6, and 3.1%, respectively (n=5). Inter-assay precision CVs were 12.7, 8.2, and 7.8%, respectively on the same samples. SUAC levels in DBS from 10 confirmed TYR 1 cases not treated with 2-(2-nitro-4-trifluoromethylbenzoyl)-1,3-cyclohexanedione (NTBC) were clearly abnormal (16-150 micromol/L; mean: 61 micromol/L; controls: <5 micromol/L). Over a 15-month period, SUAC was determined in newborn screening samples with elevated tyrosine concentrations when applying different cut off values until it was settled at 150 micromol/L. No case of TYR 1 was detected in 124,780 newborns tested. CONCLUSION:We have developed a new LC-MS/MS based method for the determination of SUAC in DBS. This assay has the potential to significantly reduce the number of false positive results in newborn screening for TYR 1 and can also be used for the laboratory follow up of patients treated for TYR 1.