For real-time control of ozonation processes in water works, a sequencing batch reactor was constructed to measure the ozone decay rate constant (kO3) in short time intervals of about 15 min. The batch reactor is filled during the production process, immediately after dissolving ozone in water by a static mixer. On the basis of kO3 and the initial ozone concentration ([O3]0), and the experimentally determined ratio of the concentrations of •OH radicals to ozone (Rct), the degradation of micropollutants in ozone reactors (modeled as Continuously Stirred Tank Reactors - CSTRs) were calculated for compounds with known reaction rate constants with ozone and •OH radicals. Calculated degradation of atrazine, iopromide, benzotriazole and acesulfame are in good agreement with measured data. For acesulfame the following rate constants were determined in this study at 20 oC: reaction rate constant with ozone = 88 M−1s−1, reaction rate constant with •OH radical = 4.55 × 109 M−1s−1. For the ozone reaction an activation energy of 35 kJ/mol was determined. Similarly to micropollutants, the relative inactivation of microorganisms (N/N0) can be calculated based on the inactivation rate constant for ozone and if applicable the lag phase. The pI-value (= −logN/N0) was introduced and implemented in the process management system to calculate online the log inactivation of reference microorganisms such as B. subtilis spores. The system was tested for variation of pH (6.5–8.5), DOC (1.2–4.2 mg/L) flowrate 3.2–12 m3/h and temperature (5.7–9 oC). Furthermore, a given pI-value, e.g. 1 for a 1-log inactivation of B. subtilis spores, can be set as control parameter in the process management system. The ozone gas flow is then adjusted until the set pI-value is reached. The process control concept was validated with B. subtilis spores. Generally, a good agreement was found between calculated and measured inactivation data. It was also demonstrated, that a constant ozone residual may lead to insufficient disinfection or overdosing of ozone. The new process control concept for ozonations based on onsite measurement of the ozone decay rate constant and the pI-value allows to assess disinfection and degradation processes quantitatively in real-time.
The hydraulics of water and wastewater treatment reactors has a major impact on their performance and control. The residence time distribution as a measure for the hydraulics represents macroscopic mixing in an integrated way with no spatial information. However, with regard to optimal sensor location for process control and for process optimisation measures, spatial information about macro-mixing is helpful. Spatially distributed measurements of reactive tracers can provide this information. In this paper we generally discuss how reactive tracers can be used to detect and characterize distinct large scale flow structures. It is shown that tracer substances are particularly suited if their reaction time scale is similar to the time scale of the large scale flow structure. For nitrifying activated sludge systems, ammonium is identified to be a suitable tracer. In a comprehensive experimental study at a real aeration tank, two distinct large scale flow features were identified by distributed ammonium measurements. Flow velocity measurements using acoustic Doppler velocimetry clearly supported the nature of these flow field anomalies. Ion-selective electrodes are a well suited device for ammonium measurements providing the temporal resolution that is needed for such an analysis.
Due to the high energy input of aeration, the spatial distribution of air diffusers largely determines the flow field in aeration tanks. This has consequences on the efficiency of the aeration system, the performance of the aeration tank and on tank operation and control. This paper deals with these effects applying both Computational Fluid Dynamics (CFD) enhanced with a biokinetic model and full scale validation using velocity and reactive tracer measurements with high temporal and spatial resolution. It is shown that small changes in the diffuser arrangement drastically change the overall flow field. Using different aeration patterns in the same tank may lead to large scale instabilities in the flow field that lower plant performance and produce strong variations in concentration signals impeding their use for plant control. CFD is a valuable tool to analyze the interaction of flow field and aeration and their effects on plant performance and operation. But, in complex flow situations experimental validation is needed and strongly suggested.
Reactor modeling is of major interest in environmental technology. In this context, new contaminants with higher degradation requirements increase the importance of reactor hydraulics. CFD (Computational Fluid Dynamics) may meet this challenge but is expensive for everyday use. In this paper, we provide research and practice with a methodology designed to automatically reduce the complexity of such a high-dimensional flow model to a compartmental model. The derivation is based on the concentration field of a reacting species which is included in the steady state CFD simulation. While still capturing the most important flow features, the compartmental model is fast, easy to use, and open for process modeling with yet unknown compounds. The inherent overestimation of diffusion by compartmental models has been corrected by locally adjusting turbulent fluxes. We successfully applied the methodology to the ozonation process and experimentally verified it with tracer experiments. The loss of information was quantified as a deviation from CFD performance prediction for different reactions. With increasing discretisation of the compartmental model, these deviations diminish. General advice on the necessary discretisation is given.
Extraneous flows in wastewater collection systems are conventionally evaluated solely on the consideration of discharge hydrographs, which often involves a great degree of subjectivity and oversimplification. To obtain reliable information on the material fluxes within the urban environment, the use of intrinsic tracers can be the optimal choice. We demonstrate the successful use of naturally occurring stable isotopes of water (O-18/O-16 and D/H) to accurately quantify extraneous discharge of groundwater in a combined sewer network. Fresh water supply from a distant hydrological regime provided usable isotopic separations between drinking water (proxy for real foul sewage) and local groundwater (proxy for sewer infiltration) of 1.8 parts per thousand in delta 18O and 11.7 parts per thousand in delta H-2. Diurnal variation of wastewater isotopic composition reflected both the varying rates of foul sewage production and irregular dispersion effects in the pipe network. The latter suggest the existence of larger cumulative backwater zone volumes, which have not been attended to yet. Infiltrating groundwater contributed 39% (95% confidence interval = +/- 2.5%) of the total daily dry weather wastewater discharge. This paper discusses all relevant aspects for practical application of the method. It presents a comprehensive framework for uncertainty analysis and details on the detection and discrimination of possibly interfering effects.