Using novel metallic magnetic calorimeter detectors at the CRYRING@ESR, we recorded X-ray spectra of stored and electron cooled helium-like uranium (U^90+) with an unmatched spectral resolution of close to 90 eV. This allowed for an accurate determination of the energies of all four components of the Kα transitions in U^90+. We find good agreement with state-of-the-art bound-state QED calculations for the strong-field regime. Our results do not support any systematic deviation between experiment and theory in helium-like systems, the presence of which was subject of intense debates in recent years.
We have performed systematic measurements of the resistive cooling behavior of bunches of highly charged ions in a Penning trap after injection from an external source. In particular, we have been able to measure the exponential cooling rate of the axial center -of -mass motion and experimentally show its linear dependence on the ion number within the bunch, as expected from theory. The common center -of -mass energy of the ions is reduced by more than four orders of magnitude on the time scale of milliseconds while the single -ion cooling occurs on the scale of seconds, representing a highly effective way to remove the dominating part of the ion kinetic energy.
We present a non-destructive electronic detector for stored charged particles in a Penning trap that uses a symmetric electrode arrangement for signal pickup and a resonator without tap. This system has advantageous off-resonance features which are demonstrated by means of detection and cooling measurements with highly charged ions in a cryogenic Penning trap. In particular, it allows for particle detection across a wide range of frequencies that is not concomitant with cooling and offers a novel way to tune a trap with the help of non-destructive measurements on large particle ensembles.
We have developed and operated an electronic system for the non-destructive detection and cooling of charged-particle bunches that are captured and confined in a Penning trap, together with methods for the evaluation of corresponding measurements that allow for a detailed characterization of each individual particle bunch. Once calibrated, from a single measurement of the particles’ induced electronic signal as a function of time directly upon capture, the setup and method allow for a fast determination of the initial and final absolute particle energies, of the cooling rate, and of the absolute number of particles in the bunch. We demonstrate this with highly charged ions (Ne8+) that are injected into the Penning trap of the HILITE experiment.
We report on a new experimental approach for the Doppler correction of X-rays emitted by heavy ions, using novel metallic magnetic calorimeter detectors which uniquely combine a high spectral resolution with a broad bandwidth acceptance. The measurement was carried out at the electron cooler of CRYRING@ESR at GSI, Darmstadt, Germany. The X-ray emission associated with the radiative recombination of cooler electrons and stored hydrogen-like uranium ions was investigated using two novel microcalorimeter detectors positioned under 0∘ and 180∘ with respect to the ion beam axis. This new experimental setup allowed the investigation of the region of the N, M → L transitions in helium-like uranium with a spectral resolution unmatched by previous studies using conventional semiconductor X-ray detectors. When assuming that the rest-frame energy of at least a few of the recorded transitions is well-known from theory or experiments, a precise measurement of the Doppler shifted line positions in the laboratory system can be used to determine the ion beam velocity using only spectral information. The spectral resolution achievable with microcalorimeter detectors should, for the first time, allow intrinsic Doppler correction to be performed for the precision X-ray spectroscopy of stored heavy ions. A comparison with data from a previous experiment at the ESR electron cooler, as well as the conventional method of conducting Doppler correction using electron cooler parameters, will be discussed.
We have developed and operated an electronic detection system for the non-destructive single-pass detection of bunches of charged particles in a beamline that allows for a measurement of their lateral position with respect to the central beamline axis on a shot-to-shot basis. It provides all features of our related development reported in Kiffer et al. (Rev Sci Instrum 90:113301, 2019), namely single-pass measurement of bunch length, kinetic energy and absolute charge, and is additionally designed to provide the lateral position of bunches with sub-mm accuracy. We show the setup, associated methods and provide characterizing measurements with bunches of highly charged ions in the keV regime of kinetic energy that demonstrate the capabilities and show a typical application.
We have conceived and built the HILITE (High-Intensity Laser-Ion Trap Experiment) Penning-trap setup for the production, confinement and preparation of pure ensembles of highly charged ions in a defined quantum state as a target for various high-intensity lasers. This enables a broad suite of laser-ion interaction studies at high photon energies and/or intensities, such as non-linear photo-ionisation studies. The setup has now been used to perform experiments at one such laser facility, namely the FLASH Free-Electron Laser at DESY in Hamburg, Germany. We describe the experimental possibilities of the apparatus, the results of the first measurements and future experiments at other laser facilities.
We present a Penning-trap-based setup for the study of light-matter interactions in the high-power and/or high-intensity laser regime, such as multi-photon ionization and field ionization. The setup applies ion-cloud formation techniques to highly charged ions to the end of specific target preparation, as well as non-destructive detection techniques to identify and quantify the interaction educts and products.
Synopsis We present non-destructive single-pass ion bunch detection and characterisation by measuring the induced image charge in a detection electrode. The presented technique allows direct determination of ion kinetic energy, absolute ion number and spatial ion bunch length. We will show the results of corresponding measurements with bunches of low-energy highly charged ions and discuss the minimum detectable number of charges.
Detailed investigations of laser–ion interactions require well‐defined ion targets and detection techniques for high‐sensitivity measurements of reaction educts and products. To this end, we have designed and built the High‐Intensity Laser‐Ion Trap Experiment Penning trap setup, which features various ion‐target preparation techniques including selection, cooling, compression, and positioning as well as destructive and non‐destructive measurement techniques to determine the number of stored ions for all charge states individually and simultaneously. We have recently performed first commissioning experiments of ion deceleration and dynamic ion capture with highly charged ion bunches from an electron beam ion source. We have characterized our single‐pass non‐destructive ion counter in detail and were able to determine the ion velocity as well as the number of ions from the signals acquired.
We have devised an experimental method and apparatus for the simultaneous nondestructive determination of the absolute ion number, ion kinetic energy, and length of bunches of charged particles. We have built and operated a corresponding electronic detector that is based on induced charges and their subsequent low-noise amplification at cryogenic temperatures. We have performed measurements with bunches of low-energy highly charged ions from an electron-beam ion source that show the capability of the methods and their implementation. We discuss requirements for, and applications of, such detectors with a particular view on the obtainable information and their sensitivity.