Quantitative ultrasound parameters offer effective tools to evaluate microstructural changes in liver tissue and noninvasively assess tissue health. We examined the relationship between steatotic liver disease severity, measured by the Total Severity Score (TSS), and the structure function (SF), a frequency-dependent ultrasound backscatter metric. TSS was calculated on a 0-14 scale from histological evaluation by a pathologist of fibrosis, inflammation, and steatosis in hematoxylin and eosin-stained liver slides. A total of 274 regions of interest (ROIs) were examined from histopathology liver specimens acquired from 49 human subjects. SF was calculated for every ROI over a spatial frequency range of 3-80 MHz using histology-determined cell nuclei positions. Results revealed a strong relationship between SF and TSS across all analyzed ROIs, and distinct frequency-dependent patterns emerged across TSS groups. Statistical analysis showed significant differences between TSS 0 and TSS 1-3 for the frequency range of 4.5 to 9.0 MHz, and between TSS 1-3 and TSS 4-6 for the frequency ranges of 3.0 to 9.0 MHz and 32.5 to 80.0 MHz. TSS groups 4-6 and 7-14 did not differ significantly, indicating a possible plateau in ultrasound response at later disease stages. These findings help lay the foundation for establishing SF as a potential ultrasonic biomarker for identifying and distinguishing steatotic liver disease stages in vivo.
Background Evaluating peripheral nerve response after injury or repair remains a critical clinical challenge. Current medical imaging approaches provide limited insight into the degenerative or regenerative environment of affected nerves. Purpose To assess the efficacy of ultrashort echo time (UTE) quantitative MRI (qMRI) for evaluating peripheral nerve degeneration and regeneration in rat models of sciatic nerve injury and to assess correlations between UTE qMRI parameters and histologic findings. Materials and Methods In this animal study conducted from November 2022 to December 2023, four experimental groups were created in 6-8-week-old male Lewis rats: (a) sham injury (n = 16), where the sciatic nerve was exposed bilaterally at midthigh level but not transected; (b) injury/early autograft repair (n = 15), where a 10-mm nerve segment was excised, flipped, and resutured into the nerve gap; (c) injury/delayed isograft repair (n = 13), where nerves were transected, capped to prevent spontaneous regeneration, and repaired with a 10-mm isograft 2 months after injury; and (d) no repair, where nerves were capped after excising a 5-mm segment (n = 15). Rats underwent UTE qMRI with a 3-T scanner 1-3 months after surgery or repair. UTE magnetization transfer ratio (MTR), UTE T2*, and UTE T1 were compared using analysis of variance. Correlation analysis evaluated relationships between UTE qMRI-derived parameters and immunohistochemical outcomes. Results UTE MTR (P < .001), UTE T2* (P < .001), and UTE T1 (P < .001) showed lower values in early and delayed repair groups versus the sham group. UTE MTR showed excellent performance in distinguishing the sham group from early and delayed repair groups (mean area under the receiver operating characteristic curve, 0.93 ± 0.03). Histologic analysis demonstrated a moderate positive correlation between myelin area fraction and UTE MTR (r = 0.46; P = .007) and a weak negative correlation between collagen area fraction and UTE MTR (r = -0.38; P = .04). Conclusion UTE MRI-derived MTR effectively distinguished among rat models of peripheral nerve injury and repair and correlated with histologic findings. © RSNA, 2025 Supplemental material is available for this article. See also the editorial by Tan and Argentieri in this issue.
This prospective pilot study examines feasibility of ultrasound (US) imaging methods to evaluate patients with known HCC prior to and after treatment with transarterial radioembolization (TARE). Quantitative backscatter US (QUS) and contrast-enhanced US (CEUS) were successfully performed in the tumor and background liver, using contrast-enhanced (CE) MRI as the reference. Scans were performed pre-TARE and at 6- and 12- or 24-weeks post treatment. Enrollment of 25 patients is planned, but in 15 patients to date (age 47–94, mean 71), all were MRI LI-RADS 5 with tumor diameters 2.1–13.8 cm, had uniformly cirrhotic background liver with low steatosis. Attenuation (AC), backscatter (BC) coefficients, and envelope statistics were computed, with results in the background liver very consistent between acquisition timepoints and patients. Tumor QUS was more heterogeneous but QUS tumor-background contrast was significant. Changes in tumor AC and/or BC post-TARE were significant for all but two patients but variable. Based on MRI data, some tumors may exhibit more delayed response to TARE, so examinations at additional timepoints as well as new patient recruitment are in process. All tumor boundaries corresponded well to CEUS and CE MRI to identify tumors, demarcate tumor size, and boundaries, as well as identify response to therapy.
Wearable ultrasound has the potential to become a disruptive technology enabling new applications not only in traditional clinical settings, but also in settings where ultrasound is not currently used. Understanding the basic engineering principles and limitations of wearable ultrasound is critical for clinicians, scientists, and engineers to advance potential applications and translate the technology from bench to bedside. Wearable ultrasound devices, especially monitoring devices, have the potential to apply acoustic energy to the body for far longer durations than conventional diagnostic ultrasound systems. Thus, bioeffects associated with prolonged acoustic exposure as well as skin health need to be carefully considered for wearable ultrasound devices. This article reviews emerging clinical applications, safety considerations, and future engineering and clinical research directions for wearable ultrasound technology.
Accurate and continuous monitoring of cerebral blood flow is valuable for clinical neurocritical care and fundamental neurovascular research. Transcranial Doppler (TCD) ultrasonography is a widely used non-invasive method for evaluating cerebral blood flow1, but the conventional rigid design severely limits the measurement accuracy of the complex three-dimensional (3D) vascular networks and the practicality for prolonged recording2. Here we report a conformal ultrasound patch for hands-free volumetric imaging and continuous monitoring of cerebral blood flow. The 2 MHz ultrasound waves reduce the attenuation and phase aberration caused by the skull, and the copper mesh shielding layer provides conformal contact to the skin while improving the signal-to-noise ratio by 5 dB. Ultrafast ultrasound imaging based on diverging waves can accurately render the circle of Willis in 3D and minimize human errors during examinations. Focused ultrasound waves allow the recording of blood flow spectra at selected locations continuously. The high accuracy of the conformal ultrasound patch was confirmed in comparison with a conventional TCD probe on 36 participants, showing a mean difference and standard deviation of difference as -1.51 ± 4.34 cm s-1, -0.84 ± 3.06 cm s-1 and -0.50 ± 2.55 cm s-1 for peak systolic velocity, mean flow velocity, and end diastolic velocity, respectively. The measurement success rate was 70.6%, compared with 75.3% for a conventional TCD probe. Furthermore, we demonstrate continuous blood flow spectra during different interventions and identify cascades of intracranial B waves during drowsiness within 4 h of recording.
Objective: To compare the effectiveness of positive pressure (PP) and negative pressure (NP) for reducing gas inclusions in biological tissues in preparation for acoustic imaging. Methods: Eighteen pieces of porcine liver in degassed saline were included in this study. For the PP group (n = 9 samples), a wristwatch waterproof tester was used to pressurize samples to 0.41 MPa (59 psi) for 10 min. For the NP group (n = 9 samples), a desiccator at -0.08 MPa (-12 psi) was used for 30 min. Backscatter coefficients (BSCs) were calculated over the central frequency range of the backscattered spectra and paired-samples t-tests were performed. Results: Utilization of PP resulted in a decrease in BSC for all samples, indicating less gas post-PP (pre-PP -13.0 +/- 4.3 dB [mean +/- SD], post-PP -18.9 +/- 5.0 dB, p = .001). Utilization of NP resulted in an increase in BSC for the majority of samples (pre-NP -14.6 +/- 6.0 dB, post-NP -13.1 +/- 5.3 dB, p = .177). Conclusion: Utilization of a simple PP chamber consistently resulted in a decrease in tissue gas, at lower pressures than previously reported. The vacuum method is ineffective, may result in a paradoxical increase in tissue gas, and may not be recommended for tissue degassing.
To prospectively evaluate ultrasound backscatter coefficients (BSCs) of the supraspinatus and infraspinatus muscles and compare with Goutallier classification on magnetic resonance imaging (MRI). Fifty-six participants had shoulder MRI exams and ultrasound exams of the supraspinatus and infraspinatus muscles. Goutallier MRI grades were determined and BSCs were measured. Group means were compared and the strength of relationships between the measures were determined. Using binarized Goutallier groups (0–2 versus 3–4), areas under the receiver operating characteristic curves (AUROCs) were calculated. The nearest integer cutoff value was determined using Youden’s index. BSC values were significantly different among most Goutallier grades for the supraspinatus and infraspinatus muscles (both p < 0.001). Strong correlations were found between the BSC values and Goutallier grades for the supraspinatus (τb = 0.72, p < 0.001) and infraspinatus (τb = 0.79, p < 0.001) muscles. BSC showed excellent performance for classification of the binarized groups (0–2 versus 3–4) for both supraspinatus (AUROC = 0.98, p < 0.0001) and infraspinatus (AUROC = 0.98, p < 0.0001) muscles. Using a cutoff BSC value of −17 dB, sensitivity, specificity, and accuracy for severe fatty infiltration were 87.0
OBJECTIVES:To implement, examine the feasibility of, and evaluate the performance of quantitative ultrasound (QUS) with a handheld point-of-care US (POCUS) device for assessing liver fat in adults. MATERIALS AND METHODS:This prospective IRB-approved, HIPAA-compliant pilot study enrolled adults with overweight or obesity. Participants underwent chemical-shift-encoded magnetic resonance imaging to estimate proton density fat fraction (PDFF) and, within 1 mo, QUS with a POCUS device by expert sonographers and novice operators (no prior US scanning experience). Radiofrequency data from the liver collected with the POCUS device were analyzed offline using probe-specific calibrations to estimate two QUS parameters: attenuation coefficient (AC) and backscatter coefficient (BSC). Area under the receiver operating characteristic curve (AUC) of each parameter was estimated for classifying presence/absence of hepatic steatosis (defined as PDFF ≥ 5%). Spearman rank correlation between each parameter and PDFF was estimated and its significance assessed. RESULTS:Of 18 participants (mean age, 43 y ± 14; 17 women), 8 had hepatic steatosis (PDFF ≥ 5%). Both AC and BSC classified hepatic steatosis accurately with AUCs of 0.96-0.97 for expert and 0.88-0.89 for novice operators (p < 0.01 for all) and correlated significantly with PDFF with rho's of 0.65-0.69 for expert and 0.58-0.65 for novice operators (p < 0.02 for all). CONCLUSION:QUS can be implemented on a POCUS device and can be performed by expert or novice operators after limited training in adults with overweight or obesity with promising initial results.
This study evaluated the repeatability and reproducibility of using high-frequency quantitative ultrasound (QUS) measurement of backscatter coefficient (BSC), grayscale analysis, and gray-level co-occurrence matrix (GLCM) textural analysis, to characterize human rotator cuff muscles. The effects of varying scanner settings across two different operators and two US systems were investigated in a healthy volunteer with normal rotator cuff muscles and a patient with chronic massive rotator cuff injury and substantial muscle degeneration. The results suggest that BSC is a promising method for assessing rotator cuff muscles in both control and pathological subjects, even when operators were free to adjust system settings (depth, level of focus, and time-gain compensation). Measurements were repeatable and reproducible across the different operators and ultrasound imaging platforms. In contrast, grayscale and GLCM analyses were found to be less reliable in this setting, with significant measurement variability. Overall, the repeatability and reproducibility measurements of BSC indicate its potential as a diagnostic tool for rotator cuff muscle evaluation.
OBJECTIVE:Peripheral nerves remain a challenging target for medical imaging, given their size, anatomical complexity, and structural heterogeneity. Quantitative ultrasound (QUS) applies a set of techniques to estimate tissue acoustic parameters independent of the imaging platform. Many useful medical and laboratory applications for QUS have been reported, but challenges remain for deployment in vivo, especially for heterogeneous tissues. Several phenomena introduce variability in attenuation estimates, which may influence the estimation of other QUS parameters. For example, estimating the backscatter coefficient (BSC) requires compensation for the attenuation of overlying tissues between the transducer and the underlying tissue of interest. The purpose of this study is to extend prior studies by investigating the efficacy of several analytical methods of estimating attenuation compensation on QUS outcomes in the human median nerve. METHODS:Median nerves were imaged at the volar wrist in vivo and beam-formed radiofrequency (RF) data were acquired. Six analytical approaches for attenuation compensation were compared: 1-2) attenuation estimated by applying spectral difference method (SDM) and spectral log difference method (SLDM) independently to regions of interest (ROIs) overlying the nerve and to the nerve ROI itself; 3-4) attenuation estimation by applying SDM and SLDM to ROIs overlying the nerve, and transferring these properties to the nerve ROI; and 5-6) methods that apply previously published values of tissue attenuation to the measured thickness of each overlying tissue. Mean between-subject estimates of BSC-related outcomes as well as within-subject variability of these outcomes were compared among the 6 methods. RESULTS:Compensating for attenuation using SLDM and values from the literature reduced variability in BSC-based outcomes, compared to SDM. Variability in attenuation coefficients contributes substantially to variability in backscatter measurements. CONCLUSION:This work has implications for the application of QUS to in vivo diagnostic assessments in peripheral nerves and possibly other heterogeneous tissues.
Background We investigated the relationship of two commonly used quantitative ultrasound (QUS) parameters, speed of sound (SoS) and attenuation coefficient ( α ), with water and macromolecular contents of bovine cortical bone strips as measured with ultrashort echo time (UTE) magnetic resonance imaging (MRI). Methods SoS and α were measured in 36 bovine cortical bone strips utilizing a single-element transducer with nominal 5 MHz center frequency based on the time of flight principles after accommodating for reflection losses. Specimens were then scanned using UTE MRI to measure total, bound, and pore water proton density (TWPD, BWPD, and PWPD) as well as macromolecular proton fraction and macromolecular transverse relaxation time (T2-MM). Specimens were also scanned using microcomputed tomography (μCT) at 9-μm isometric voxel size to measure bone mineral density (BMD), porosity, and pore size. The elastic modulus (E) of each specimen was measured using a 4-point bending test. Results α demonstrated significant positive Spearman correlations with E ( R = 0.69) and BMD ( R = 0.44) while showing significant negative correlations with porosity ( R = -0.41), T2-MM ( R = -0.47), TWPD ( R = -0.68), BWPD ( R = -0.67), and PWPD ( R = -0.45). Conclusions The negative correlation between α and T2-MM is likely indicating the relationship between QUS and collagen matrix organization. The higher correlations of α with BWPD than with PWPD may indicate that water organized in finer structure (bound to matrix) provides lower acoustic impedance than water in larger pores, which is yet to be investigated thoroughly. Relevance statement This study highlights the importance of future investigations exploring the relationship between QUS measures and all major components of the bone, including the collagenous matrix and water. Investigating the full potential of QUS and its validation facilitates a more affordable and accessible tool for bone health monitoring in clinics. Key points • Ultrasound attenuation demonstrated significant positive correlations with bone mechanics and mineral density. • Ultrasound attenuation demonstrated significant negative correlations with porosity and bone water contents. • This study highlights the importance of future investigations exploring the relationship between QUS measures and all major components of the bone. Graphical Abstract
Ultrasound (US) is an increasingly prevalent and effective diagnostic modality for neuromuscular imaging. Gray-scale B-mode imaging has been the dominant US approach to evaluating nerves qualitatively or making morphometric measurements of nerves, providing important insights into pathological changes for conditions such as carpal tunnel syndrome. Among more recent ultrasound strategies, high-frequency ultrasound (often defined as >15 MHz for clinical applications), quantitative ultrasound and image textural analysis offer promising enhancements for improved and more objective approaches to nerve imaging. In this study, we evaluated the repeatability and reproducibility of backscatter coefficient (BSC) and imaging texture features extracted by gray-level co-occurrence matrices (GLCMs) in homogeneous tissue-mimicking reference phantoms and in median nerves in the wrists of healthy participants. We also investigated several practical sources of variability in the assessment of quantitative parameters, including influences of operators, and participant-to-participant variability. Overall, BSC- and GLCM-based outcomes are highly repeatable and reproducible after operator training, based on measurement of descriptive statistics, repeatability coefficient (RC) and reproducibility coefficient recommended by Quantitative Imaging Biomarker Alliance (QIBA RDC). GLCM parameters appear more reproducible and repeatable than BSC-based parameters in healthy participants in vivo. However, such variability noted here must be compared with the value ranges and variability of the results in pathological nerves, including median nerves afflicted by trauma, overuse syndromes such as carpal tunnel syndrome and after surgical repair.
Aim: This review article describes quantitative ultrasound (QUS) techniques and summarizes their strengths and limitations when applied to peripheral nerves. Methods: A systematic review was conducted on publications after 1990 in Google Scholar, Scopus, and PubMed databases. The search terms "peripheral nerve", "quantitative ultrasound", and "elastography ultrasound" were used to identify studies related to this investigation. Results: Based on this literature review, QUS investigations performed on peripheral nerves can be categorized into three main groups: (1) B-mode echogenicity measurements, which are affected by a variety of post-processing algorithms applied during image formation and in subsequent B-mode images; (2) ultrasound (US) elastography, which examines tissue stiffness or elasticity through modalities such as strain ultrasonography or shear wave elastography (SWE). With strain ultrasonography, induced tissue strain, caused by internal or external compression stimuli that distort the tissue, is measured by tracking detectable speckles in the B-mode images. In SWE, the propagation speed of shear waves, generated by externally applied mechanical vibrations or internal US "push pulse" stimuli, is measured to estimate tissue elasticity; (3) the characterization of raw backscattered ultrasound radiofrequency (RF) signals, which provide fundamental ultrasonic tissue parameters, such as the acoustic attenuation and backscattered coefficients, that reflect tissue composition and microstructural properties. Conclusions: QUS techniques allow the objective evaluation of peripheral nerves and reduce operator- or system-associated biases that can influence qualitative B-mode imaging. The application of QUS techniques to peripheral nerves, including their strengths and limitations, were described and discussed in this review to enhance clinical translation.
Ultrasound (US) is an important imaging tool for skeletal muscle analysis. The advantages of US include point-of-care access, real-time imaging, cost-effectiveness, and absence of ionizing radiation. However, US can be highly dependent on the operator and/or US system, and a portion of the potentially useful information carried by raw sonographic data is discarded in image formation for routine qualitative US. Quantitative ultrasound (QUS) methods provide analysis of the raw or post-processed data, revealing additional information about normal tissue structure and disease status. There are four QUS categories that can be used on muscle and are important to review. First, quantitative data derived from B-mode images can help determine the macrostructural anatomy and microstructural morphology of muscle tissues. Second, US elastography can provide information about muscle elasticity or stiffness through strain elastography or shear wave elastography (SWE). Strain elastography measures the induced tissue strain caused either by internal or external compression by tracking tissue displacement with detectable speckle in B-mode images of the examined tissue. SWE measures the speed of induced shear waves traveling through the tissue to estimate the tissue elasticity. These shear waves may be produced using external mechanical vibrations or internal “push pulse” ultrasound stimuli. Third, raw radiofrequency signal analyses provide estimates of fundamental tissue parameters, such as the speed of sound, attenuation coefficient, and backscatter coefficient, which correspond to information about muscle tissue microstructure and composition. Lastly, envelope statistical analyses apply various probability distributions to estimate the number density of scatterers and quantify coherent to incoherent signals, thus providing information about microstructural properties of muscle tissue. This review will examine these QUS techniques, published results on QUS evaluation of skeletal muscles, and the strengths and limitations of QUS in skeletal muscle analysis.
The publisher regrets than an error was present in Equation (1). The correct equation is:BSCtissue(f)=BSCref(f)Ptissue(f)Pref(f)e4d[αtissue(f)−αref(f)] The publisher would like to apologise for any inconvenience caused. Repeatability, Reproducibility and Sources of Variability in the Assessment of Backscatter Coefficient and Texture Parameters from High-Frequency Ultrasound Acquisitions in Human Median NerveUltrasound in Medicine and BiologyVol. 49Issue 1PreviewUltrasound (US) is an increasingly prevalent and effective diagnostic modality for neuromuscular imaging. Gray-scale B-mode imaging has been the dominant US approach to evaluating nerves qualitatively or making morphometric measurements of nerves, providing important insights into pathological changes for conditions such as carpal tunnel syndrome. Among more recent ultrasound strategies, high-frequency ultrasound (often defined as >15 MHz for clinical applications), quantitative ultrasound and image textural analysis offer promising enhancements for improved and more objective approaches to nerve imaging. Full-Text PDF Open Access
In this study, we evaluated the utility of using high-frequency ultrasound to non-invasively track the degenerative process in a rat model of peripheral nerve injury. Primary analyses explored spatial and temporal changes in quantitative backscatter coefficient (BSC) spectrum-based outcomes and B-mode textural outcomes, using gray level co-occurrence matrices (GLCMs), during the progressive transition from acute to chronic injury. As secondary analyses, correlations among GLCM and BSC spectrum-based parameters were evaluated, and immunohistochemistry were used to suggest a structural basis for ultrasound outcomes. Both mean BSC spectrum-based and mean GLCM-based measures exhibited significant spatial differences across presurgical and 1-month/2-month time points, distal stumps enclosed proximity to the injury site being particularly affected. The two sets of parameters sensitively detected peripheral nerve degeneration at 1-month and 2-month post-injury, with area under the receiver operating charactersitic curve > 0.8 for most parameters. The results also indicated that the many BSC spectrum-based and GLCM-based parameters significantly correlate with each other, and suggested a common structural basis for a diverse set of quantitative ultrasound parameters. The findings of this study suggest that BSC spectrum-based and GLCM-based analysis are promising non-invasive techniques for diagnosing peripheral nerve degeneration.
Background MRI-derived proton density fat fraction (PDFF) is an accurate, reliable, and safe biologic marker for use in the noninvasive diagnosis of hepatic steatosis in patients with nonalcoholic fatty liver disease (NAFLD). Because of the cost and limited availability of MRI, it is necessary to develop an accurate method to diagnose NAFLD with potential point-of-care access. Purpose To compare the diagnostic accuracy of the quantitative US (QUS) fat fraction (FF) estimator with that of the controlled attenuation parameter (CAP) in the diagnosis of NAFLD using contemporaneous MRI-derived PDFF as the reference standard. Materials and Methods Participants with or suspected of having NAFLD were prospectively recruited at the NAFLD Research Center between July 2015 and July 2019. All participants underwent MRI-derived PDFF measurement, transient elastography with CAP measurement, and QUS. QUS FF was derived using computed QUS parameters from the acquired radiofrequency US data using a calibrated reference phantom. The area under the receiver operating characteristic curve (AUC) was calculated to assess the accuracy of QUS FF and CAP in the diagnosis of hepatic steatosis (defined as MRI-derived PDFF ≥ 5%). AUCs were compared using the DeLong test. Results A total of 123 participants were included (mean age, 52 years ± 13 [SD]; 67 [54%] women). Of these participants, 100 (81%) had MRI-derived PDFF of 5% or more. QUS FF had a significantly higher AUC for diagnosis of NAFLD than did CAP (0.92 [95% CI: 0.87, 0.98] vs 0.79 [95% CI: 0.67, 0.90], P = .03). QUS FF had a sensitivity of 98% (98 of 100) and a specificity of 48% (11 of 23). CAP had a sensitivity of 87% (87 of 100) and a specificity of 57% (13 of 23). Conclusion The quantitative US fat fraction estimator is more accurate than the controlled attenuation parameter in the diagnosis of hepatic steatosis in patients with or suspected of having nonalcoholic fatty liver disease. © RSNA, 2022 Online supplemental material is available for this article. See also the editorial by Ito in this issue.
To develop and evaluate deep learning models devised for liver fat assessment based on ultrasound (US) images acquired from four different liver views: transverse plane (hepatic veins at the confluence with the inferior vena cava, right portal vein, right posterior portal vein) and sagittal plane (liver/kidney). US images (four separate views) were acquired from 135 participants with known or suspected nonalcoholic fatty liver disease. Proton density fat fraction (PDFF) values derived from chemical shift-encoded magnetic resonance imaging served as ground truth. Transfer learning with a deep convolutional neural network (CNN) was applied to develop models for diagnosis of fatty liver (PDFF ≥ 5%), diagnosis of advanced steatosis (PDFF ≥ 10%), and PDFF quantification for each liver view separately. In addition, an ensemble model based on all four liver view models was investigated. Diagnostic performance was assessed using the area under the receiver operating characteristics curve (AUC), and quantification was assessed using the Spearman correlation coefficient (SCC). The most accurate single view was the right posterior portal vein, with an SCC of 0.78 for quantifying PDFF and AUC values of 0.90 (PDFF ≥ 5%) and 0.79 (PDFF ≥ 10%). The ensemble of models achieved an SCC of 0.81 and AUCs of 0.91 (PDFF ≥ 5%) and 0.86 (PDFF ≥ 10%). Deep learning-based analysis of US images from different liver views can help assess liver fat.
Objectives To compare the diagnostic accuracy of US shear wave elastography (SWE) and magnetic resonance elastography (MRE) for classifying fibrosis stage in patients with nonalcoholic fatty liver disease (NAFLD). Methods Patients from a prospective single-center cohort with clinical liver biopsy for known or suspected NAFLD underwent contemporaneous SWE and MRE. AUCs for classifying biopsy-determined liver fibrosis stages ≥ 1, ≥ 2, ≥ 3, and = 4, and their respective performance parameters at cutoffs providing ≥ 90% sensitivity or specificity were compared between SWE and MRE. Results In total, 100 patients (mean age, 51.8 ± 12.9 years; 46% males; mean BMI 31.6 ± 4.7 kg/m 2 ) with fibrosis stage distribution (stage 0/1/2/3/4) of 43, 36, 5, 10, and 6%, respectively, were included. AUCs (and 95% CIs) for SWE and MRE were 0.65 (0.54–0.76) and 0.81 (0.72–0.89), 0.81 (0.71–0.91) and 0.94 (0.89–1.00), 0.85 (0.74–0.96) and 0.95 (0.89–1.00), and 0.91 (0.79–1.00) and 0.92 (0.83–1.00), for detecting fibrosis stage ≥ 1, ≥ 2, ≥ 3, and = 4, respectively. The differences were significant for detecting fibrosis stage ≥ 1 and ≥ 2 ( p < 0.01) but not otherwise. At ≥ 90% sensitivity cutoff, MRE yielded higher specificity than SWE at diagnosing fibrosis stage ≥ 1, ≥ 2, and ≥ 3. At ≥ 90% specificity cutoff, MRE yielded higher sensitivity than SWE at diagnosing fibrosis stage ≥ 1 and ≥ 2. Conclusions In adults with NAFLD, MRE was more accurate than SWE in diagnosing stage ≥ 1 and ≥ 2 fibrosis, but not stage ≥ 3 or 4 fibrosis. Key Points • For detecting any fibrosis or mild fibrosis, MR elastography was significantly more accurate than shear wave elastography . • For detecting advanced fibrosis and cirrhosis, MRE and SWE did not differ significantly in accuracy . • For excluding advanced fibrosis and potentially ruling out the need for biopsy , SWE and MRE did not differ significantly in negative predictive value . • Neither SWE nor MRE had sufficiently high positive predictive value to rule in advanced fibrosis .