Digital breast tomosynthesis (DBT) with full-field digital mammography (FFDM) exposes women to a higher radiation dose. A synthetic 2D mammogram (S2D) is a two-dimensional image constructed from DBT. We aim to evaluate the S2D performance when used alone or combined with DBT compared to FFDM alone or with DBT. Studies were included if they recruited screening participants and reported on S2D performance. Studies were excluded if they included symptomatic patients, imaging was for diagnostic purposes, or if participants had a breast cancer history. Meta-analyses for cancer detection rates (CDR) and Specificities were conducted where available. Differences in the performance of imaging modalities were calculated within individual studies, and these were pooled by meta-analysis. Out of 3241 records identified, 17 studies were included in the review and 13 in the meta-analysis. The estimated combined difference in CDRs per thousand among individual studies that reported on DBT plus S2D vs. FFDM and those reporting on DBT plus S2D versus DBT plus FFDM was 2.03 (95% CI 0.81-3.25) and - 0.15 (95% CI -1.17 to 0.86), respectively. The estimated difference in percent specificities was 1.13 (95% CI -0.06 to 2.31) in studies comparing DBT plus S2D and FFDM. In studies comparing DBT plus S2D and DBT plus FFDM, the estimated difference in specificities was 1.08 (95% CI 0.59-1.56). DBT plus S2D showed comparable accuracy to FFDM plus DPT and improved cancer detection to FFDM alone. Integrating S2D with DBT in breast cancer screening is safe and preserves performance.
Purpose: To analyse digital breast tomosynthesis (DBT) reading times in the screening setting, compared to 2D full-field digital mammography (FFDM), and investigate the impact of reader experience and professional group on interpretation times. Method: Reading time data were recorded in the PROSPECTS Trial, a prospective randomised trial comparing DBT plus FFDM or synthetic 2D mammography (S2D) to FFDM alone, in the National Health Service (NHS) breast screening programme, from January 2019-February 2023. Time to read DBT+FFDM or DBT+S2D and FFDM alone was calculated per case and reading times were compared between modalities using dependent T-tests. Reading times were compared between readers from different professional groups (radiologists and radiographer readers) and experience levels using independent T-tests. The learning curve effect of using DBT in screening on reading time was investigated using a Kruskal-Wallis test. Results: Forty-eight readers interpreted 1,242 FFDM batches (34,210 FFDM cases) and 973 DBT batches (13,983 DBT cases). DBT reading time was doubled compared to FFDM (2.09 +/- 0.64 min vs. 0.98 +/- 0.30 min; p < 0.001), and DBT+S2D reading was longer than DBT + FFDM (2.24 +/- 0.62 min vs. 2.04 +/- 0.46 min; p = 0.006). No difference was identified in reading time between radiologists and radiographers (2.06 +/- 0.71 min vs. 2.14 +/- 0.46 min, respectively; p = 0.71). Readers with five or more years of experience reading DBT were quicker than those with less experience (1.86 +/- 0.56 min vs. 2.37 +/- 0.65 min; p = 0.008), and DBT reading time decreased after less than 9 months accrued screening experience (p = 0.01). Conclusions: DBT reading times were double those of FFDM in the screening setting, but there was a short learning curve effect with readers showing significant improvements in reading times within the first nine months of DBT experience.
Recent advances in neoadjuvant systemic therapy (NST) have significantly improved pathologic complete response rates in early breast cancer, challenging the role of axillary lymph node dissection in nose-positive patients. Targeted axillary dissection (TAD) integrates marked lymph node biopsy (MLNB) and tracer-guided sentinel lymph node biopsy (SLNB). The introduction of new wire-free localisation markers (LMs) has streamlined TAD and increased its adoption. The primary endpoints include the successful localisation and retrieval rates of LMs. The secondary endpoints include the pathological complete response (pCR), SLNB, and MLNB concordance, as well as false-negative rates. Seventeen studies encompassing 1358 TAD procedures in 1355 met the inclusion criteria. The localisation and retrieval rate of LMs were 97% and 99%. A concordance rate of 67% (95% CI: 64–70) between SLNB and MLNB was demonstrated. Notably, 49 days (range: 0–272) was the average LM deployment time to surgery. pCR was observed in 46% (95% CI: 43–49) of cases, with no significant procedure-related complications. Omitting MLNB or SLNB would have under-staged the axilla in 15.2% or 5.4% (p = 0.0001) of cases, respectively. MLNB inclusion in axillary staging post-NST for initially node-positive patients is crucial. The radiation-free Savi Scout, with its minimal MRI artefacts, is the preferred technology for TAD.
Objectives: The interpretation of digital breast tomosynthesis (DBT) screening examinations is a complex task for an already overstretched workforce which has the potential to increase pressure on readers leading to fatigue and patient safety issues. Studies in non-medical and medical settings have suggested that changes in blink characteristics can reflect fatigue. The purpose of this study is to investigate the use of blink characteristics as an objective marker of fatigue in readers interpreting DBT breast screening examinations. Methods: Twenty-six DBT readers involved in the UK PROSPECTS trial interpreted a test set of 40 DBT cases while being observed by an eye tracking device from November 2019 to February 2021. Raw data from the eye tracker were collected and automated processing software was used to produce eye blinking characteristics data which were analysed using multiple linear regression statistical models. Results: Of the 26 DBT readers recruited, eye tracking data from 23 participants were analysed due to missing data rendering 3 participants’ data uninterpretable. The mean reading time per DBT case was 2.81 min. There was a statistically significant increase in blinking duration of 0.38 ms/case as the reading session progressed (p < 0.0001). This was the result of a significant decrease in the number of ultra-short blinks lasting ≤50 ms (p = 0.0005) and a significant increase in longer blinks lasting 51–100 ms (p = 0.008). Conclusion Changes in blinking characteristics could serve as objective measures of reader fatigue and may prove useful in the development of DBT reading protocols. Advances in knowledge: Blink characteristics can be used as an objective measure of fatigue; however there is limited evidence of their use in radiological settings. Our study suggests that changes in blink duration and frequency could be used to monitor fatigue in DBT reading sessions.
Objectives Digital breast tomosynthesis (DBT) can improve diagnostic accuracy compared to 2D mammography, but DBT reporting is time-consuming and potentially more fatiguing. Changes in diagnostic accuracy and subjective and objective fatigue were evaluated over a DBT reporting session, and the impact of taking a reporting break was assessed. Materials and methods Forty-five National Health Service (NHS) mammography readers from 6 hospitals read a cancer-enriched set of 40 DBT cases whilst eye tracked in this prospective cohort study, from December 2020 to April 2022. Eye-blink metrics were assessed as objective fatigue measures. Twenty-one readers had a reporting break, 24 did not. Subjective fatigue questionnaires were completed before and after the session. Diagnostic accuracy and subjective and objective fatigue measures were compared between the cohorts using parametric and non-parametric significance testing. Results Readers had on average 10 years post-training breast screening experience and took just under 2 h (105.8 min) to report all cases. Readers without a break reported greater levels of subjective fatigue (44% vs. 33%, p = 0.04), which related to greater objective fatigue: an increased average blink duration (296 ms vs. 286 ms, p < 0.001) and a reduced eye-opening velocity (76 mm/s vs. 82 mm/s, p < 0.001). Objective fatigue increased as the trial progressed for the no break cohort only ( p s < 0.001). No difference was identified in diagnostic accuracy between the groups (accuracy: 87% vs. 87%, p = 0.92). Conclusions Implementing a break during a 2-h DBT reporting session resulted in lower levels of subjective and objective fatigue. Breaks did not impact diagnostic accuracy, which may be related to the extensive experience of the readers. Clinical relevance statement DBT is being incorporated into many mammography screening programmes. Recognising that reporting breaks are required when reading large volumes of DBT studies ensures this can be factored in when setting up reading sessions. Trial registration Clinical trials registration number: NCT03733106 Key Points • Use of digital breast tomosynthesis (DBT) in breast screening programmes can cause significant reader fatigue. • The effectiveness of incorporating reading breaks into DBT reporting sessions, to reduce mammography reader fatigue, was investigated using eye tracking. • Integrating breaks into DBT reporting sessions reduced reader fatigue; however, diagnostic accuracy was unaffected.
Background: The early detection of breast cancer (BrC) is associated with improved survival. We describe a blood-based breast cancer detection test based on functional enrichment of breast-adenocarcinoma-associated circulating tumor cells (BrAD-CTCs) and their identification via multiplexed fluorescence immunocytochemistry (ICC) profiling for GCDFP15, GATA3, EpCAM, PanCK, and CD45 status. Methods: The ability of the test to differentiate BrC cases (N = 548) from healthy women (N = 9632) was evaluated in a case–control clinical study. The ability of the test to differentiate BrC cases from those with benign breast conditions was evaluated in a prospective clinical study of women (N = 141) suspected of BrC. Results: The test accurately detects BrAD-CTCs in breast cancers, irrespective of age, ethnicity, disease stage, grade, or hormone receptor status. Analytical validation established the high accuracy and reliability of the test under intended use conditions. The test detects and differentiates BrC cases from healthy women with 100% specificity and 92.07% overall sensitivity in a case–control study. In a prospective clinical study, the test shows 93.1% specificity and 94.64% overall sensitivity in differentiating breast cancer cases (N = 112) from benign breast conditions (N = 29). Conclusion: The findings reported in this manuscript support the clinical potential of this test for blood-based BrC detection.
Breast Cancer Research 23(2) X-Ray scatter is a well-known problem in mammography and DBT, complicating image presentation and impacting lesion contrast.Physical anti-scatter grids are commonly used to minimise the negative effects, but with the penalty of increased radiation dose.However, rather than being a problem to be eliminated, the scatter signal can be used advantageously to provide an information channel which can be harnessed to extract additional clinical value from DBT reconstructions.A physics model of the mammography system can be used to build, in real time, a composition and thickness map of the breast.This information can be used to correct for X-ray scatter without the need for a grid, resulting in reduced radiation dose and simplified system hardware.SDNR measurements following the EUREF guideline method indicate grid equivalence at a 25% dose reduction for breast equivalent thicknesses up to 90mm.In DBT, where it is less common for vendors to manage X-ray scatter, the quality of synthetic 2D images can also be improved, particularly for thicker breasts.The model also facilitates reconstruction of 3D images with near isotropic resolution.Avoiding depth artefacts typical in standard DBT reconstruction methods may help in discriminating between features in dense breasts; the composition information may facilitate differentiation between glandular tissue, cysts, and other materials in the breast including contrast agent.We will provide an overview of the methodology and some early results demonstrating the potential of these software tools.We will also present a vision for some of the emerging opportunities arising from these techniques.
Introduction: Myofibroblastoma (MFB) of the breast is an uncommon benign indeterminate mesenchymal tumour with equivocal radiological, immunochemical and varying histopathological morphology. Their accurate diagnosis and treatment presents a challenge. In light of its rarity, diagnostic excision with a margin to reduce the risk of local re-occurrence is recommended however subsequent management is uncertain.