The use of anabolic steroid hormones as growth promoters in feed for farm animals has been banned in the European Union since 1988 on the basis of Council Directive 96/22/EC. However, there is still ongoing monitoring and reporting of positive findings of these banned substances in EU countries. The aim of this work was to investigate the efficacy and discriminatory ability of metabolic fingerprinting after the administration of 17β-testosterone esters to pigs. Plasma and urine samples were chromatographically separated on a Hypersil Gold C18 column. High resolution mass spectrometry metabolomic fingerprints were analysed on a hybrid mass spectrometer Q-Exactive. Three independent multivariate statistical methods, namely principal component analysis, clustre analysis, and orthogonal partial least squares discriminant analysis showed significant differences between the treated and control groups of pigs even 14 days after the administration of the hormonal drug. Plasma samples were also analysed by a conventional quantitative analysis using liquid chromatography with tandem mass spectrometry and a pharmacokinetic curve was constructed based on the results. In this case, no testosterone residue was detected 14 days after the administration. The results clearly showed that a metabolomics approach can be a useful and effective tool for the detection and monitoring of banned anabolic steroids used illegally in pig fattening.
Brassinosteroids (BRs) are plant-specific steroid hormones that play essential roles in the regulation of many important physiological processes in plant life. Their extremely low concentrations (~pmoles/g FW) in plant tissue and huge differences in polarity of individual members within the BR family hamper their detection and quantification. To address this problem, an immunoaffinity sorbent with broad specificity and high capacity for different BR metabolites containing a monoclonal antibody (mAb) against a BR spacer (20S)−2α,3α-dihydroxy-7-oxa-7α-homo-5α-pregnane-6-one-20 carboxylic acid (BR4812) was used for the rapid and highly selective isolation of endogenous BRs containing a 2α,3α-diol in ring A from minute plant samples. This enrichment procedure was successfully applied as a sample preparation method prior to quantitative analysis of BRs in real plant tissues by ultra-high performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS). Use of immunoaffinity chromatography (IAC) increased the sensitivity of the UHPLC-MS/MS analysis owing to improvements in the BR signal-to-noise ratio (S/N) and matrix factor (MF). Although MF values of BRs analyzed in classical samples ranged from 8.9% to 47.4%, MF values for the IAC purified samples reached 44.5–96.6%. Thus, the developed IAC-UHPLC-MS/MS approach was shown to be a simple, robust, effective and extremely fast procedure requiring minute amounts of plant samples suitable for the quantitative profiling of many BR metabolites, helping to overcome the major problems associated with their determination in very complex plant matrices.
The herbicide 2,4-D exhibits an auxinic activity and therefore can be used as a synthetic and traceable analog to study auxin-related responses. Here we identified that not only exogenous 2,4-D but also its amide-linked metabolite 2,4-D-Glu displayed an inhibitory effect on plant growth via the TIR1/AFB auxin-mediated signaling pathway. To further investigate 2,4-D metabolite conversion, identity and activity, we have developed a novel purification procedure based on the combination of ion exchange and immuno-specific sorbents combined with a sensitive liquid chromatography-mass spectrometry method. In 2,4-D treated samples, 2,4-D-Glu and 2,4-D-Asp were detected at 100-fold lower concentrations compared to 2,4-D levels, showing that 2,4-D can be metabolized in the plant. Moreover, 2,4-D-Asp and 2,4-D-Glu were identified as reversible forms of 2,4-D homeostasis that can be converted to free 2,4-D. This work paves the way to new studies of auxin action in plant development.
High throughput GC-MS methods for quantification of alkylresorcinols (AR), biomarkers of whole grain wheat and rye intake, in plasma and adipose tissue and their metabolites in urine were developed and optimised. Alkylresorcinols in plasma (200 mu L) and adipose tissues (10-50 mg) were extracted with diethyl ether, whereas main AR metabolites such as DHBA and DHPPA and newly identified metabolites in urine (50 mu L) were extracted with ethyl acetate after enzymatic deconjugation. All extracts were purified on OASIS-MAX solid phase extraction cartridges. Plasma and adipose tissue sample extracts were then derivatised with trifluoroacetic anhydride and reconstituted in undecane, whereas AR metabolites in urine samples were derivatised with BSTFA+TMCS (99:1, v/v, 100 mu L). Prepared samples were quantified by GC-MS (EI-SIM). Analysis of all compounds in the different matrices showed good selectivity, sensitivity, linearity, precision (<15% within and between batches), adequate recovery (75-108%), and short total run time (10-12 min). The methods developed are applicable to large-scale sample sets such as epidemiological studies. (C) 2015 The Authors. Published by Elsevier B.V.
The analytical performance and evaluation of a kit-based ELISA for the determination of acrylamide in fried potato and corn chip samples are described. The sample homogenate is subjected to clean-up using SPE, followed by analyte derivatization and ELISA detection. Accuracy, precision and linearity of the ELISA procedure have been validated using spiked samples. Analytical recovery ranged from 91.8% to 96.0% with coefficients of variation below 15%. Good linearity over a wide range of dilution and minimal assay drift was observed within a microtiter plate. IC50 value of the calibration curve was 110ng/mL, with the limit of detection about 5ng/mL and dynamic range from 10 to 1000ng/mL. The high specificity of the ELISA was demonstrated by cross-reactivity study using 11 potential cross-reactants. A good correlation between the results obtained from the ELISA and GC–MS within the concentration range 120–1500μg/kg was found in the chip samples (r=0.992, n=120). The data demonstrate that the evaluated and validated ELISA has a potential utility in a quick, simple and reliable acrylamide screening analysis for the medium- and large-sized food companies, as well as for residue laboratories and the food industry dealing with improving the chemical safety of foods available to the consumer.
An electrochemical immunoassay for neopterin was developed using recently produced specific antibodies immobilized to protein A-coated magnetic beads in combination with differential pulse voltammetry and screen-printed array of electrodes. Neopterin–alkaline phosphatase conjugate was used as label in a competitive assay format. Multiplexed analysis of neopterin was demonstrated by replacing the traditional ELISA with electrochemical detection and the traditional plastic wells with screen-printed array of electrodes. The optimized electrochemical method, based on polyclonal antibodies, reached a limit of detection of 0.008ng/mL with an average RSD %=10. Serum samples collected from patients with sepsis, healthy volunteers and other patients without a confirmed clinical diagnosis were also analyzed. The obtained results, compared with those of a commercial ELISA kit, had a significant correlation, showing the possibility to distinguish among the serum samples from ill or healthy subjects.
Alkylresorcinols (ARs) are amphiphilic phenolic lipids and their two main metabolites, 3-(3,5-dihydroxyphenyl)-propanoic acid (DHPPA) and 3,5-dihydroxybenzoic acid (DHBA), can be used as biomarkers of whole grain wheat and rye intake. The aim of this study was to develop antibodies against DHBA and DHPPA for use in ELISA analysis. Good calibration curves were obtained for ELISA using alkaline phosphatase (AP) conjugates. The highest sensitivity for DHPPA was found using a reagent combination of anti-DHPPA-BSA and DHPAA-AP in a direct ELISA (IC50=1.5μmol/L), and for DHBA using a reagent combination of anti-DHBA-OV and DHBA-AP (IC50=1.3μmol/L). Calibration was conducted in the linear range (0.3-27.4μmol/L), with limit of detection (LOD) 0.1μmol/L. Intra and inter CVs was in the range of 0.7-7.2% and 5.1-11.5%, respectively, for DHPPA and 1.3-9.4% and 3.5-20%, respectively, for DHBA. Mean recovery was 104% for DHPPA and 102% for DHBA. The ELISA method developed was then used for analysis of 120 urine samples from free-living men and women that had previously been analysed by gas chromatography-mass spectrometry (GC-MS). ELISA produced several-fold higher values than GC-MS. Application of high-resolution Orbitrap mass spectrometry (HR Orbitrap MS) allowed several compounds, including novel putative AR metabolites, to be identified, synthesised and confirmed as compounds with high ELISA cross-reactivity.
Recent developments in spectrally encoded microspheres (SEMs)-based technologies provide high multiplexing possibilities. Most SEMs-based assays require a flow cytometer with sophisticated fluidics and optics. A new imaging super-paramagnetic SEMs-based alternative platform transports SEMs with considerably less fluid volume into a measuring chamber. Once there SEMs are held in a monolayer by a magnet. Light-emitting diodes (LEDs) are focused on the chamber to illuminate the SEMs - instead of lasers and they are imaged by a charge-coupled device (CCD) detector, offering a more compact sized, transportable and affordable system. The feasibility of utilising this system to develop a 3-plex SEMs-based imaging immunoassay (IMIA) for the screening of persistent organic pollutants (POPs) was studied. Moreover the performance characteristics of 3-plex IMIA were critically compared with the conventional 3-plex flow cytometric immunoassay (FCIA). Both SEM technologies have potential for the multiplex analysis of polychlorinated biphenyls (PCBs), polybrominated diphenyl ethers (PBDEs) and polycyclic aromatic hydrocarbons (PAHs) in buffer and fish extract with insignificant differences in assay sensitivities. Furthermore, we developed a faster and simpler, modified QuEChERS-like generic POPs extraction from tilapia fillet using sodium hydrogen carbonate as one of the salt additives and dispersive solid-phase extraction (dSPE) as a clean-up. Finally, a preliminary in-house validation using 40 different blank and spiked tilapia fillet samples was performed in both systems and the results obtained were critically compared. The lower-cost imaging SEMs-based system performed similarly to the original flow cytometer and, in combination with the new quicker QuEChERS-like extraction, it has high potential for future rapid screening of POPs in several other sample matrices such as other fish species, vegetable refined oils and environmental samples.
Sulfonamides are widely used in treatment of animals and humans but pose a risk as environmental pollutants. An analysis of 1588 publications focused on sulfonamides is presented here. The review deals with environmental pollution with sulfonamides, described in papers indexed in the database Web of Science from 1938 to 2011. More in depth details are presented regarding publication activity during the last ten years in which 1255 papers have been published by authors from 1100 institutions. Papers, published during the last three years and mainly in 2011, are listed in comprehensive tables, sorted according to five criteria: reviews, contaminated niches, risk of contamination, sulfonamide transformation and methods of analysis. Key words and shortened abstracts direct the reader to the topics of interest. Hyperlinks to full papers, published in open access journals, are another aid in knowledge dissemination. This design of the review article allows easy navigation through vast amounts of information. Finally, a case report illustrates experiences from the author's laboratory with sulfamethazine determination in pig slurry by ELISA. The reported results highlight the need for updating the legal directives for environmental protection.
Fundamental immunological principles and factors influencing production strategies for antibodies used as reagents in analytical and diagnostic methods are highlighted. A role of the peptide-protein design for an antibody formation, covering particularly epitope selection, peptide and protein chemistry, carrier-protein conjugation including multiple antigen protein approach are described. Special attention is paid to hapten design and production of antibodies against molecules having low-molecular character. Critical stages in polyclonal and monoclonal antibody development as well as practical hints for their production are discussed.
Monoclonal antibodies against widely used herbicide 2,4-D were produced by hybridomas from fusion of murine myeloma cells and spleencells isolated from BALB/c mice immunized with hapten conjugated via the carboxyl group to thyroglobulin. The monoclonal antibodies was subsequently characterized by competitive ELISA employing rabbit anti-mouse immunoglobulin to capture antibody from the ascites fluid and the peroxidase conjugate as a detection component. The cross-reactivity of the antibodies was defined on the bases of competitive study with other 2,4-D structural analogs. The selected broad-specific monoclonal antibodies (E2/G2) were coupled to Affi-Gel (R) 10 and immunoaffinity columns were prepared. These columns were subsequently used for immunoaffinity isolation of 2,4-D and its metabolites from plant extracts.
Persistent organic pollutants (POPs) are environmental and food-related contaminants of global public health concern and known to be carcinogenic and endocrine disruptors. Their monitoring is essential, and an easy-to-use, rapid, and affordable multianalyte screening method with simplified sample preparation can be a valuable tool prior to instrumental analysis. For this purpose, a flow cytometric immunoassay (FCIA), based on a spectrally encoded microbeads technology, was developed for the multiplex detection of polycyclic aromatic hydrocarbons (PAHs), polychlorinated biphenyls (PCBs), and polybrominated diphenyl ethers (BDEs) in buffer and fish extracts. The sensitivities of the assays in the three-plex FCIA format were similar to the individual FCIAs for the marker compounds benzo[a]pyrene (BaP), 3,3',4,4'-tetrachlorobiphenyl (PCB77), and 2,2',4,4'-tetrabromodiphenyl ether (BDE47) in buffer with IC50 values of 0.4, 20, and 2 mu g L-1, respectively. Apart from the three markers, we could detect at least 14 other POPs. Extracts of fish with different fat content, prepared with a simplified extraction and cleanup procedure, had an insignificant influence on the overall three-plex FCIA performance, with the exception of some impact on the PAHs. detection. The performance of the three-plex FCIA, in combination with the simple extraction procedure, is adequate for regulatory control in accordance with the required limits.
The sensitivity of antibody/hapten-based labeling systems is limited by the natural affinity ceiling of immunoglobulins. Breaking this limit by antibody engineering is difficult. We thus attempted a different approach and investigated if the so-called bridge effect, a corecognition of the linker present between hapten and carrier protein during antibody generation, can be utilized to improve the affinity of such labeling systems. The well-known haptens 2,4-dinitrophenol (2,4-DNP) and 2,4-dichlorophenoxyacetic acid (2,4-D) were equipped with various linkers, and the resulting affinity change of their cognate antibodies was analyzed by ELISA. Anti-2,4-DNP antibodies exhibited the best affinity to their hapten when it was combined with aminobutanoic acid or aminohexanoic acid. The affinity of anti-2,4-D antibodies could be enhanced even further with longer aliphatic spacers connected to the hapten. The affinity toward aminoundecanoic acid-2,4-D derivatives, for instance, was improved about 100-fold compared to 2,4-D alone and yielded detection limits as low as 100 amoles of analyte. As the effect occurred for all antibodies and haptens tested, it may be sensible to implement the bridge effect in future antibody/hapten-labeling systems in order to achieve the highest sensitivity possible.
Polar organic compound integrative samplers (POCIS) in combination with instrumental techniques such as LC-MS-MS were previously used to monitor environmental pollutants but the performance of alternative immunochemical methods such as ELISA (enzyme-linked immunosorbent assay) has been explored less. In the present study, POCIS technology was applied to surface water sampling in the Czech Republic, and ELISA was used as a detection technique for the herbicide atrazine. In the first study, 28 samples from streams around small municipal waste water treatment plants (WWTPs) were collected using two different devices (POCISpest and POCISpharm) over the course of 21 days. Elevated atrazine concentrations (up to 25 ng per POCIS) were found in samples down-stream of WWTPs. This observation was also confirmed in another two year study (4 sampling periods) investigating 7 river sites around a major city of Brno as well as the inlet and outlet of the city's WWTP. High atrazine levels were systematically determined at the outlet from the WWTPs (120-605 ng per POCIS). A decreasing trend in the atrazine concentrations in rivers around the city of Brno has been observed, with the highest levels observed within the first sampling period in spring 2007 (100-600 ng per POCIS, with an extreme value of 2760 ng per POCIS). Results of the atrazine ELISA were closely correlated with LC-MS/MS, which confirmed good applicability of ELISA as a cost-effective screening tool.
Sulfonamide antibiotics coming from both human and veterinary medicine are among the most common emerging pollutants in freshwater. The present paper shows the successful application of passive sampling using POCIS in combination with an immunochemical ELISA technique and HPLC/MS/MS analysis to study the distribution of sulfonamides in streams around small towns in the Czech Republic, as well as around a major agglomeration of the city of Brno, including its waste water treatment plant (WWTP). Results indicated the presence of sulfonamides at most studied sites with concentrations ranging from <20 up to 736 ng of sulfamethoxazole equivalents per POCIS. Very high levels were detected in both the influent and effluent of the Brno WWTP with maxima > 8000 ng SMX per POCIS. All samplers collected down-stream of the studied towns and WWTPs clearly showed an increase in sulfonamide drug residues. Higher concentrations were determined in rivers at the city of Brno agglomeration. In agreement with other available studies, these findings indicate low efficiency of conventional WWTPs to eliminate polar pharmaceuticals such as sulfonamides. Good performance and correlation with the LC/MS results, as well as ease of use, indicate good potential for the immunochemical ELISA technique to become the screening tool for sulfonamide determination in surface waters including passive samplers.
Neopterin is a valuable biomarker of cellular immunity associated with various pathological situations such as viral and bacterial infections, autoimmune, cardiovascular, neurodegenerative and malignant disorders. To produce specific antibodies against neopterin for a rapid multi-biomarker-based diagnosis, a novel hapten derivative was synthesized and attached to carrier proteins. The thoroughly characterized conjugates were used for immunization of BALB/c mice and rabbits. The produced monoclonal antibody reached in both direct and indirect enzyme-linked immunosorbent assay (ELISA) format LoD of 0.18 and 0.45 μg L−1, respectively, and was a superior immunoreagent for further biosensor developments with regard to assay sensitivity and material availability. The best polyclonal antibody was somewhat more sensitive in direct ELISA with LoD of 0.05 μg L−1. The optimized ELISA method was evaluated with blood samples collected from patients with renal insufficiency, patients with sepsis, patients without confirmed clinical diagnosis, and healthy volunteers. In plasma samples, neopterin concentrations ranging from 3.2 to 103 μg L−1 could be determined with the monoclonal ELISA whereas twofold lower results were obtained with the polyclonal ELISA. A satisfactory correlation of results was found between the polyclonal ELISA and IBL Neopterin ELISA kit within the concentration range 0.5–16 μg L−1 (R = 0.874; n = 40), and slightly lower correlation was found for monoclonal-based ELISA (R = 0.819; n = 40). These data show that the generated antibodies may be used as functional analytical reagents for the integration into multianalyte biochip detection systems.
The recently instituted and easily accessible Rapid Alert System for Food and Feed (RASFF) has been tested on the semicarbazid (SEM), the residue of veterinary antibiotic nitrofurazone, using the RASFF Database Portal launched in July 2009 by the European Commission. The database holds weekly overviews, published by the EU for 30 years from 1979 and offers a number of other possibilities, such as searching for subjects of notification, the date of notification, notifying countries and product categories, countries of product origin and distribution. There is no doubt that the new database portal is an important contribution of the European Union to food safety and consumer protection.
An improved LC-MS/MS method for the determination of semicarbazide in whole egg is described. Waters OASIS-MCX cation exchange purification cartridges increased the sensitivity for analysis by LC-MS/MS. The validation study was carried out according to criteria and requirements of Commission Decision 2002/657/EC for confirmatory analysis and provided the data as follows: The correlation coefficient for the matrix calibration curve, in the range of 0–5μgkg−1, was r=0.9968. The detection capability and decision limit, measured according to ISO11843-2, were CCα=0.20μgkg−1 and CCβ=0.25μgkg−1. Repeatability (CVSr) and within-laboratory reproducibility (CVSwr) determined for the concentration levels of 0.2, 0.5 and 1.0μgkg−1 SEM ranged from 11.9 to 5.7% and 11.8 to 6.3%, respectively. The validated method was applied to investigate SEM stability in incurred materials (egg homogenates) during long-term storage at −20°C and 4°C. The study proved by a two-sampling test that SEM at levels of 17. 7, 1.2, 10.6 and 0.47μgkg−1 was stable for up to 12 months.
Many bioanalytic and diagnostic procedures rely on labels with which the molecule of interest can be tracked in or discriminated from accompanying like substances. Herein, we describe a new labeling and detection system based on derivatives of 2,4-dichlorophenoxyacetic acid (2,4-D) and anti-2,4-D antibodies. The 2,4-D system is highly sensitive with a K(D) of 7 x 10(-11) M for the hapten-antibody pair, can be used on a large variety of biomolecules such as proteins, peptides, carbohydrates, and nucleic acids, is not hampered by endogenous backgrounds because 2,4-D is a xenobiotic, and is robust because 2,4-D is a very stable compound that withstands the conditions of most reactions usually performed on biomolecules. With this unique blend of properties, the 2,4-D system compares favorably with its rivals digoxigenin (DIG)/anti-DIG and biotin/(strept)avidin and provides an interesting and powerful tool in biomolecular labeling.