Results of 150 arthroscopic partial medial meniscectomies were analyzed by computer to identify the factors that lead to an unsatisfactory (fair or poor) outcome. The average follow-up for the group was 36 months (range 24-60 months). One-hundred ten men and 40 women were involved, with an average age of 48 years. The overall results were 58% excellent-good, 28% fair, and 14% poor. Most tears involved the posterior horn (76%). Bucket handle, longitudinal, and flap tears were rated 88% excellent-good, whereas horizontal cleavage and degenerative and complex tears had only 45% excellent-good scores. The results were adversely affected by the severity of the chondromalacia, work-related injury, prior knee surgery, simultaneous lateral meniscectomy, and increased knee laxity. Because degenerative posterior horn tears had such a high percentage of unsatisfactory results, the question remains as to whether all these tears need to be removed.
A specific pattern of injury to the superior labrum of the shoulder was identified arthroscopically in twenty-seven patients included in a retrospective review of more than 700 shoulder arthroscopies performed at our institution. The injury of the superior labrum begins posteriorly and extends anteriorly, stopping before or at the mid- glenoid notch and including the "anchor" of the biceps tendon to the labrum. We have labeled this injury a "SLAP lesion" (Superior Labrum Anterior and Posterior). There were 23 males and four females with an average age of 37.5 years. Time from injury to surgery averaged 29.3 months. The most common mechanism of injury was a compression force to the shoulder, usually as the result of a fall onto an outstretched arm, with the shoulder positioned in abduction and slight forward flexion at the time of the impact. The most common clinical complaints were pain, greater with overhead activity, and a painful "catching" or "popping" in the shoulder. No imaging test accurately defined the superior labral pathology preoperatively. We divided the superior labrum pathology into four distinct types. Treatment was performed arthroscopically based on the type of SLAP lesion noted at the time of surgery. The SLAP lesion, which has not been previously described, can be diagnosed only arthroscopically and may be treated successfully by arthroscopic techniques alone in many patients.
The UniSpacer is made by Centerpulse and is a 1-piece nonfixed cobalt-chrome device to be inserted on the medial aspect of the medial knee, similar to previous Macintosh and McKeever prostheses. It differs primarily in the fact that it has 6 sizes, attempting to conform to the medial femur on the top, with the bottom being flat. It was developed by an orthopedist, Dr. Rick Hallock, and Barry Fell, an engineer. As of this date, 3,250 total procedures have been performed. The first was performed in October 2000. The company is training 40 orthopedists per month in this technique.
Arthroscopy: The Journal of Arthroscopic and Related Surgery, Vol 18, No 2 (February, Suppl 1), 2002: pp 33–39
PURPOSE:The use of blunt-threaded titanium interference screws for arthroscopic-assisted fixation of a quadruple-strand hamstring anterior cruciate ligament (ACL) reconstruction has recently been reported. However, the pitfalls of the low medial portal technique, rehabilitation protocol, and long-term results have not. The purpose of this multicenter study was to prospectively evaluate this technique's application to ACL instability in symptomatic patients as well as to develop a standardized rehabilitation protocol.TYPE OF STUDY:Observation cohort study.METHODS:One hundred-twenty patients had quadruple hamstring ACL reconstructions, followed the study protocol, and were seen at 2 years follow-up. They were evaluated using Lysholm score, Lachman test, anterior drawer test, pivot-shift test, KT-1000, effusion assessment, and the Tegner Sports Activity Scale.RESULTS:The average Lysholm score improved 42 points; Lachman test, effusion assessment, anterior drawer test, KT-1000, and Tegner Sports Activity Scale scores all improved. Of 120 ACL reconstructions, 5 failed. Of these, 3 failed from new late injury, 1 from technical error, and 1 from patient nonadherence to rehabilitation protocol. Some anterior knee pain was present in 30% of patients, and 22% had at some time experienced hamstring pain that did not interfere with athletic activity.CONCLUSIONS:This multicenter study reports success with quadruple hamstring ACL reconstruction using the low medial portal technique. Specific pitfalls and a rehabilitation protocol are also discussed. Low medial portal position is critical in successful surgery. Variations in screw size to accommodate the variation in graft construct size are also recommended.
The records of 234 people who had anteromedializa tion of the tibial tubercle with oblique osteotomy be tween 1983 and 1994 at two separate institutions were reviewed retrospectively. Six patients (2.6%) had frac tures of the proximal tibia postoperatively, within 13 weeks of the Fulkerson osteotomy. All fractures oc curred after a change in the postoperative physical therapy regimen from partial weightbearing to immedi ate full weightbearing. All fractures healed with accept able alignment of less than 5° of varus-valgus or an teroposterior angulation. Given this increase in fracture incidence, a more conservative postoperative physical therapy regimen is recommended. All patients should be nonweightbearing initially, advanced gradually to partial weightbearing, and allowed full weightbearing only after the osteotomy has radiographic evidence of complete healing.
Intraarticular reconstruction of the anterior cruciate ligament (ACL) requires anatomical placement of the graft for best results. The grafts that are commonly used in ACL reconstruction include the patellar tendon, semitendinosus tendon, and gracilis tendon, as well as allografts. The surgical technique and graft choices for ACL reconstruction should be selected after careful consideration of the patients’ age, size, level of activity, and degree of functional instability. A semitendinosus/gracilis tendon reconstruction should be considered in those patients who have an acute injury, mild to moderate laxity, or a significant history of patellofemoral symptoms. This chapter discusses the reasons to consider an ACL reconstruction using a hamstring graft as well as the surgical technique and results.
Magnetic resonance (MR) imaging is contraindicated for patients with certain ferromagnetic implants, primarily because of potential risks related to movement or dislodgment of the devices. An additional problem with metallic implants is the potential image distortion that may affect the interpretation of the MR study. Since MR imaging is frequently useful for the evaluation of postoperative anterior cruciate ligament (ACL) reconstruction, the ferromagnetic qualities and artifacts associated with MR imaging were determined for five metallic orthopedic implants commonly used for this surgery. Only the Perfix interference screw displayed a substantial deflection force and caused extensive signal loss. Images of the knee of one patient with two Perfix screws in place were not interpretable because of the image distortion caused by these implants. Therefore, alternative nonferromagnetic implants should be considered for reconstruction of the ACL.
Numerous procedures and various natural and synthetic materials have been used to reconstruct the anterior cruciate ligament-deficient knee. Although the patellar tendon autograft seems to be the most commonly used substitute, techniques incorporating the pes tendons, iliotibial band, and meniscus have been described. Allografts and prosthetic ligaments are still being investigated, and, at the present time, the indications for their use may be limited.
Fifteen chronic anterior cruciate ligament-deficient knees were arthroscopically reconstructed with a semitendinosus tendon polypropylene (STP) augmented composite graft. A comparison group of 28 reconstructions with the semitendinosus tendon (ST) but without augmentation was simultaneously reviewed. The mean follow-up in the STP group was 31 months (range of 24-42 months) and in the ST group it was 34 months (range 26-54 months). Both patient groups had similar age, sex, preinjury functional sports level, injury-to-surgery interval, and associated meniscal pathology. Good-to-excellent subjective results were reported in 86% of STP patients and 78% of ST patients, whereas 86% of the STP patients and 88% of the ST patients returned to sports activity. Objective examination revealed 73% of the STP group and 82% of the ST group to have a negative or 1+ Lachman test result. A negative pivot shift was noted at follow-up in 80% of the STP group and in 82% of the ST group. KT-1000 testing revealed 60% of the STP patients and 61% of the ST patients to have less than or equal to 3 mm of side-to-side difference. In the STP group there was no evidence of graft breakage, deep infections, or sterile effusions. Overall subjective and functional results were uniformly better than objective results in both patient groups. Analysis of subjective, objective, and functional results reveal no difference in outcome between the STP and the ST patient groups.
Magnetic resonance images of the knee were made for 1014 patients, and the diagnosis was subsequently confirmed arthroscopically. The accuracy of the diagnoses from the imaging was 89 per cent for the medial meniscus, 88 per cent for the lateral meniscus, 93 per cent for the anterior cruciate ligament, and 99 per cent for the posterior cruciate ligament. The magnetic resonance examinations were done at several centers, and the results varied substantially among centers. The accuracy ranged from 64 to 95 per cent for the medial meniscus, from 83 to 94 per cent for the lateral meniscus, and from 78 to 97 per cent for the anterior cruciate ligament. The results from different magnetic-resonance units were also compared, and the findings suggested increased accuracy for the units that had a stronger magnetic field. Of the menisci for which the magnetic resonance signal was reported to be Grade II (a linear intrameniscal signal not extending to the superior or inferior meniscal surface), 17 per cent were found to be torn at arthroscopy.
We studied 31 patients (17 females, 14 males; average age, 34) with more than 2 years of followup who had chronic anterolateral ankle pain following inversion injury. All had failed to respond to at least 2 months of conservative treatment and had negative stress radiographs to rule out instability. On physical examination, tenderness was localized to the anterolateral corner of the talar dome. Magnetic resonance imaging was the most useful diagnostic screening test, showing synovial thickening consistent with impingement in the anterolateral gutter. At an average of 24 months after injury, all patients underwent ankle arthroscopy, which showed proliferative synovitis and fibrotic scar tissue in the lateral gutter, often with associated chondromalacia of the talus. Operative arthroscopic treatment consisted of partial synovectomy with debridement of scar tissue from the lateral gutter. Postoperatively, patients walked with crutches allowing weightbearing as tolerated. Average return to sports was 6 weeks. Histopathologic analysis performed on the resected tissue showed synovial changes consistent with chronic inflammation. Results of treatment after at least 2 year followup were 15 excellent, 11 good, 4 fair, and 1 poor. Since there are several distinct causes of chronic ankle pain, we prefer to call this problem "anterolateral impingement of the ankle" and believe the term "chronic sprain pain" should be discarded.
Spontaneous osteonecrosis about the knee typically is a disease of the elderly characterized by an acute onset of pain. The exact cause of this condition has long been debated, although a causative relationship between meniscal tears and spontaneous osteonecrosis about the knee has been postulated. Seven patients with knee pain, meniscal tears, and chondromalacia without initial evidence of osteonecrosis at magnetic resonance (MR) imaging underwent arthroscopic surgery with meniscal recontouring or repair and cartilage shaving. These patients returned within 2-14 months with recurrent pain in the treated knee. MR imaging then demonstrated abnormalities consistent with osteonecrosis. Osteonecrosis of the femoral condyle or tibial plateau may be a late sequela of meniscal injury in association with chondromalacia and arthroscopic surgery. This diagnosis should be suspected in patients with recurrent knee pain after arthroscopic repair of meniscal tears. The precise relationship of this pattern of osteonecrosis to that previously described as spontaneous requires further investigation.
1. All synthetic anterior cruciate ligaments can be divided into three broad categories--permanent, stent, and ingrowth. 2. Theoretical advantages (e.g., potential increased strength, decreased harvest morbidity, time to return to sport, ease of insertion, ease of revision) warrant further attempts to develop synthetic ACLs. 3. Permanent ACLs require 5-year follow-up. Gore-Tex I had 85% to 90% good to excellent results at 2 years. 4. Acceptable failure rates for permanent prosthesis (5 years? 10 years?) should be discussed. 5. Gore-Tex II will represent a significant improvement to Gore-Tex I (increased abrasion resistance). 6. Prosthetic debris and effusions should continue to be analyzed carefully. Dr. Freddie Fu's protocol for retrieval and analysis should be accepted and standardized. 7. LAD. Careful analysis of the control group in U.S. Series II should enable us to determine the "true" contribution of this augmentation device. 8. Leeds-Keio. If biomechanically significant intra-articular tissue is stimulated, this is a potentially attractive prosthetic concept. U.S. clinical studies will start in 1990. 9. Stryker-Dacron. This device appears to have a failure rate similar to that of Gore-Tex I. 10. Six new prosthetic devices are currently under evaluation by the FDA and are in phases I through V.
Magnetic resonance images of the knee were made for 1014 patients, and the diagnosis was subsequently confirmed arthroscopically. The accuracy of the diagnoses from the imaging was 89 per cent for the medial meniscus, 88 per cent for the lateral meniscus, 93 per cent for the anterior cruciate ligament, and 99 per cent for the posterior cruciate ligament. The magnetic resonance examinations were done at several centers, and the results varied substantially among centers. The accuracy ranged from 64 to 95 per cent for the medial meniscus, from 83 to 94 per cent for the lateral meniscus, and from 78 to 97 per cent for the anterior cruciate ligament. The results from different magnetic-resonance units were also compared, and the findings suggested increased accuracy for the units that had a stronger magnetic field. Of the menisci for which the magnetic resonance signal was reported to be Grade II (a linear intrameniscal signal not extending to the superior or inferior meniscal surface), 17 per cent were found to be torn at arthroscopy.
Thirty-one patients with arthroscopically documented partial thickness rotator cuff tears treated by arthroscopic debridement of the lesion were retrospectively reviewed. The patients had had symptoms for an average of 20.5 months prior to surgery. Twenty-two of these 31 shoulders also had bursoscopy, with 18 having arthroscopic subacromial decompression. The results were graded by both the UCLA Shoulder Rating Scale and Neer's criteria. Twenty-six (84%) of the patients had satisfactory results with the remaining 5 (16%) patients having unsatisfactory results. A classification system for the size and location of partial thickness rotator cuff tears is presented. The lesion size did not affect the result. Repeat arthroscopy in three patients demonstrated no further deterioration of their rotator cuff. The results with and without subacromial decompression were similar. The need for subacromial decompression is best determined by the arthroscopic finding of a bursal side tear.