Purpose: Proton radiotherapy (PRT) is potentially associated with a lower risk for secondary malignancies due to a decreased integral dose to the surrounding organs at risk (OARs). Prospective trials confirming this are lacking due to the need for long-term follow-up and the ethical complexities of randomizing patients between modalities. The objective of the current study is to calculate the risk for secondary malignancies following PRT and photon-based intensity-modulated radiotherapy (IMRT). Materials and Methods: Twenty-three patients (16 female and seven male), previously treated with active scanning PRT for malignant mediastinal lymphoma at Heidelberg Ion Beam Therapy Center, were retrospectively re-planned using helical photon IMRT. The risk for radiation-induced secondary malignancies was estimated and evaluated using two distinct prediction models (1–4). Results: According to the Dasu model, the median absolute total risk for tumor induction following IMRT was 4.4% (range, 3.3–5.8%), 9.9% (range, 2.0–27.6%), and 1.0% (range, 0.5–1.5%) for lung, breast, and esophageal cancer, respectively. For PRT, it was significantly lower for the aforementioned organs at 1.6% (range, 0.7–2.1%), 4.5% (range, 0.0–15.5), and 0.8% (range, 0.0–1.6%), respectively (p ≤ 0.01). The mortality risk from secondary malignancies was also significantly reduced for PRT relative to IMRT at 1.1 vs. 3.1% (p ≤ 0.001), 0.9 vs. 1.9% (p ≤ 0.001), and 0.7 vs. 1.0% (p ≤ 0.001) for lung, breast, and esophageal tumors, respectively. Using the Schneider model, a significant risk reduction of 54.4% (range, 32.2–84.0%), 56.4% (range, 16.0–99.4%), and 24.4% (range, 0.0–99.0%) was seen for secondary lung, breast, and esophageal malignancies, favoring PRT vs. X-ray-based IMRT (p ≤ 0.01). Conclusion: Based on the two prediction models, PRT for malignant mediastinal lymphoma is expected to reduce the risk for radiation-induced secondary malignancies compared with the X-ray-based IMRT. The young age and the long natural history of patients diagnosed with mediastinal lymphoma predisposes them to a high risk of secondary malignancies following curative radiotherapy treatment and, as a consequence, potentially reducing this risk by utilizing advanced radiation therapy techniques such as PRT should be considered.
Irradiation therapy limits the utilization of silicone implants for breast reconstruction due to a significant risk for capsular contracture. The injection of the collagenase of the bacterium Clostridium histolyticum (CCH) might trivialize this risk by providing a minimal-invasive treatment option by capsular contracture degradation. However, efficacy in degrading breast implant capsules induced by fractionated irradiation remains unclear. Twenty-four rats in three groups received miniature silicone implants in a submuscular pocket. After 3D dose calculation and treatment field definition, rats of two groups underwent fractionated radiotherapy (6 × 8 Gy) using a linear accelerator. A third group served as control. On day 120, one irradiated group received injections of 0.3 mg/ml collagenase. Administration of plain solvent solution served as control in the two other groups. Outcome parameters included CT-imaging, histology, vessel wall analysis, immunohistochemistry, chemical collagen quantification and gene expression analysis. Fractioned irradiation leads to a significant increase in collagen deposition around silicone implants with higher capsule thickness and collagen density when comparing all groups. Additionally, significant alterations of collagen fiber deposition were evident. Vessel wall thickness was significantly increased after radiotherapy. The injection of collagenase led to a significant reduction of capsule thickness, collagen density and content. However, the collagenase application induced a significant overexpression of TGFβ1. No side effects were monitored. The CCH proved to be a safe and effective approach to degrade capsule tissue induced by fractionated irradiation in an animal model. This may pave its way for clinical application in implant-based breast reconstruction patients. This journal requires that authors assign a level of evidence to each submission to which Evidence-Based Medicine rankings are applicable. This excludes Review Articles, Book Reviews, and manuscripts that concern Basic Science, Animal Studies, Cadaver Studies, and Experimental Studies. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.springer.com/00266 .
Purpose To evaluate the potential of cone-beam-CT (CB-CT) guided adaptive radiotherapy (ART) for locally advanced non-small cell lung cancer (NSCLC) for sparing of surrounding organs-at-risk (OAR). Materials and Methods In 10 patients with locally advanced NSCLC, daily CB-CT imaging was acquired during radio- (n = 4) or radiochemotherapy (n = 6) for simulation of ART. Patients were treated with conventionally fractionated intensity-modulated radiotherapy (IMRT) with total doses of 60–66 Gy (pPlan) (311 fraction CB-CTs). OAR were segmented on every daily CB-CT and the tumor volumes were modified weekly depending on tumor changes. Doses actually delivered were recalculated on daily images (dPlan), and voxel-wise dose accumulation was performed using a deformable registration algorithm. For simulation of ART, treatment plans were adapted using the new contours and re-optimized weekly (aPlan). Results CB-CT showed continuous tumor regression of 1.1 ± 0.4% per day, leading to a residual gross tumor volume (GTV) of 65.3 ± 13.4% after 6 weeks of radiotherapy (p = 0.005). Corresponding PTVs decreased to 83.7 ± 7.8% (p = 0.005). In the actually delivered plans (dPlan), both conformity (p = 0.005) and homogeneity (p = 0.059) indices were impaired compared to the initial plans (pPlan). This resulted in higher actual lung doses than planned: V20Gy was 34.6 ± 6.8% instead of 32.8 ± 4.9% (p = 0.066), mean lung dose was 19.0 ± 3.1 Gy instead of 17.9 ± 2.5 Gy (p = 0.013). The generalized equivalent uniform dose (gEUD) of the lung was 18.9 ± 3.1 Gy instead of 17.8 ± 2.5 Gy (p = 0.013), leading to an increased lung normal tissue complication probability (NTCP) of 15.2 ± 13.9% instead of 9.6 ± 7.3% (p = 0.017). Weekly plan adaptation enabled decreased lung V20Gy of 31.6 ± 6.2% (−3.0%, p = 0.007), decreased mean lung dose of 17.7 ± 2.9 Gy (−1.3 Gy, p = 0.005), and decreased lung gEUD of 17.6 ± 2.9 Gy (−1.3 Gy, p = 0.005). Thus, resulting lung NTCP was reduced to 10.0 ± 9.5% (−5.2%, p = 0.005). Target volume coverage represented by conformity and homogeneity indices could be improved by weekly plan adaptation (CI: p = 0.007, HI: p = 0.114) and reached levels of the initial plan (CI: p = 0.721, HI: p = 0.333). Conclusion IGRT with CB-CT detects continuous GTV and PTV changes. CB-CT-guided ART for locally advanced NSCLC is feasible and enables superior sparing of healthy lung at high levels of plan conformity.
Background To investigate deviations between planned and applied treatment doses for hypofractionated prostate radiotherapy and to quantify dosimetric accuracy in dependence of the image guidance frequency. Methods Daily diagnostic in-room CTs were carried out in 10 patients in treatment position as image guidance for hypofractionated prostate radiotherapy. Fraction doses were mapped to the planning CTs and recalculated, and applied doses were accumulated voxel-wise using deformable registration. Non-daily imaging schedules were simulated by deriving position correction vectors from individual scans and used to rigidly register the following scans until the next repositioning before dose recalculation and accumulation. Planned and applied doses were compared regarding dose-volume indices and TCP and NTCP values in dependence of the imaging and repositioning frequency. Results Daily image-guided repositioning was associated with only negligible deviations of analyzed dose-volume parameters and conformity/homogeneity indices for the prostate, bladder and rectum. Average CTV T did not significantly deviate from the plan values, and rectum NTCPs were highly comparable, while bladder NTCPs were reduced. For non-daily image-guided repositioning, there were significant deviations in the high-dose range from the planned values. Similarly, CTV dose conformity and homogeneity were reduced. While TCPs and rectal NTCPs did not significantly deteriorate for non-daily repositioning, bladder NTCPs appeared falsely diminished in dependence of the imaging frequency. Conclusion Using voxel-by-voxel dose accumulation, we showed for the first time that daily image-guided repositioning resulted in only negligible dosimetric deviations for hypofractionated prostate radiotherapy. Regarding dosimetric aberrations for non-daily imaging, daily imaging is required to adequately deliver treatment.
Background and purpose: To analyze divergences between the planned and applied treatment doses for post-prostatectomy radiotherapy to the prostatic fossa on a voxel-by-voxel basis based on interfractional anatomic variations and imaging frequency. Materials and methods: For 10 patients receiving intensity-modulated postoperative radiotherapy to the prostatic fossa, position verification was carried out by daily in-room CT imaging in treatment position (340 fraction CTs). Applied fraction doses were recalculated on daily CT scans, and treatment doses were accumulated on a voxel-by-voxel basis after deformable image registration. To simulate weekly imaging, derived weekly position correction vectors were used to rigidly register all daily scans of the respective treatment week onto the planning CT before dose accumulation. Detailed dose statistics of the prescribed and applied treatment doses were compared in relation to the frequency of position verification imaging. Derived NTCP and P-injury values were calculated for the rectum and bladder. Results: Despite a large variability in the pelvic anatomy, daily CT-based patient repositioning resulted in largely negligible deviations of the analyzed dose-volume, conformity, and uniformity parameters from the planned doses for post-prostatectomy radiotherapy, and only the bladder exhibited significant increases in the accumulated mean and median doses. Derived NTCP for the applied doses to the rectum and bladder and P-injury values did not significantly deviate from the treatment plan. In contrast, weekly CT-based repositioning resulted in significant decreases of the PTV coverage and dose conformity as well as large deviations of the applied doses to the rectum and bladder from the planned doses. Consecutively, NTCP for the rectum and P-injury were found falsely reduced for weekly patient repositioning. Conclusions: Our data indicate for the first time in a voxel-by-voxel analysis that daily imaging is required for reliable adaptive delivery of intensity-modulated radiotherapy to the prostatic fossa. This work will help guiding adaptive treatment strategies for post-prostatectomy radiotherapy.
The present work aimed to analyze the feasibility of a shuttle-based MRI-guided radiation therapy (MRgRT) in the treatment of pelvic malignancies.