The aCORN experiment measures the electron-antineutrino $a$-coefficient in free neutron decay. We update the previous aCORN results to include radiative and recoil corrections to first order, and discuss a key issue in the comparison of results from different $a$-coefficient experimental methods when these effects are considered. The corrected combined result is $\overline{a} = -0.10779 \pm 0.00125\, ({\rm stat}) \pm 0.00133\, ({\rm sys})$, averaged over the full Fermi neutron beta spectrum. The corresponding corrected result for the ratio of weak coupling constants $\lambda = G_A/G_V$ is $\lambda = -1.2712 \pm 0.0061$. This improves agreement with previous $a$-coefficient experiments, in particular the 2020 aSPECT result
We respond to issues raised by Serebrov et al. in a recent paper regarding systematic effects in the beam neutron lifetime experiment performed at NIST. We show that these effects were considered in the original analyses and that our corrections and systematic uncertainties were appropriate. We point out some misunderstandings in the analysis of Serebrov et al. None of the issues raised lead us to alter the value of the neutron lifetime reported.
We discuss issues raised by Serebrov, et al. in a recent paper regarding systematic effects in the beam neutron lifetime experiment performed at NIST. We show that these effects were considered in the original analyses and that our corrections and systematic uncertainties were appropriate. We point out some misconceptions and erroneous assumptions in the analysis of Serebrov, et al. None of the issues raised in Serebrov, et al lead us to alter the value of the neutron lifetime reported previously.
Nuclear physics has long played a central role in our efforts to better understand the natural world. Several experiments are currently well positioned to improve limits in searches for physics Beyond the Standard Model (BSM). Many experiments in nuclear physics have traditionally used semiconductor or scintillation detectors for particle detection, yet these face fundamental performance limitations that greatly restrict the sensitivity achievable. A new detector paradigm for charged particle detection could potentially open up orders of magnitude improvement in sensitivity in searches for BSM physics. We are working to achieve this by adapting Thermal Kinetic Inductance Detectors (TKIDs) for external charged particle detection. These cryogenic detectors are used in X-ray and gamma spectroscopy as well as dark matter searches and have been shown to have photon energy resolutions on the order of tens of eV. They can be multiplexed to create large area detectors. Thus far, however, TKIDs have not yet been developed for external (non-embedded) charged particle detection. Creating a TKID with a sensitivity of 100s of eV or better suitable for external charged particle detection would significantly impact the next generation of nuclear experiments, allowing orders of magnitude improvements in sensitivity.
The neutron polarization of the NG-C beamline at the NIST Center for Neutron Research was measured as part of the aCORN neutron beta decay experiment. Neutron transmission through a polarized 3He spin filter cell was recorded while adiabatic fast passage (AFP) nuclear magnetic resonance (NMR) reversed the polarization direction of the 3He in an eight-step sequence to account for drifts. The dependence of the neutron transmission on the spin filter direction was used to calculate the neutron polarization. The time dependent transmission was fit to a model which included the neutron spectrum, and 3He polarization losses from spin relaxation and AFP-NMR. The neutron polarization averaged over the spectrum of the NG-C beam was found to be P n ≤ 4 × 10 - 4 with 90 % confidence.
The aCORN experiment measures the neutron-decay electron-antineutrino correlation (a coefficient) using a novel method based on an asymmetry in proton time-of-flight for events where the beta electron and recoil proton are detected in delayed coincidence. We report the data analysis and result from the second run at the NIST Center for Neutron Research, using the high-flux cold neutron beam on the new NG-C neutron guide end position: a = -0.10758 +/- 0.00136(stat) +/- 0.00148(sys). This is consistent within uncertainties with the result from the first aCORN run on the NG-6 cold neutron beam. Combining the two aCORN runs, we obtain a = -0.10782 +/- 0.00124(stat) +/- 0.00133(sys), which has an overall relative standard uncertainty of 1.7%. The corresponding result for the ratio of weak coupling constants lambda = G(A)/G(V) is lambda = -1.2796 +/- 0.0062.
We comment on a recent manuscript by A. P. Serebrov, et al. regarding residual gas charge exchange in the beam neutron lifetime experiment
The breadth of experiments performed using slow neutrons continues to increase worldwide.The accomplishments are a result of strong collaborations among national laboratories and university-based scientists and their students.There have been a growing number of notable results in fundamental neutron physics over the course of the last three-year grant period.A number of these experiments have been carried out on the beamlines at NIST or with the participation of NIST researchers.The list below gives a brief summary of some of these results as well as some of the cooperative endeavors during the last grant period.
The Alpha-Gamma device at the National Institute of Standards and Technology (NIST) utilizes neutron capture on a totally absorbing 10B deposit to measure the absolute neutron flux of a monochromatic cold neutron beam. Gammas produced by the boron capture are counted using high purity germanium detectors, which are calibrated using a well-measured 239Pu alpha source and the alpha-to-gamma ratio from neutron capture on a thin 10B target. This device has been successfully operated and used to calibrate the neutron flux monitor for the BL2 neutron lifetime experiment at NIST. It is also being used for a measurement of the 6Li(n,t)4He cross section. We shall present its principle of operation along with the current and planned projects involving the Alpha-Gamma device, including the recalibration of the U.S. national neutron standard NBS-1 and (n,f) cross section measurements of 235U.
The NBS-1 photo-neutron source is the primary standard for neutron calibrations in the United States of America. The source is constructed from 1 g of radium in a RaBr2 salt contained in a Pt-Ir capsule located in the geometric center of a 4 cm beryllium sphere. Since the source was fabricated in 1949, it is desirable to determine the integrity of the capsule and current geometry of the radium salt. Several challenges are presented in inspecting the source such as the high-Z materials used for the capsule which make X-ray tomography challenging with lower keV generators and the radioactive material which creates an intense neutron and gamma radiation fields. The radiation emitted from the source makes it impractical to move the source to a capable imaging facility and makes it difficult to work with as it is not possible to handle directly. To overcome these issues and allow for a feasibility study, a dummy source has been constructed using PbBr2 powder. This talk will provide background on the dummy source and the results of the feasibility study to determine if it possible to relocate a current X-ray system to the neutron calibration facility to inspect the NBS-1 source.
The aCORN experiment uses a novel asymmetry method to measure the electron-antineutrino correlation (a-coefficient) in free neutron decay that does not require precision proton spectroscopy. aCORN completed two physics runs at the NIST Center for Neutron Research. The first run on the NG-6 beam line obtained the result a = 0.1090 +/- 0.0030 (stat) +/- 0.0028 (sys), the most precise to date. The second run on the new NG-C high flux beam line promises an improvement in precision to ¡ 2%. In addition we show that an improved measurement of the neutrino asymmetry (B-coefficient) can be made using the aCORN apparatus on a highly polarized neutron beam.
A precise value of the neutron lifetime is important in several areas of physics, including determinations of the quark-mixing matrix element │Vud│, related tests of the Standard Model, and predictions of light element abundances in Big Bang Nucleosynthesis models. We report the progress on a new measurement of the neutron lifetime utilizing the cold neutron beam technique. Several experimental improvements in both neutron and proton counting that have been developed over the last decade are presented. This new effort should yield a final uncertainty on the lifetime of 1 s with an improved understanding of the systematic effects.
The aCORN experiment uses a novel asymmetry method to measure the electron-antineutrino correlation (a-coefficient) in free neutron decay that does not require precision proton spectroscopy. aCORN completed two physics runs at the NIST Center for Neutron Research. The first run on the NG-6 beam line in 2013--2014 obtained the result a = 0.1090 +/- 0.0030 (stat) +/- 0.0028 (sys), a total uncertainty of 3.8%. The second run on the new NG-C high flux beam line promises an improvement in precision to <2%.
A technique for establishing the total neutron rate of a highly-collimated monochromatic cold neutron beam was demonstrated using an alpha-gamma counter. The method involves only the counting of measured rates and is independent of neutron cross sections, decay chain branching ratios, and neutron beam energy. For the measurement, a target of 10B-enriched boron carbide totally absorbed the neutrons in a monochromatic beam, and the rate of absorbed neutrons was determined by counting 478 keV gamma rays from neutron capture on 10B with calibrated high-purity germanium detectors. A second measurement based on Bragg diffraction from a perfect silicon crystal was performed to determine the mean de Broglie wavelength of the beam to a precision of 0.024%. With these measurements, the detection efficiency of a neutron monitor based on neutron absorption on 6Li was determined to an overall uncertainty of 0.058%. We discuss the principle of the alpha-gamma method and present details of how the measurement was performed including the systematic effects. We also describe how this method may be used for applications in neutron dosimetry and metrology, fundamental neutron physics, and neutron cross section measurements.
We describe an apparatus used to measure the electron-antineutrino angular correlation coefficient in free neutron decay. The apparatus employs a novel measurement technique in which the angular correlation is converted into a proton time-of-flight asymmetry that is counted directly, avoiding the need for proton spectroscopy. Details of the method, apparatus, detectors, data acquisition, and data reduction scheme are presented, along with a discussion of the important systematic effects.
We report the first result for the electron-antineutrino angular correlation (a coefficient) in free neutron β decay from the aCORN experiment. aCORN uses a novel method in which the a coefficient is proportional to an asymmetry in proton time of flight for events where the β electron and recoil proton are detected in delayed coincidence. Data are presented from a 15 month run at the NIST Center for Neutron Research. We obtained a=-0.1090±0.0030(stat)±0.0028(sys), the most precise measurement of the neutron a coefficient reported to date.
Backscatter of electrons from a beta spectrometer, with incomplete energy deposition, can lead to undesirable effects in many types of experiments. We present and discuss the design and operation of a backscatter-suppressed beta spectrometer that was developed as part of a program to measure the electronantineutrino correlation coefficient in neutron beta decay (aCORN). An array of backscatter veto detectors surrounds a plastic scintillator beta energy detector. The spectrometer contains an axial magnetic field gradient, so electrons are efficiently admitted but have a low probability for escaping back through the entrance after backscattering. The design, construction, calibration, and performance of the spectrometer are discussed.
In experiments that measure the lifetime of trapped particles, in addition to loss mechanisms with exponential survival probability functions, particles can be lost by mechanisms with non-exponential survival probability functions. Failure to account for such loss mechanisms produces systematic measurement error and associated systematic uncertainties in these measurements. In this work, we develop a general competing risks survival analysis method to account for the joint effect of loss mechanisms with either exponential or non-exponential survival probability functions, and a method to quantify the size of systematic effects and associated uncertainties for lifetime estimates. As a case study, we apply our survival analysis formalism and method to the Ultra Cold Neutron lifetime experiment at NIST. In this experiment, neutrons can escape a magnetic trap before they decay due to a wall loss mechanism with an associated non-exponential survival probability function. Published by Elsevier B.V.